13.07.2015 Views

UIC Code_918 - 3 - saferail.nl

UIC Code_918 - 3 - saferail.nl

UIC Code_918 - 3 - saferail.nl

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

European Railway AgencyERA/TD/2009-07/INT: ANNEX B.4 of TAP TSI2380 Date or time or period text C an..35 Mandatory. Frequency first and lasttime. Format = hhmm/hhmm2379 Date or time or period functioncode qualifierC an..3 Not applicableExampleFRQ+30:MIN:0600/2100'= the service operates every 30 minutes from 6 a.m. to 9 p.m.Level 3 - Group 5 - SER - Facility informationFunction To provide additional service information, followed by the period and days of operation.Railway use This segment triggers Group 5, which specifies information about facilities available withthe given transport service o<strong>nl</strong>y for the given period of operation defined in POP. This informationcan be repeated. The segment allows the definition of a sub-period, or specificdays of the weeks for which the facility is available.Each SET segment specifies one and o<strong>nl</strong>y one facility. Repeat the segment as required (up to99 times).Tag Tag Name St Rp Frmt CommentsE965 FACILITIES M 99 One and o<strong>nl</strong>y one occurrence of thiscomposite is used.9039 Facility type description code C an..3 Mandatory. See code list B.4.9039.9038 Facility type description C an..70 Not applicable7133 Product details type code qualifierC an..3 Not applicable7037 Characteristic description code C an..17 Reservation information concerningthe facility. This information can berepeated. See code list B.4.7037.Values = 11, 12, 13, 14, 15, 16, 17,18, 19, 20, 21, 22, 23, 25, 26, 27, 281229 ACTION REQUEST/NOTIFICA- C an..3 Not applicable.TION DESCRIPTION CODE6350 UNITS QUANTITY C n..15 Number of facilities available in theservice.E013DATE AND TIME INFORMA-TIONC 99 One occurrence o<strong>nl</strong>y.Definition of the availability period ofthe facility. If omitted: always availableduring the operation period of thetravel service.The availability period must fit withinthe period of operation of the travelservice defined in segment POP.M an..3 See code list B.4.2005. Value = 273.2005 Date or time or period functioncode qualifier2380 Date or time or period text M an..35 Period of availability. Format = yyyymm-dd/yyyy-mm-dd2379 Date or time or period format C an..3 Not applicablecode4440 Free text value C an..512 May be used to specify the availabilitydays, one day by character ("0" = notavailable, "1" = available), startingfrom the first day specified in the periodof availability (2380).2160 DAYS OF WEEK SET IDENTI-FIERC 1 an..7 String data representation of localday(s) of the week (Monday = 1,Tuesday = 2, etc.). Not used ifE013/4440 is used to specify the operationdaysExampleSER+33::::2:13+273:1997-06-01/1997-09-30'= From 1 June 1997 until 30 September 1997, the service includes 2 video coaches (33)wherein reservation is compulsory (13).ERA_Technical_Document_TAP_B_4 Version Draft 1.2 Page 29/63

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!