for better solutions…<strong>Shear</strong> <strong>dowel</strong><strong>Shear</strong> force transmission in expansion jointsReliable expansionjoint <strong>dowel</strong>ling inconcrete structuralelementsReinforcement for a safe connection


<strong>Shear</strong> <strong>dowel</strong> HEDGeneralSingle shear <strong>dowel</strong> HED – Expansion joint <strong>dowel</strong>ling for concrete structural elementsThe productDue to the use of these HED Typeshear <strong>dowel</strong>s, <strong>dowel</strong>ling applicationson expansion joints can be solvedsimply and reliably even where thereare varying shear forces.It guarantees a displacement of thestructural element in the longitudinalaxis of the rod up to a joint width of50 mm.All types are available with a specialfire protection sleeve for classificationaccording to F90.FeaturesPrevents component displacementin the area of the jointSimple, precise-fit assembly usingshear <strong>dowel</strong> sleeves on the shuttering.A rip-proof film protects thesleeve from ingress of concreteThere is no requirement to drillthrough the shuttering or supplementarydrilling of the concrete.Application areaSingle Type HED shear <strong>dowel</strong>s areused wherever shear forces are to betransferred through structural joints,e.g. expansion joints between concreteslabs, in floors and walls, forjoints between supports and walls orbetween balconies and floors.50www.h-bau.com


<strong>Shear</strong> <strong>dowel</strong> HEDTypes and dimensionsfor better solutions…Types<strong>Shear</strong> <strong>dowel</strong> HED-S + GS sleevesMotion in the longitudinal directionTransfer of the shear forcesStainless steel sliding sleeve<strong>Shear</strong> <strong>dowel</strong> HED-S + GSQ sleevesMotion in the longitudinal andtransverse directionTransfer of the shear forcesStainless steel sliding sleeve<strong>Shear</strong> <strong>dowel</strong> HED-S + GK sleevesMotion in the longitudinal directionTransfer of the shear forcesPlastic sliding sleeve<strong>Shear</strong> <strong>dowel</strong> HED-PMotion in the longitudinal directionTransfer of the shear forcesWith plasticized spring elementDimensionsType[mm]HED-SHED-P<strong>dowel</strong> Ø[mm]<strong>dowel</strong> element Sleeves GS, GK Sleeves GSQ<strong>dowel</strong> lengthl D [mm]sleeve lengthl H [mm]Nail plateB/H [mm]sleeve lengthl H [mm]Nail plateB/H [mm]max transversedisplacementy [mm]20 20 300 160 70/70 180 80/80 ± 1122 22 300 160 70/70 180 80/80 ± 1025 25 300 160 70/70 180 80/80 ± 1430 30 350 185 80/80 205 100/80 ± 21SHEAR DOWEL51Reinforcement for a safe connection


<strong>Shear</strong> <strong>dowel</strong> HEDFire protectionFire protection sleevesIf there are technical fire protectionrequirements on the construction elementsaccording to DIN 4102 Part 2,the shear <strong>dowel</strong>s must be installedwith fire protection sleeves.In order to meet the classification F90the unprotected <strong>dowel</strong> must be fittedwith a fire protection sleeve in thejoint.In the event of a fire, the fire protectionsleeve foams and completely fillsthe joint.The sleeves are supplied in the followingstrengths:20 for joint width 20-30 mm40 for joint width 40 - 50 mmThe fire protection sleeves can becombined for larger joint widths.Dimensions of the fire protection sleevesFire protection sleeve for HED-S + GS/GK & HED-P110 x 110 mm (b x h)hole diameter Ø 20 mm - Ø 30 mmstrength 20 mm und 40 mmFire protection sleeve for HED-S + GSQ160 x 110 mm (b x h)hole diameter Ø 20 mm - Ø 30 mmstrength 20 mm und 40 mm54www.h-bau.com


<strong>Shear</strong> <strong>dowel</strong> HEDInstallation instructionsfor better solutions…Installation instructions Schubdorn HED-SshutteringNail plateon-site reinforcementsleeveshutteringsleeveNail the sleeve on to the shutteringDo NOT remove protective stickerArrange the reinforcement in accordance with thereinforcement planConcrete in the first sectionsleeveprotective stickerjoint materialStrip the shutteringApply the joint materialRemove protective stickerjoint materialfire protection sleevefire protection sleevejoint material<strong>dowel</strong>Cut an aperture in the joint materialAttach the fire protection sleevePush the <strong>dowel</strong> into the sleevesleeve on-site reinforcement <strong>dowel</strong>Arrange the reinforcement in accordance with thereinforcement planConcrete in the second sectionSHEAR DOWEL55Reinforcement for a safe connection