13.07.2015 Views

Accessibility Requirements in the National Building Code of Canada ...

Accessibility Requirements in the National Building Code of Canada ...

Accessibility Requirements in the National Building Code of Canada ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ACCESSIBILITY REQUIREMENTS IN THE NATIONAL BUILDINGCODE OF CANADA 1985by A.T. HansenTechnical Information GroupDivision <strong>of</strong> Build<strong>in</strong>g ResearchBPN 53June 1985ISSN 0701-5216@<strong>National</strong> Research Council <strong>Canada</strong> 1985


ABSTRACTNew requirements to facilitate <strong>the</strong> use <strong>of</strong> build<strong>in</strong>gs by persons with physical disabilitiesare <strong>in</strong>cluded <strong>in</strong> <strong>the</strong> 1985 edition <strong>of</strong> <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong>. The significance <strong>of</strong> <strong>the</strong>sechanges is discussed. Excerpts from <strong>the</strong> new requirements are <strong>in</strong>cluded, toge<strong>the</strong>r wi<strong>the</strong>xplanatory diagrams.RESUMEL’kdition 1985 du <strong>Code</strong> national du bltiment renferme de nouvelles exigences visant iifaciliter l’accks aux bltiments pour les personnes handicap6es physiquement. Cette communicationexam<strong>in</strong>e la portke de ces modifications et contient des extraits des nouvellesexigences a<strong>in</strong>si que des tableaux explicatifs.1


INTRODUCTIONModel requirements for accessibility <strong>in</strong> build<strong>in</strong>gs were <strong>in</strong>troduced <strong>in</strong> <strong>Canada</strong> with <strong>the</strong>publication <strong>in</strong> 1965 <strong>of</strong> a Supplement to <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> entitled “Build<strong>in</strong>gStandards for <strong>the</strong> Handicapped” [I]. This was published under <strong>the</strong> auspices <strong>of</strong> <strong>the</strong> AssociateCommittee on <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong>. These accessibility requirements were <strong>in</strong>tendedto facilitate <strong>the</strong> use <strong>of</strong> build<strong>in</strong>gs by persons with physical disabilities, particularly thoseconf<strong>in</strong>ed to wheelchairs. In 1975, accessibility requirements were <strong>in</strong>cluded for <strong>the</strong> firsttime <strong>in</strong> <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> (NBC) itself.[2] These required that ‘public build<strong>in</strong>gs’have an accessible entrance and provide wheelchair access to all public spaces, <strong>in</strong>clud<strong>in</strong>gelevators, on <strong>the</strong> entrance floor. Where public washrooms were provided, at least onewas required to be accessible to persons <strong>in</strong> wheelchairs. Public build<strong>in</strong>gs were def<strong>in</strong>ed asthose to which <strong>the</strong> public is admitted, but did not <strong>in</strong>clude apartment build<strong>in</strong>gs, <strong>in</strong>dustrialbuild<strong>in</strong>gs, or <strong>of</strong>fice type occupancies, under a s<strong>in</strong>gle tenancy. Although <strong>the</strong>se requirementswere modified <strong>in</strong> subsequent editions to <strong>in</strong>clude additional occupancies, <strong>the</strong>y rema<strong>in</strong>edbasically unchanged up to <strong>the</strong> 1985 edition.The 1985 edition [3] extended significantly <strong>the</strong> scope <strong>of</strong> <strong>the</strong>se requirements. No longeris reference made to <strong>the</strong> “Build<strong>in</strong>g Standards for <strong>the</strong> Handicapped” for required designdetails. All relevant requirements now appear <strong>in</strong> <strong>the</strong> NBC and <strong>the</strong> ‘Standards’ has beendiscont<strong>in</strong>ued. These requirements, like <strong>the</strong> rest <strong>of</strong> <strong>the</strong> code, are model requirements andhave no legal status until adopted by an authority with <strong>the</strong> legal power to do so.A complete new Section 3.7 has been added to Part 3 <strong>of</strong> <strong>the</strong> <strong>Code</strong>, which deals exclusivelywith accessibility. The requirements apply to all build<strong>in</strong>gs except detached, semi-detached,duplex, triplex, row, town and board<strong>in</strong>g houses, high hazard <strong>in</strong>dustrial build<strong>in</strong>gs, and build<strong>in</strong>gsthat are normally unoccupied (e.g. pump houses, substations, automated telephoneexhanges). Part 9 <strong>of</strong> <strong>the</strong> <strong>Code</strong>, which applies to houses and small build<strong>in</strong>gs, fur<strong>the</strong>r exemptsapartment build<strong>in</strong>gs that do not have elevators. S<strong>in</strong>ce Part 9 references Section 3.7for accessibility requirements, <strong>the</strong>se apply to both parts.At least one pr<strong>in</strong>cipal entrance <strong>in</strong> every build<strong>in</strong>g with<strong>in</strong> <strong>the</strong> scope <strong>of</strong> <strong>the</strong> new Section isrequired to have a ‘barrier-free access’. This is a newly def<strong>in</strong>ed term that designates a path<strong>of</strong> travel negotiable by a wheelchair. Figure 1 shows an accessible entrance constructed<strong>in</strong> conformance with <strong>the</strong> new requirements. Where a barrier-free access is between floorlevels, it <strong>in</strong>cludes ramps and elevators.A barrier-free access is required from <strong>the</strong> accessible entrance to various specified areas andfacilities on <strong>the</strong> entrance floor, and on every floor served by an elevator if an elevator isprovided. The designated areas and facilities to which barrier-free access must be providedare those that serve <strong>the</strong> public or are designed for use by visitors. These <strong>in</strong>clude assemblyareas with fixed seats, display areas, merchandis<strong>in</strong>g departments, general work areas suchas <strong>of</strong>fice areas or areas <strong>of</strong> general use such as laundries, recreational areas, cafeterias,lounge rooms, lunch rooms and <strong>in</strong>firmaries. Access is also required to each classroom, suite,patient’s room, ticket counter, refreshment stand, dr<strong>in</strong>k<strong>in</strong>g founta<strong>in</strong>, check-out counter and2


920 mm HIGH GUARDFIGURE.l Accessible entrance show<strong>in</strong>g m<strong>in</strong>imum dimensions3


. ‘ at least one elevator where elevators are provided. Where park<strong>in</strong>g is provided, barrier-freeaccess must also be provided from <strong>the</strong> park<strong>in</strong>g area to an accessible entrance.In assembly areas with fixed seats, a specified number <strong>of</strong> spaces must be provided toaccommodate wheelchairs, depend<strong>in</strong>g on <strong>the</strong> total seat<strong>in</strong>g. This varies from a m<strong>in</strong>imum<strong>of</strong> 2 spaces for up to 200 seats to 7 spaces for up to 1 000 seats. Over this numberonly one additional space is required for each additional 1 000 seats up to a maximum<strong>of</strong> 20 spaces. All washrooms are required to be designed for accessibility unless <strong>the</strong>y arelocated <strong>in</strong> residential suites (e.g., houses, apartments, hotel rooms), or are on floors towhich barrier-free access is not provided (e.g., floors not served by elevators or ramps).O<strong>the</strong>r washrooms can also be exempted if <strong>the</strong>re are accessible washrooms available thatare equally convenient to <strong>the</strong> occupant.S<strong>in</strong>ce wheelchair users are not able to reach as high as ambulatory occupants, all controlsfor <strong>the</strong> operation <strong>of</strong> build<strong>in</strong>g services or safety devices <strong>in</strong>tended to be used by <strong>the</strong> occupantsare to be mounted with<strong>in</strong> 1.4 m <strong>of</strong> <strong>the</strong> floor when <strong>the</strong>y are located <strong>in</strong> a barrier-free accessarea. This <strong>in</strong>cludes electrical switches, <strong>the</strong>rmostats and <strong>in</strong>tercom switches.Specific requirements are <strong>in</strong>cluded for facilities designed for use by <strong>the</strong> disabled. These<strong>in</strong>clude doorways, door closers, walkways, vestibules, ramps, elevators, waterclosets, waterclosetstalls, shower stalls and washrooms. Signs for designated facilities for <strong>the</strong> disabledare also specified. Although many <strong>of</strong> <strong>the</strong> specified requirements for <strong>the</strong>se facilities are basedon those conta<strong>in</strong>ed <strong>in</strong> <strong>the</strong> former “Build<strong>in</strong>g Standards for <strong>the</strong> Handicapped”, a number <strong>of</strong>significant changes were made when <strong>the</strong>se were transferred to <strong>the</strong> NBC.Exterior walkways, for example, are now required to be 1.1 m wide (up from 920 mm).Door closers <strong>in</strong> a barrier-free access area must be designed to allow doors to open undera force <strong>of</strong> 38 N (8 lb) <strong>in</strong> <strong>the</strong> case <strong>of</strong> exterior doors and 22 N (5 lb) <strong>in</strong> <strong>the</strong> case <strong>of</strong> <strong>in</strong>teriordoors. This is due to <strong>the</strong> difficulty that many wheelchair users and those with impairedwalk<strong>in</strong>g capability have <strong>in</strong> us<strong>in</strong>g self-clos<strong>in</strong>g doors. This compares to 90 N (20 lb) normallyspecified as <strong>the</strong> maximum force for exit doors. Closers must have a clos<strong>in</strong>g period <strong>of</strong> atleast three seconds to facilitate wheelchair passage. Every vestibule <strong>in</strong> a barrier-free accessarea is required to be designed so that a wheelchair can pass through it without excessive<strong>in</strong>terference from doors. Doors <strong>in</strong>to <strong>the</strong> vestibule must be at least 1.2 m apart plus <strong>the</strong>width <strong>of</strong> any door sw<strong>in</strong>g<strong>in</strong>g <strong>in</strong>to it. A space at least 600 mm beside <strong>the</strong> latch side <strong>of</strong> <strong>the</strong>door must be provided where a door sw<strong>in</strong>gs <strong>in</strong>to <strong>the</strong> vestibule and at least 300 mm whereit sw<strong>in</strong>gs out <strong>of</strong> <strong>the</strong> vestibule (Figure 2).Although ramp slopes are still limited to a maximum <strong>of</strong> 1 <strong>in</strong> 12 <strong>in</strong> most <strong>in</strong>stances, a 1 <strong>in</strong> 10slope is now permitted for ramps up to 3 m long (Figure 1).Water closet stalls must now be at least 1.5 by 1.5 m (up from 1.37 by 1.52 m) and beequipped with an outward sw<strong>in</strong>g<strong>in</strong>g door that provides a 760 mm clear open<strong>in</strong>g (Figure 3).Water closets must now have a m<strong>in</strong>imum seat height <strong>of</strong> 400 mm above <strong>the</strong> floor as well asa maximum height <strong>of</strong> 460 mm. Grab bars for water closets can now be from 30 to 40 mm4


760 mm MIN.FIGURE 2. Vestibule dimensions760 mmCLEARFIGURE 3. M<strong>in</strong>imum dimensions for accessible washrooms5


I.diameter (down from 45 to 50 mm) and must meet certa<strong>in</strong> strength requirements (1.3 kNor 290 lb applied vertically or horizontally, see Figure 4). When shower stalls are providedfor <strong>the</strong> disabled, <strong>the</strong>y must be at least 920 by 920 mm, equipped with a h<strong>in</strong>ged seat, grabbars, and hand-held shower, pressure-balanced s<strong>in</strong>gle lever controls and a slip-resistantfloor.In addition to <strong>the</strong> accessibility requirements <strong>in</strong> Section 3.7, fire safety requirements havebeen <strong>in</strong>cluded for accessible floor areas located above <strong>the</strong> first storey if <strong>the</strong> build<strong>in</strong>g isnot spr<strong>in</strong>klered (or served by exit ramps). Article 3.3.1.5. (which is also referenced <strong>in</strong>9.9.2.7.) allows several alternative measures to accommodate disabled occupants <strong>in</strong> fireemergencies. The elevator may be specially designed to evacuate <strong>the</strong> disabled, <strong>the</strong> build<strong>in</strong>gmay be vertically divided <strong>in</strong>to two separate fire zones, or, <strong>in</strong> <strong>the</strong> case <strong>of</strong> residential build<strong>in</strong>gs,balconies can be used to provide temporary refuge. When <strong>the</strong> elevator evacuation option isused, <strong>the</strong> elevators are required to be protected on each floor by a vestibule provid<strong>in</strong>g threequarters<strong>of</strong> an hour fire resistance or a corridor provid<strong>in</strong>g one hour fire resistance. O<strong>the</strong>rmeasures required for fire fighters’ elevators <strong>in</strong> high build<strong>in</strong>gs also have to be provided for<strong>the</strong>se elevators to ensure service under fire conditions. In build<strong>in</strong>gs over three storeys high,measures to keep <strong>the</strong> elevator smoke-free are required as well. Where balconies are usedas an option, <strong>the</strong> balconies are subject to <strong>the</strong> same requirements currently applied to those<strong>in</strong> high build<strong>in</strong>gs that are <strong>in</strong>tended for temporary refuge from fire.Additional requirements to accommodate <strong>the</strong> bl<strong>in</strong>d or <strong>the</strong> sight-impaired have also beenadded. These are not restricted to barrier-free access routes but apply to all areas andto all build<strong>in</strong>gs. These <strong>in</strong>clude requirements for tactile numbers on elevator door jambs(3.5.5.1.(4)) and exit doors (3.4.7.12.(18)), <strong>the</strong> elim<strong>in</strong>ation <strong>of</strong> obstructions that are notdetectable by <strong>the</strong> use <strong>of</strong> a cane <strong>in</strong> exits and corridors (3.3.1.7.(3) and (4), 9.9.5.3. and9.9.5.4.), cont<strong>in</strong>uity <strong>of</strong> at least one handrail around stair land<strong>in</strong>gs (3.4.7.5.(5) and 9.8.7.2.)and <strong>the</strong> safe term<strong>in</strong>ation <strong>of</strong> <strong>the</strong> ends <strong>of</strong> handrails to prevent <strong>the</strong>m from be<strong>in</strong>g a hazard(3.4.7.5.(6) and 9.8.7.3.). In order to assist ambulatory people with walk<strong>in</strong>g difficulties,handrails for stairs and ramps are required to extend horizontally at least 300 mm beyond<strong>the</strong> tops and bottoms <strong>of</strong> stairs (3.4.7.5.(7) and 9.8.7.4.) (Figure 5). This extension ispermitted to be at an angle to <strong>the</strong> direction <strong>of</strong> <strong>the</strong> stair to avoid project<strong>in</strong>g <strong>the</strong> handrail<strong>in</strong>to a path <strong>of</strong> travel.Extracts have been provided from <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> <strong>of</strong> <strong>Canada</strong> 1985. These<strong>in</strong>clude <strong>the</strong> new Section 3.7, as well as <strong>the</strong> requirements for <strong>the</strong> visually-impaired. Explanatorymaterial <strong>in</strong> <strong>the</strong> appendix to <strong>the</strong> NBC is <strong>in</strong>cluded as well, immediately after <strong>the</strong>applicable requirements.Some prov<strong>in</strong>ces have developed requirements for accessibility <strong>in</strong>dependently from those <strong>in</strong><strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong>. Designers, <strong>the</strong>refore, should check with local authorities todeterm<strong>in</strong>e those requirements applicable to <strong>the</strong>ir design.6


BACK GRAB BAR REQUIREDWHEN TOILETHASNOFLUSH TANK FORSUPPORTFIGURE 4. Grab bars for toiletsFIGURE 5. Handrail term<strong>in</strong>ation7


EXTRACTS FROM THE NATIONAL BUILDING CODE OF CANADA 1985Def<strong>in</strong>itionBarrier-free access means a path <strong>of</strong> travel designed for use by persons with physical orsensory disabilities, <strong>in</strong>clud<strong>in</strong>g those us<strong>in</strong>g wheelchairs, and <strong>in</strong>corporat<strong>in</strong>g ramps, elevatorsor o<strong>the</strong>r lift<strong>in</strong>g devices where <strong>the</strong>re is a difference <strong>in</strong> elevation between floor levels along<strong>the</strong> path <strong>of</strong> travel.EXTRACTS FROM PART 3Fire Safety Provisions3.3.1.5.(1) Where a barrier-free access is provided above <strong>the</strong> first storey <strong>in</strong> a build<strong>in</strong>g thatis not spr<strong>in</strong>klered, every floor area hav<strong>in</strong>g such access shallExplanat ionbe served by an elevator conform<strong>in</strong>g to Sentences 3.2.6.4.(4) to (7), protected aga<strong>in</strong>stfire <strong>in</strong> conformance with Clauses 3.2.6.4.(3) (b) or (c) and, <strong>in</strong> build<strong>in</strong>gs over 3storeys <strong>in</strong> build<strong>in</strong>g height, protected aga<strong>in</strong>st smoke movement <strong>in</strong> conformance withSentence 3.2.6.2.(4),be divided <strong>in</strong> at least 2 zones conform<strong>in</strong>g to Sentences 3.3.3.5.(8) and (9) so thatdisabled persons can be acommodated <strong>in</strong> each zone,<strong>in</strong> <strong>the</strong> case <strong>of</strong> residential occupancies, be provided with balconies conform<strong>in</strong>g toSentence 3.2.6.2. (8), except on <strong>the</strong> storey conta<strong>in</strong><strong>in</strong>g <strong>the</strong> access entrance described<strong>in</strong> Article 3.7.1.1., orhave an exterior exit at ground level or a ramp lead<strong>in</strong>g to ground level.These measures are <strong>in</strong>tended to provide temporary refuge for disabled persons. It is acknowledged,however, that <strong>the</strong> measures cannot provide absolute safety for all occupants<strong>in</strong> <strong>the</strong> fire area. It may, <strong>the</strong>refore, be necessary to develop special arrangements <strong>in</strong> <strong>the</strong>fire safety plan to evacuate disabled persons from <strong>the</strong>se areas. Details for such a plan areconta<strong>in</strong>ed <strong>in</strong> <strong>the</strong> <strong>National</strong> Fire <strong>Code</strong> <strong>of</strong> <strong>Canada</strong> 1985.The protected elevator <strong>in</strong> Clause (l)(a) is <strong>in</strong>tended to be used by fire fighters as a meansfor evacuat<strong>in</strong>g disabled persons. It is not <strong>in</strong>tended that this elevator be used by disabledpersons as a means <strong>of</strong> egress without <strong>the</strong> assistance <strong>of</strong> fire fighters.I8


Explanat ionHandrails should be easy to grasp. A circular section with a diameter <strong>of</strong> not more than40 mm is <strong>the</strong> preferred shape. Wide or deep handrails are undesirable unless a properhand-size grasp<strong>in</strong>g area is provided.MINIMUM MAXIMUMQEASY TO GRASPDIFFICULT TO GRASPBR 6506-33.4.7.5.(4) Handrails on stairs and ramps shall be not less than 800 mm and not morethan 920 mm <strong>in</strong> height, measured vertically from a l<strong>in</strong>e drawn through <strong>the</strong> outside edges<strong>of</strong> <strong>the</strong> stair nos<strong>in</strong>g or from <strong>the</strong> surface <strong>of</strong> <strong>the</strong> ramp, except that handrails not meet<strong>in</strong>g<strong>the</strong>se requirements are permitted provided <strong>the</strong>y are <strong>in</strong>stalled <strong>in</strong> addition to <strong>the</strong> requiredhandrail.3.4.7.5.(5) At least 1 handrail shall be cont<strong>in</strong>uous throughout <strong>the</strong> length <strong>of</strong> <strong>the</strong> stairway,<strong>in</strong>clud<strong>in</strong>g land<strong>in</strong>gs, except where <strong>in</strong>terrupted by doorways or newels at changes <strong>in</strong> direction.ExplanationLBl<strong>in</strong>d or visually-impaired persons rely on handrails to guide <strong>the</strong>m on stairways. A cont<strong>in</strong>uoushandrail will assist <strong>the</strong>m <strong>in</strong> negotiat<strong>in</strong>g stairs at changes <strong>in</strong> direction.3.4.7.5.(6) Handrails shall be term<strong>in</strong>ated <strong>in</strong> a manner which will not obstruct pedestriantravel or create a hazard.Handrails should return to <strong>the</strong> wall, floor or post, so as not to constitute a hazard to bl<strong>in</strong>dor visually-impaired persons.3.4.7.5.(7) Handrails at <strong>the</strong> sides <strong>of</strong> stairs and ramps shall extend horizontally at least300 mm beyond <strong>the</strong> top and bottom <strong>of</strong> <strong>the</strong> stairways and ramps.10


Explanat ionThe extended handrail is useful to persons with physical limitations to steady <strong>the</strong>mselvesbefore us<strong>in</strong>g <strong>the</strong> stairs.3.4.7.5.(8) A clearance <strong>of</strong> at least 40 mm shall be provided between every handrail andany wall to which it is fastened.3.4.7.5.(9) W<strong>in</strong>dows <strong>in</strong> exit stairways that extend to less than 1 070 mm above <strong>the</strong> land<strong>in</strong>gshall be protected by a barrier or rail<strong>in</strong>g located approximately 1 070 mm above suchland<strong>in</strong>g.Guards3.4.7.6.(1) Every exit such as a ramp, stairway or passageway shall have a wall or awell-secured guard on each side.3.4.7.6.(2) Except as provided <strong>in</strong> Sentence (3), <strong>the</strong> height <strong>of</strong> guards on exit stairs shallbe not less than 920 mm measured vertically to <strong>the</strong> top <strong>of</strong> <strong>the</strong> guard from a l<strong>in</strong>e drawnthrough <strong>the</strong> outside edges <strong>of</strong> <strong>the</strong> stair nos<strong>in</strong>gs and 1 070 mm around land<strong>in</strong>gs.3.4.7.6.(3) The height <strong>of</strong> guards <strong>of</strong> exterior stairs and land<strong>in</strong>gs more than 10 m aboveadjacent ground level shall not be less than 1 500 mm measured vertically to <strong>the</strong> top <strong>of</strong><strong>the</strong> guard from a l<strong>in</strong>e drawn through <strong>the</strong> outside edges <strong>of</strong> <strong>the</strong> stair nos<strong>in</strong>gs.3.4.7.6.(4) The size <strong>of</strong> any open<strong>in</strong>g through guards for exits shall be such as to prevent<strong>the</strong> passage <strong>of</strong> a spherical object hav<strong>in</strong>g a diameter <strong>of</strong> 100 mm <strong>in</strong> build<strong>in</strong>gs <strong>of</strong> residentialoccupancy and 200 mm <strong>in</strong> build<strong>in</strong>gs <strong>of</strong> o<strong>the</strong>r occupancy, except where <strong>the</strong> location andsize <strong>of</strong> <strong>the</strong> open<strong>in</strong>gs that exceed this limit do not present a hazardous condition.Tactile Signs for Exits3.4.7.12.( 18) Arabic numerals <strong>in</strong>dicat<strong>in</strong>g <strong>the</strong> assigned floor number shall(a) be mounted permanently on <strong>the</strong> stair side <strong>of</strong> <strong>the</strong> wall at <strong>the</strong> latch side <strong>of</strong> doors toexit stair shafts,(b) be at least 60 mm high, raised approximately 0.7 mm above <strong>the</strong> surface,(c) be located 1 500 mm from <strong>the</strong> f<strong>in</strong>ished floor and not more than 300 mm from <strong>the</strong>door, and(d)be contrast<strong>in</strong>g <strong>in</strong> colour with <strong>the</strong> surface on which <strong>the</strong>y are applied.11


ExplanationThe identification <strong>of</strong> floor and o<strong>the</strong>r signs <strong>in</strong>tended to facilitate orientation for visuallyimpairedpersons should <strong>of</strong>fer maximum colour contrast to be effective. For this reason,it is recommended that white on black or black on white be used, as this comb<strong>in</strong>ationproduces <strong>the</strong> best legibility. It is also recommended that <strong>the</strong> sign surfaces be processed soas to prevent glare.Tactile Signs for Elevators3.5.5.1.(4) Arabic numerals <strong>in</strong>dicat<strong>in</strong>g <strong>the</strong> assigned floor number shall be mounted permanentlyon both jambs <strong>of</strong> passenger elevator hoistway entrances <strong>in</strong> conformance withAppendix E <strong>of</strong> CSA B44, “Safety <strong>Code</strong> for Elevators, Dumbwaiters, Escalators and Mov<strong>in</strong>gWalks.”SECTION 3.7BARRIER-FREE DESIGNSubsection 3.7.1. General3.7.1.1. The requirements <strong>of</strong> this Section apply to all build<strong>in</strong>gs except(a) houses, <strong>in</strong>clud<strong>in</strong>g semi-detached, duplexes, triplexes, town houses, row houses andboard<strong>in</strong>g houses,(b) build<strong>in</strong>gs <strong>of</strong> Group F, Division 1 major occupancy, and(c) build<strong>in</strong>gs which are not <strong>in</strong>tended to be occupied on a daily or full time basis, <strong>in</strong>clud<strong>in</strong>gautomatic telephone exchanges, pumphouses and substations.3.7.1.2. Every build<strong>in</strong>g <strong>in</strong> Article 3.7.1.1. shall have at least 1 entrance <strong>in</strong>tended forgeneral use by <strong>the</strong> public or <strong>the</strong> occupants designed <strong>in</strong> conformance with Article 3.7.3.3.,open<strong>in</strong>g to <strong>the</strong> outdoors at sidewalk level or to a ramp comform<strong>in</strong>g to Article 3.7.3.4.lead<strong>in</strong>g to a sidewalk.ExplanationAn accessible route should exist from <strong>the</strong> sidewalk or roadway and park<strong>in</strong>g area to anaccessible build<strong>in</strong>g entrance. This route should be located so that disabled persons do nothave to pass beh<strong>in</strong>d parked cars.3.7.1.3.( 1) Except as permitted <strong>in</strong> Subsection 3.7.3., every barrier-free access shall providean unobstructed width <strong>of</strong> at least 920 mm for <strong>the</strong> passage <strong>of</strong> wheelchairs.3.7.1.3.(2) Floor surfaces along a barrier-free access shall have no open<strong>in</strong>g that will permit<strong>the</strong> passage <strong>of</strong> a sphere larger than 13 mm diam.12


3.7.1.3.(3) Except as provided <strong>in</strong> Article 3.7.3.5., controls for <strong>the</strong> operation <strong>of</strong> build<strong>in</strong>gservices or safety devices, located <strong>in</strong> a barrier-free access and <strong>in</strong>tended to be operated by<strong>the</strong> occupant, <strong>in</strong>clud<strong>in</strong>g electrical switches, <strong>the</strong>rmostats and <strong>in</strong>tercom switches, shall beaccessible to a person <strong>in</strong> a wheelchair and shall be mounted at not more than 1.4 m above<strong>the</strong> floor.Subsection 3.7.2. Occupancy <strong>Requirements</strong>3.7.2.1.(1) A barrier-free access shall be provided on <strong>the</strong> entrance storey and on eachstorey served by a passenger type elevator or o<strong>the</strong>r platform equipped passenger elevat<strong>in</strong>gdevice from <strong>the</strong> entrance described <strong>in</strong> Article 3.7.1.2.Explanat ion<strong>in</strong>to each suite,<strong>in</strong>to rooms or areas that serve <strong>the</strong> public or are designated for use by visitors, <strong>in</strong>clud<strong>in</strong>gareas <strong>in</strong> assembly occupancies with fixed seats, display areas and merchandis<strong>in</strong>gdepartments,<strong>in</strong>to rooms or areas for student use <strong>in</strong> assembly occupancies,<strong>in</strong>to general work areas, <strong>in</strong>clud<strong>in</strong>g <strong>of</strong>fice areas,<strong>in</strong>to general use or general service areas, <strong>in</strong>clud<strong>in</strong>g shared laundry areas <strong>in</strong> residentialoccupancies, recreational areas, cafeteria, lounge rooms, lunch rooms and<strong>in</strong>firmaries,<strong>in</strong>to patients’ rooms,<strong>in</strong>to at least 1 passenger type elevator or elevat<strong>in</strong>g device conform<strong>in</strong>g to Article3.7.3.5.,<strong>in</strong>to washrooms described <strong>in</strong> Article 3.7.2.3.,to any facility required by this Section to be designed to accommodate disabledpersons,onto every balcony provided <strong>in</strong> conformance with Sentence 3.3.1.5.(1), and,to ticket counters, refreshment stands, dr<strong>in</strong>k<strong>in</strong>g founta<strong>in</strong>s and checkout counters.Where barrier-free access is required <strong>in</strong>to suites or rooms <strong>in</strong> Subsection 3.7.2., it is not<strong>in</strong>tended that such access be provided throughout each room or suite. In Clause (k), itis not <strong>in</strong>tended that all facilities be accessible. It is <strong>in</strong>tended that sufficient facilities beaccessible to permit a reasonable use <strong>of</strong> <strong>the</strong> build<strong>in</strong>g.13


ExplanationIt is not <strong>in</strong>tended that a separate accessible entrance must be provided from <strong>the</strong> exteriorpark<strong>in</strong>g area. The designer may choose to designate <strong>the</strong> entrance lead<strong>in</strong>g to <strong>the</strong> exteriorpark<strong>in</strong>g area as <strong>the</strong> required entrance or provide a properly identified and unobstructedpath <strong>of</strong> travel from <strong>the</strong> park<strong>in</strong>g area to <strong>the</strong> entrance which is accessible. The entrancechosen should, <strong>in</strong> any case, be one normally used by <strong>the</strong> occupants <strong>of</strong> <strong>the</strong> build<strong>in</strong>g. Longpaths <strong>of</strong> travel are not recommended.Accessible Washrooms3.7.2.3.(1) Except as provided <strong>in</strong> Sentence (2), washrooms shall be designed to accommodatedisabled persons <strong>in</strong> comformance with <strong>the</strong> appropriate requirements <strong>in</strong> Articles 3.7.3.6.to 3.7.3.9.3.7.2.3.(2) Washrooms need not comform to <strong>the</strong> requirements <strong>in</strong> Sentence (1) provided(a) <strong>the</strong>y are located on a floor area to which barrier-free acess is not provided,(b) <strong>the</strong>y are located with<strong>in</strong> suites <strong>of</strong> residential occupancy, or(c) o<strong>the</strong>r washrooms designed to accommodate disabled persons are available <strong>in</strong> locationsprovid<strong>in</strong>g equivalent convenience.Subsection 3.7.3. Design StandardsSigns3.7.3.1.(1) Where a build<strong>in</strong>g is required to have an entrance to accommodate disabledpersons, signs <strong>in</strong>corporat<strong>in</strong>g <strong>the</strong> <strong>in</strong>ternational symbol <strong>of</strong> accessibility for disabled personsshall be <strong>in</strong>stalled where necessary to <strong>in</strong>dicate <strong>the</strong> location <strong>of</strong> that entrance.3.7.3.1.(2) Where a washroom, elevator or park<strong>in</strong>g area is required to accommodate disabledpersons, it shall be identified by a sign consist<strong>in</strong>g <strong>of</strong> <strong>the</strong> <strong>in</strong>ternational symbol <strong>of</strong> accessibilityfor disabled persons and such o<strong>the</strong>r graphic or written directions as are neededto <strong>in</strong>dicate clearly <strong>the</strong> type <strong>of</strong> facility available.15


ExplanationThe <strong>of</strong>ficial symbol, as shown below, <strong>in</strong>dicates to disabled persons that <strong>the</strong>y will havereasonable freedom <strong>of</strong> movement with<strong>in</strong> <strong>the</strong> build<strong>in</strong>g to which it is attached. It usually hasa blue background, but if, because <strong>of</strong> light<strong>in</strong>g conditions, it does not stand out, it can beset on a white-background. An arrow can be added to ei<strong>the</strong>r side or to <strong>the</strong> top or bottomto <strong>in</strong>dicate direction or <strong>the</strong> location <strong>of</strong> an accessible space or facility.JExterior Walks3.7.3.2.(1) Exterior walks that form part <strong>of</strong> a barrier-free access shall(a) have a slip-resistant, cont<strong>in</strong>uous and even surface,(b) be at least 1 100 mm <strong>in</strong> width, and(c) have a level area adjacent to <strong>the</strong> entrance doorway conform<strong>in</strong>g to Clause3.7.3.4.(1)(~).Doorways3.7.3.3.(1) Every doorway that is located <strong>in</strong> a barrier-free access shall have a clear width<strong>of</strong> at least 760 mm when <strong>the</strong> door is <strong>in</strong> <strong>the</strong> open position.3.7.3.3.(2) The doorway to at least 1 bathroom with<strong>in</strong> a suite <strong>of</strong> residential occupancyshall have a clear width <strong>of</strong> at least 760 mm when <strong>the</strong> door is <strong>in</strong> <strong>the</strong> open position.Explanat ionEven though it is required to have doors to washrooms <strong>in</strong> residential suites large enoughto permit <strong>the</strong> passage <strong>of</strong> wheelchairs, it does not mean that <strong>the</strong> washroom or its fixtureshave to be designed to facilitate persons <strong>in</strong> wheelchairs.16


3.7.3.3.(3) Thresholds for doorways <strong>in</strong> Sentences (I) and (2) shall not exceed 13 mm <strong>in</strong>height above <strong>the</strong> f<strong>in</strong>ished floor surface and shall be bevelled to facilitate <strong>the</strong> passage <strong>of</strong>wheelchairs.Door Closers3.7.3.3.(4) Except for doors to dwell<strong>in</strong>g units, door closers for doors <strong>in</strong> a barrier-freeaccess shall be designed to permit(a) doors to open when a force <strong>of</strong> not more than 38 N is applied to <strong>the</strong> handles, pushplates or latch-releas<strong>in</strong>g devices for exterior doors and not more than 22 N for<strong>in</strong>terior doors, and(b)<strong>in</strong>terior doors to have a clos<strong>in</strong>g period <strong>of</strong> at least 3 s measured from <strong>the</strong> door <strong>in</strong>an open position <strong>of</strong> 70" to <strong>the</strong> doorway to a po<strong>in</strong>t 75 mm from <strong>the</strong> closed positionmeasured from <strong>the</strong> lead<strong>in</strong>g edge <strong>of</strong> <strong>the</strong> latch side <strong>of</strong> <strong>the</strong> door.Vestibules3.7.3.3.(5) Vestibules located <strong>in</strong> a barrier-free access shall be arranged to allow <strong>the</strong> movement<strong>of</strong> wheelchairs between doors and shall(a) provide a distance between 2 doors <strong>in</strong> series <strong>of</strong> at least 1.2 m plus <strong>the</strong> width <strong>of</strong> anydoor that sw<strong>in</strong>gs <strong>in</strong>to <strong>the</strong> space <strong>in</strong> <strong>the</strong> path <strong>of</strong> travel from one door to ano<strong>the</strong>r, and(b) have a clear space, beyond <strong>the</strong> latch side <strong>of</strong> each door, <strong>of</strong> at least 600 mm when <strong>the</strong>door sw<strong>in</strong>gs <strong>in</strong>to <strong>the</strong> vestibule and at least 300 mm when <strong>the</strong> door sw<strong>in</strong>gs away from<strong>the</strong> vestibule (see explanation for 3.7.3.4.(1) (c)).Ramps3.7.3.4.(1) Ramps located <strong>in</strong> a barrier-free access shall(a) have a m<strong>in</strong>imum width <strong>of</strong> 870 mm between handrails,(b)have a maximum gradient <strong>of</strong> 1 <strong>in</strong> 12, except that a gradient not exceed<strong>in</strong>g 1 <strong>in</strong> 10is permitted where <strong>the</strong> length <strong>of</strong> ramp does not exceed 3 m,(c) have a level area <strong>of</strong> at least 1.5 by 1.5 m at <strong>the</strong> top and bottom and at <strong>in</strong>termediatelevels <strong>of</strong> a ramp lead<strong>in</strong>g to a door, so that <strong>the</strong> level area extends at least 600 mmbeyond <strong>the</strong> latch side <strong>of</strong> <strong>the</strong> door open<strong>in</strong>g, except that where <strong>the</strong> door opens awayfrom <strong>the</strong> ramp, <strong>the</strong> area extend<strong>in</strong>g beyond <strong>the</strong> latch side <strong>of</strong> <strong>the</strong> door open<strong>in</strong>g maybe reduced to 300 mm,17


-1500 mm MIN.1500 mni MIN.*P-RAMP -ADOOK SWINGS ON TO RAMPDOOR SWINGS AWAY FROM RAMPBR 6506-5(d) have a level area at least 1.2 m long and at least <strong>the</strong> same width as <strong>the</strong> ramp,(i) at <strong>in</strong>tervals <strong>of</strong> not more than 9 m along its length, and(ii) where <strong>the</strong>re is an abrupt change <strong>in</strong> <strong>the</strong> direction <strong>of</strong> <strong>the</strong> ramp, and(e) be equipped with handrails and guards comform<strong>in</strong>g to Articles 3.4.7.5. and 3.4.7.6.3.7.3.4.(2) Floors or walks <strong>in</strong> a barrier-free access hav<strong>in</strong>g a slope steeper than 1 <strong>in</strong> 20shall be designed as ramps.Elevators3.7.3.5.(1) The passenger-type elevator <strong>in</strong> Article 3.7.2.1. shall conform to Appendix E<strong>of</strong> CSA B44, “Safety <strong>Code</strong> for Elevators, Dumbwaiters, Escalators and Mov<strong>in</strong>g Walks.”3.7.3.5.(2) The passenger-type elevat<strong>in</strong>g device <strong>in</strong> Article 3.7.2.1. shall conform toCAN3-B355, “Safety <strong>Code</strong> for Elevat<strong>in</strong>g Devices for <strong>the</strong> Handicapped.”Washroom Design3.7.3.6.(1) Where a washroom is required by Article 3.7.2.3. to accommodate disabledpersons, at least 1 water closet stall or enclosure shall(a) be at least 1.5 m <strong>in</strong> width by 1.5 m <strong>in</strong> depth,(b) be equipped with a door which shall18


(i) be capable <strong>of</strong> be<strong>in</strong>g locked from <strong>the</strong> <strong>in</strong>side,(ii) provide a clear open<strong>in</strong>g <strong>of</strong> at least 760 mm with <strong>the</strong> door <strong>in</strong> <strong>the</strong> open position,(iii) sw<strong>in</strong>g outward, unless sufficient room is provided with<strong>in</strong> <strong>the</strong> stall or enclosureto permit <strong>the</strong> door to be closed without <strong>in</strong>terfer<strong>in</strong>g with <strong>the</strong> wheelchair,(iv) be provided with a door pull on <strong>the</strong> <strong>in</strong>side located so that <strong>the</strong> centrel<strong>in</strong>e isbetween 200 mm and 300 mm from <strong>the</strong> h<strong>in</strong>ged side <strong>of</strong> <strong>the</strong> door, and(v) be provided with a door pull on <strong>the</strong> outside, near <strong>the</strong> latch side <strong>of</strong> <strong>the</strong> door,(c) have a water closet located so that its centrel<strong>in</strong>e is not less than 460 mm and notmore than 480 mm from an adjacent side wall on 1 side,(d) be equipped with grab bars which shall(i) be mounted on <strong>the</strong> side wall closest to <strong>the</strong> water closet extend<strong>in</strong>g from a po<strong>in</strong>tnot more than 300 mm from <strong>the</strong> rear wall to at least 450 mm <strong>in</strong> front <strong>of</strong> <strong>the</strong>water closet seat,(ii) be mounted on <strong>the</strong> wall beh<strong>in</strong>d <strong>the</strong> water closet so that it extends <strong>the</strong> fullwidth <strong>of</strong> <strong>the</strong> toilet bowl where <strong>the</strong> water closet does not have a water tank,(iii) be mounted from 840 mm to 920 mm above <strong>the</strong> floor level,(iv) be <strong>in</strong>stalled to resist a load <strong>of</strong> at least 1.3 kN applied vertically or horizontally,(v) be not less than 30 mm and not more than 40 mm <strong>in</strong> diameter and(vi) have a clearance <strong>of</strong> 35 mm to 45 mm from <strong>the</strong> wall,(e) be equipped with a coat hook mounted not more than 1.4 m above <strong>the</strong> floor on aside wall and project<strong>in</strong>g not more than 25 mm from <strong>the</strong> wall,(f) have a clearance <strong>of</strong> at least 1.7 m between <strong>the</strong> outside <strong>of</strong> <strong>the</strong> stall face and <strong>the</strong> face<strong>of</strong> an <strong>in</strong>-sw<strong>in</strong>g<strong>in</strong>g washroom door and 1.4 m between <strong>the</strong> outside <strong>of</strong> <strong>the</strong> stall faceand any wall-mounted fixture.3.7.3.7.( 1) Water closets for disabled persons shall(a) be equipped with seats located at not less than 400 mm and not more than 460 mmabove <strong>the</strong> floor level,(b) be equipped with hand-operated flush<strong>in</strong>g controls that are easily accessible to awheelchair user,19


'(c) be equipped with a back support such as a seat lid, and(d) not have a spr<strong>in</strong>g-activated seat.ExplanationWall-mounted water closets or floor models with reced<strong>in</strong>g bases are preferable because<strong>the</strong>y provide <strong>the</strong> least amount <strong>of</strong> obstruction.3.7.3.8.( 1) Where a washroom is required to accommodate disabled persons, it shall(a) be equipped with a lavatory which shall(i) be mounted so that <strong>the</strong> distance betweeen <strong>the</strong> centrel<strong>in</strong>e <strong>of</strong> <strong>the</strong> fixture and<strong>the</strong> side wall is at least 460 mm,(ii) have a clearance <strong>of</strong> at least 660 mm beneath <strong>the</strong> bottom <strong>of</strong> <strong>the</strong> lavatory to apo<strong>in</strong>t at least 260 mm <strong>in</strong> from <strong>the</strong> front,(iii) have <strong>in</strong>sulated waste outlet pipes where <strong>the</strong> waste pipes constitute a burnhazard,(iv) have faucet handles <strong>of</strong> <strong>the</strong> lever type that are not spr<strong>in</strong>g-loaded, and(v) have no shelves or o<strong>the</strong>r projections located above it so as to create a hazard,(b) have soap and towel dispensers located not more than 1.4 m above <strong>the</strong> floor andaccessible to persons <strong>in</strong> wheelchairs.Special Washrooms3.7.3.9.(1) Where a special washroom is provided primarily for <strong>the</strong> use <strong>of</strong> disabled persons<strong>of</strong> both sexes <strong>in</strong> lieu <strong>of</strong> facilities for disabled persons <strong>in</strong> washrooms used by <strong>the</strong> generalpublic, such washrooms shall(a) be equipped with doors capable <strong>of</strong> be<strong>in</strong>g locked from <strong>the</strong> <strong>in</strong>side and released from<strong>the</strong> outside,(b) be provided with a lavatory conform<strong>in</strong>g to Article 3.7.3.8.,(c) be equipped with a water closet conform<strong>in</strong>g to Article 3.7.3.7.,(d) be equipped with grab bars conform<strong>in</strong>g to Clause 3.7.3.6.(1)(d),(e) have no dimension less than 1.7 m,20


(f) have fixture clearances conform<strong>in</strong>g to <strong>the</strong> fixture clearances described <strong>in</strong> Articles3.7.3.6. to 3.7.3.8., and(g) have a doorway conform<strong>in</strong>g to Article 3.7.3.3.Explanat ionUnobstructed areas <strong>in</strong> front <strong>of</strong> <strong>the</strong> lavatory, <strong>in</strong> front <strong>of</strong> <strong>the</strong> water closet and on 1 side <strong>of</strong><strong>the</strong> water closet are necessary for maneuverability <strong>of</strong> a wheelchair.Shower Stalls3.7.3.10( 1) Where <strong>in</strong>dividual shower stalls are provided <strong>in</strong> build<strong>in</strong>gs <strong>of</strong> assembly occupancy,at least 1 shower stall shall be provided for disabled persons which shall(a) have no dimension less than 920 mm,(b) be equipped with a h<strong>in</strong>ged seat that is not spr<strong>in</strong>g loaded,(c) be equipped with grab bars mounted approximately 900 mm above <strong>the</strong> floor on <strong>the</strong>wall opposite <strong>the</strong> seat, extend<strong>in</strong>g around at least 300 mm along <strong>the</strong> adjacent wall,(d) be equipped with pressure-balanced s<strong>in</strong>gle lever controls,(e) be equipped with a hand-held shower head with at least 1.5 m <strong>of</strong> flexible hose capable<strong>of</strong> be<strong>in</strong>g used as a fixed shower head mounted approximately 450 mm <strong>in</strong> from <strong>the</strong>front <strong>of</strong> <strong>the</strong> shower and approximately 1.2 m above <strong>the</strong> floor,(f) have a bevelled threshold not exceed<strong>in</strong>g 13 mm <strong>in</strong> height above <strong>the</strong> f<strong>in</strong>ished floor,and(g) have a slip-resistant floor.EXTRACTS FROM PART 9Handrails9.8.7.2. Except for stairs serv<strong>in</strong>g only 1 dwell<strong>in</strong>g unit, at least 1 handrail shall be cont<strong>in</strong>uousthroughout <strong>the</strong> length <strong>of</strong> <strong>the</strong> stairway, <strong>in</strong>clud<strong>in</strong>g land<strong>in</strong>gs, except where <strong>in</strong>terruptedby doorways or newels at changes <strong>in</strong> direction. (See explanation follow<strong>in</strong>g 3.4.7.5.(5).)9.8.7.3. Except for stairs serv<strong>in</strong>g only 1 dwell<strong>in</strong>g unit, handrails shall be term<strong>in</strong>ated <strong>in</strong>a manner that will not obstruct pedestrian travel or create a hazard. (See explanationfollow<strong>in</strong>g 3.4.7.5.(6).)21


9.8.7.4. Except for stairs serv<strong>in</strong>g only 1 dwell<strong>in</strong>g unit, handrails at <strong>the</strong> sides <strong>of</strong> stairs andramps shall extend horizontally at least 300 mm beyond <strong>the</strong> top and bottom <strong>of</strong> stairwaysand ramps. (See explanation follow<strong>in</strong>g 3.4.7.5.(7).)Barrier-Free Access9.9.2.7. Except as provided <strong>in</strong> Article 9.9.2.8., every build<strong>in</strong>g shall provide barrier-freeaccess <strong>in</strong> conformance with Section 3.7. Where barrier-free access is provided to any storeyabove <strong>the</strong> first storey, <strong>the</strong> requirements <strong>in</strong> Article 3.3.1.5. shall apply.9.9.2.8. Barrier-free access described <strong>in</strong> Article 9.9.2.7. need not be provided for apartmentbuild<strong>in</strong>gs without elevators or houses, <strong>in</strong>clud<strong>in</strong>g semi-detached, duplexes, triplexes,town houses, board<strong>in</strong>g houses and row houses.Obstructions <strong>in</strong> Corridors9.9.5.3. Except as permitted <strong>in</strong> Article 9.9.5.4., obstructions located with<strong>in</strong> 1 980 mm <strong>of</strong><strong>the</strong> floor shall not project horizontally more than 100 mm <strong>in</strong>to exit passageways, corridorsused by <strong>the</strong> public or public corridors <strong>in</strong> a manner that would create a hazard for visuallyimpairedpersons travell<strong>in</strong>g adjacent to walls.9.9.5.4. The horizontal projection <strong>of</strong> an obstruction <strong>in</strong> Article 9.9.5.3. is permitted toexceed 100 mm where <strong>the</strong> obstruction extends to less than 680 mm above <strong>the</strong> floor. (Seeexplanation follow<strong>in</strong>g 3.3.1.7.(4).)REFERENCES1. Build<strong>in</strong>g Standards for <strong>the</strong> Handicapped, <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> Supplement No. 7,Associate Committee on <strong>the</strong> <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong>, NRCC 8333, <strong>National</strong> ResearchCouncil <strong>of</strong> <strong>Canada</strong>, Ottawa, 1965.2. <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> <strong>of</strong> <strong>Canada</strong> 1975, Associate Committee on <strong>the</strong> <strong>National</strong>Build<strong>in</strong>g <strong>Code</strong>, NRCC 13982, <strong>National</strong> Research Council <strong>of</strong> <strong>Canada</strong>, Ottawa, 1975.3. <strong>National</strong> Build<strong>in</strong>g <strong>Code</strong> <strong>of</strong> <strong>Canada</strong> 1985, Associate Committee on <strong>the</strong> <strong>National</strong>Build<strong>in</strong>g <strong>Code</strong>, NRCC 23174, <strong>National</strong> Research Council <strong>of</strong> <strong>Canada</strong>, Ottawa, 1985.22

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!