13.07.2015 Views

9400 Specifications - Zenitel

9400 Specifications - Zenitel

9400 Specifications - Zenitel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

stations. This test can be performed automatically everyday at a certain time or can be manuallystarted to provide a system evaluation for troubleshooting purposes. The results of the tone testare sent to the logging port for printout.NN.OO.HOTLINE CALL. System shall have the ability from any master station to perform a hotline call.This hotline call is performed by lifting the handset on a master station, which in turn will place acall to a station or feature that is programmable per station in 5 seconds. Default timer of 5seconds is programmable; however this is a system wide timer for all stations.EVENT HANDLING. System shall be capable of providing programmable ASCII data strings tointerface with external data systems such as CCTV, Card Access, etc. These data strings are fullyprogrammable to meet the needs required by the external systems. Event handler data ports areof the fire and forget type, where as the AlphaCom will transmit the data with no handshake.2.5 SYSTEM OPERATIONA. MASTER-TO MASTER CALLSAll masters shall be able to call all other masters individually, point to point, unless blockedthrough programming, by simply touch dialing a 1, 2, 3 or 4 digit number, or by using direct accessbuttons. Once dialed, both stations shall be able to talk by either duplex voice switching or simplexPTT if call is made to or from <strong>9400</strong> module. All standard features listed shall be available to allmasters.B. CALL FROM SECURITY SUBSTATION TO MASTERA call request shall be initiated from a substation by activating an alarm button, or the call-in buttonon the substation. The call request shall indicate to the calling party with a flashing red LED andaudio tone to comply with ADA. It shall be possible to also start an external strobe light (seeoptions). This call request shall be annunciated at the master station as follows:1. The LCD will show you have received a call request from a station.2. A rapidly repeating tone signal sounds. Call request shall be answered by pressingappropriate direct access button preprogrammed to answer all call requests from stations.3. When call is answered the following shall occur:a. A connection tone is heard at both the master and the calling station.b. The flashing red LED illuminates "solid" on the master station.c. The Number and Text of the station that is connected appears in the LCD.d. Clear, two-way communication shall take place.e. Other calls from substations to the master station shall be placed in queue evenduring conversation between master station and the calling station.<strong>Zenitel</strong> USA - 6119 Connecticut Avenue – Kansas City, MO 64120 – 816/231-7200 – Fax: 816/231-7203 – www.zenitelusa.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!