13.07.2015 Views

UIC Code_918 - 3 - saferail.nl

UIC Code_918 - 3 - saferail.nl

UIC Code_918 - 3 - saferail.nl

SHOW MORE
SHOW LESS
  • No tags were found...

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Level 2 - Group 5 - RFR - ReferenceEuropean Railway AgencyERA/TD/2009-07/INT: ANNEX B.4 of TAP TSIFunctionRailway useTo specify a reference.This segment triggers Group 5. It is used to identify a location reference related to the locationdescribed in ALS.The relationship between locations is given by element 1153.This can be:Where 1153 = X01, element 1154 contains a reservation identifier for the ALS location(1153 = X01).In this case the remaining segments of Group 5 (MES and RLS) are not used.Where element 1153 = AWN, elements 1154 contains the timetable identifier of a location(location name code) to which the location described in ALS is related In this case elementRLS/E941/9143 is used to specify further the type of relationship which can be:9143 = 6: There is the possibility to transfer from one location to the other in a giventime (specified in segment MES).9143 = 14: The location is part of a group headed by the ALS location (e.g., stations in atariff zone)Tag Tag Name St Rp Frmt CommentsE506 REFERENCE M 11153 Reference function code qualifier M an..3 See code list B.4.1153. Values:AWN: location name codeX01: reservation identifier1154 Reference identifier C an..35 Mandatory.Reference to a location name code(1153 = AWN) or reference to a reservationidentifier (1153 = X01)1156 Document line identifier C an..6 Not applicable4000 Reference version number C an..35 Not applicable3036 Party name C an..35 Not applicableExampleRFR+AWN:008711300’= Reference to location 008711300, which is „PARIS EST‟Level 3 - Group 5 - MES - MeasurementsFunctionTo specify physical measurements, including dimension tolerances, weights and counts.Railway use This segment may be used to specify the transfer time and the distance to the locationreferenced in Gr5/RFR from the specified location in Gr2/ALS.O<strong>nl</strong>y one occurrence of E175 for transfer time (value MIN for 6411) and o<strong>nl</strong>y one occurrencefor distance (value MTR) is allowed.The reference is unidirectional, i.e. it describes not the distance from the location referencedin RFR segment to the specified location. 1Tag Tag Name St Rp Frmt CommentsE175MEASUREMENT VALUE AND M 9DETAILS6314 Measurement value M n..18 Transfer time or distance.6411 Measure unit code C an..3 Mandatory. Unit of measurement. Seecode list B.4.6411. Values = MIN, MTR.At least the measurement in minutes(MIN) has to be given.6313 Measurement dimension, coded C an..3 Not applicable.6321 Measurement significance code C an..3 Not applicable. “Exact value” assumed.ExampleMES+10:MIN*125:MTR'1 There are a number of locations where the transfer time from the first to the second differs to the transfer timefrom the second to the first.ERA_Technical_Document_TAP_B_4 Version Draft 1.2 Page 57/63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!