MagVenture Accessories Catalogue - Roxon

MagVenture Accessories Catalogue - Roxon MagVenture Accessories Catalogue - Roxon

13.07.2015 Views

Magnetic Stimulation Accessories CatalogueMCF-P-B65 Placebo Butterfly Coil• The coil's magnetic shield provides a fieldreduction of approximately 80%.• The Placebo Coil has a mechanical outlineand sound level identical to MCF-B65.• With a reduction of stimulus intensity with20-25% the coil can perform the samenumber of stimulations as the normalMCF-B65.• Equipped with trigger button to supportclinical operation.Mechanical PropertiesWeight of transducer head 2.9kgCable length2mDimensions of transducer head 174 x 94 x 53 mmCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)PerformanceNumber of stimulations before 1600 pulseswarm-up at ambient temperature20°C:Mean output 75% of maximumat 1pps.Ordering Number 9016E060-34 www.MagVenture.com

Magnetic Stimulation Accessories CatalogueCool-B65 A/P Butterfly Coil• The Cool-B65-A/P Coil is designed foradvanced clinical studies where doubleblinded research experiments are required.• The Cool-B65-A/P functions both as anactive (A) coil and as a placebo (P) coil.• The Cool-B65-A/P has a symmetricalmechanical design and no labeling on thecoil indicates the active or placebo side.Consequently it is not possible for theoperator to see or hear which side is used.• The coil has electrical and magneticproperties identical to the MCF-B65 andCool-B65.• Built-in orientation switch to determinewhich side the operator shall directtowards the patient.• For use only with MagVenture rTMSResearch software (MagLink).• Adjustable output for current stimulationsurface electrodes enables skin stimulationto occur synchronously with the magneticstimulation pulse• Built in timer and counter with presetoperating period (days and stimulations)• Includes Stimulator Electrode Cable andone pack of Surface Electrodes (12pcs.)Mechanical PropertiesWeight of transducer head 3kgCable length 1.3mDimensions of transducer 174 x 94 x 80 mmheadCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt Max initial dB/dt: 36 kT/s near thecoil surface on the active side,same as Cool-B65 Coil.The magnetic field near the coilsurface on the placebo side isreduced to 20.000 pulseswarm-up at ambienttemperature 20°C:Mean output 100% ofmaximum at 2pps.Number of stimulations, beforewarm-up at ambienttemperature 20°C withprotocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval:25s @ Output=75%.>10.000 pulsesOrdering Number 9016E050-www.MagVenture.com 35

Magnetic Stimulation <strong>Accessories</strong> <strong>Catalogue</strong>Cool-B65 A/P Butterfly Coil• The Cool-B65-A/P Coil is designed foradvanced clinical studies where doubleblinded research experiments are required.• The Cool-B65-A/P functions both as anactive (A) coil and as a placebo (P) coil.• The Cool-B65-A/P has a symmetricalmechanical design and no labeling on thecoil indicates the active or placebo side.Consequently it is not possible for theoperator to see or hear which side is used.• The coil has electrical and magneticproperties identical to the MCF-B65 andCool-B65.• Built-in orientation switch to determinewhich side the operator shall directtowards the patient.• For use only with <strong>MagVenture</strong> rTMSResearch software (MagLink).• Adjustable output for current stimulationsurface electrodes enables skin stimulationto occur synchronously with the magneticstimulation pulse• Built in timer and counter with presetoperating period (days and stimulations)• Includes Stimulator Electrode Cable andone pack of Surface Electrodes (12pcs.)Mechanical PropertiesWeight of transducer head 3kgCable length 1.3mDimensions of transducer 174 x 94 x 80 mmheadCoil Winding DataInner diameter35mmOuter diameter75mmWinding height12mmNumber of windings 2x (2 x 5)Magnetic and Electrical PropertiesMax initial dB/dt Max initial dB/dt: 36 kT/s near thecoil surface on the active side,same as Cool-B65 Coil.The magnetic field near the coilsurface on the placebo side isreduced to 20.000 pulseswarm-up at ambienttemperature 20°C:Mean output 100% ofmaximum at 2pps.Number of stimulations, beforewarm-up at ambienttemperature 20°C withprotocol:60 trains @ 50 pulses/train @10pps @ Inter Train Interval:25s @ Output=75%.>10.000 pulsesOrdering Number 9016E050-www.<strong>MagVenture</strong>.com 35

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!