EN | 64<strong>Dinion</strong> <strong>IP</strong> | Installation Manualonly for the duration of the preset post-alarm time and a new segmentsubsequently used in the same manner.This ensures that the alarm recorded is always secured for its entire duration andthe space required to save each alarm recording is easy to calculate.PropertiesYou can view the current properties directly in the recording scheduler andmodify them if necessary. You can also activate the alarms that should triggerrecording. Similarly, you can also select the profile for recording.CautionAll modifications result in the re-organization of the partition and the lossof all sequences on this partition. Changes to the size of a partition (Totalpartition size) lead to the entire hard drive being reorganized and the lossof all recordings stored on the drive. Consequently, you should back up allimportant sequences on the computer's hard drive.Partition nameYou can enter a new name for the partition.<strong>Bosch</strong> Security Systems | 2006-05 | V2.0