13.07.2015 Views

9400 Specifications - Zenitel

9400 Specifications - Zenitel

9400 Specifications - Zenitel

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

M. 9629 – SUBSTATION BOARD. The 9629 board is used for connection of a 45 ohm speaker andcall button to create a 9600 series substation. It’s also used for the 9620, 9621, 9626 and 9628units. This is a PC board the customer is responsible for mounting in suitable enclosure. The 9629board requires 1 pair of wire for installation.Note to specifier: Call buttons are normally open momentary close type. On/off buttons can beused on units that require call buttons however the button must be reset before the call is ended orupon cancellation of call the station will place a call.N. SUBSTATIONS – 25V TYPE. These substations are commercially available and are used forsecurity, correctional and school applications. Stations come in a variety of sizes with 25V speakerand with or without call buttons. If substation is not equipped with a call button, a single pair of wireis needed for installation. If substation is equipped with a call button, 2 pair of wire is needed forinstallation. If 25V substations are used then 25V amplifiers must be provided for outgoing audio.Note 1: <strong>Zenitel</strong> USA does not provide 25V substations.Note 2: Existing substations using a 45-ohm speaker with no termination and a separate callbutton can be connected to this module. In this case you need two pair of wire.O. 9457 – CONNECTION CABLE FOR LINE BOARDS. The 9457 connection cable kit is a 50 pinfemale Amphenol cable assembly. The kit connects to connectors on the back plane of the 9401for each 9450 line card slot. The 9457 kit is then mounted via standoffs on the back of the 9401rack for a neat installation of station cables. One 9457 connection cable kit is required per 9450line board used.P. 96580 – CABLE AND CONNECTOR. The 96580 cable and connector is equipped with a 50 pinmale Amphenol for connection to a 9457 and a cable length of 20 feet with bare wire at the otherend for punching down wire on a 96570 MDF block. One 96580 cable and connector is requiredper 9450-line board used.Q. 96570 – BASIC MDF. The 96570 basic MDF is a standard “66” telephone block used to punchdown wiring from the 96580 cable and wiring to/from the substations in the field. One 96570 isrequired per 9450 line board.R. SDR-114 – SOUND THRESHOLD BOARD. The SDR-114 board is used in conjunction with the9600 substations to place a call to the <strong>9400</strong> system when an audio disturbance above a certainsound level and duration occurs. The SDR-114 is housed in a SDR-D series card cage.S. SDR-D SERIES CARD CAGE RACK. The SDR-D series card cage rack is used for SDR-114boards. Each SDR-D series rack is capable of housing up to 25 boards in multiples of 5 boards ata time. 5, 10, 15, 20 and 25 card cage sizes are available.2.6.2 OPTIONS FOR ALPHACOM E (Available with additional equipment)A. MICROPHONE AMPLIFIER & RELAY (MADER). Shall provide amplified calling and two-waycommunication through separate loudspeaker, and preamplified audio input through either electretor dynamic microphone. Shall include relay control and adjustments for in/out volume. Shall beSTENTOFON #99601.<strong>Zenitel</strong> USA - 6119 Connecticut Avenue – Kansas City, MO 64120 – 816/231-7200 – Fax: 816/231-7203 – www.zenitelusa.com

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!