13.07.2015 Views

9400 Specifications - Zenitel

9400 Specifications - Zenitel

9400 Specifications - Zenitel

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

C. AlphaCom E system capacity shall include a modular central exchange cabinet wired andequipped for the necessary stations and speech channels. System shall be expandable by addingplug-in boards and modules to approximately 140,208 stations. The system shall have thecapability to be expanded to multi-mode operation with remote sites, using transparent dialingbetween remote modules. In addition, the central exchange shall also include 50 simplexconference channels, and 100 programmable group call function circuits. The system will beprogrammed to restrict the local master stations from calling other local master stations.D. The <strong>9400</strong> system shall be placed in each wing and connected to the AlphaCom E via 1386 datacombiner board(s) via RS422 data circuits and up to 2-600 ohm 4-wire audio circuits. The <strong>9400</strong>module shall have the capacity to control up to 100 substations or speakers. Up to 50 <strong>9400</strong>modules can be networked together with 4-wire 600 ohm audio and RS422 data. Each <strong>9400</strong>module shall contain the necessary line boards and amplifiers to accommodate each wing’sstation capacity as indicated on the plans. The <strong>9400</strong> modules shall have double E proms forprogram storage and program back up. The module will have two independent speech channelslinked back to the main exchange. Systems with one speech channel will not be accepted.E. <strong>9400</strong> system shall be capable of supporting both 25V type substations by others and 9600 seriessubstations by Stentofon.F. Overhead paging shall be possible to the <strong>9400</strong> from the AlphaCom E exchange.G. The scope of the system shall include all features and functions described herein and theequipment shown on the plans. System shall be capable of adding optional features, equipmentand interfaces listed in the specifications, even if not initially included or shown on the plans. Acomplete operational system shall be provided. The system functions in public areas such aselevators, lobbies and parking areas shall comply with ADA requirements.2.3 SYSTEM CONFIGURATIONA. The AlphaCom E, <strong>9400</strong> Modules, power supplies, batteries, interfaces, page adapters,accessories, and main distribution board, shall be located in an appropriate secure dataprocessing room(s), separate from the telephone equipment room (as shown on the plans).B. System shall consist of duplex master stations with direct access buttons, with or withouthandsets, and with or without LCD displays, as indicated on the plans. Each master shall becapable of calling all other stations in the system unless specifically blocked or restricted throughprogramming.C. Security control room masters, and all other master stations shall be desk, flush, surface, wallmounted, or rack mounted as shown on the plans.D. Substations shall be flush or surface mounted, tamper and weather resistant where needed andlocated as required for direct access calling to control room masters, as shown on the plans.Specify if substations are to be connected to an AlphaCom E or to <strong>9400</strong> module.E. System shall include a "supervisor's" display type master control station at or near the centralexchange to function as system maintenance and fault indication station.F. All features and functions shall be programmed on site with a standard PC via Ethernet portconnection. Any system requiring a PC to run the system shall not be accepted.<strong>Zenitel</strong> USA - 6119 Connecticut Avenue – Kansas City, MO 64120 – 816/231-7200 – Fax: 816/231-7203 – www.zenitelusa.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!