Dinion IP - NWC-0495 - Bosch
Dinion IP - NWC-0495 - Bosch Dinion IP - NWC-0495 - Bosch
Dinion IP | Installation ManualEN | 61Recording schedulerSet all parameters for recording. Recording can be performed continuously or inthe case of an alarm.Activating a partition for recordingAfter configuration, you can activate the partition for recording by clicking theStart button.After starting, the pages Continuous recording, Alarm recording and theProperties for the activated partitions are displayed in gray, and the configurationcannot be modified.The graphic in the lower section of the pages indicates this partition's recordingactivity. You will see an animated graphic while recording is taking place. Youcan terminate recording at any time and deactivate the partition.• Click the Start button to activate the currently selected partition for recording.• Click the Stop button to deactivate the currently selected partition forrecording. Recordings that are currently running will be interrupted and theconfiguration can be modified.Bosch Security Systems | 2006-05 | V2.0
EN | 62Dinion IP | Installation ManualContinuous recordingYou can specify the times during which continuous recording to the hard driveshould take place.Separate selection fields are available for each day of the week. You can select upto 16 individual recording time intervals for each day of the week.NoteIf a time interval has already been selected for alarm recording, you cannotselect it for continuous recording (see Alarm recording, page 63).• Left-click the point in the schedule at which recording should start and holdthe button down.• Drag the selected field to the desired recording end and then release themouse key.• Right-click a highlighted time interval to delete it.• Click the Select all button to highlight all time intervals.• Click the Clear all button to delete all highlighted time intervals.Recording statusThe graphic indicates the recording activity in this partition. You will see ananimated graphic while recording is taking place.Bosch Security Systems | 2006-05 | V2.0
- Page 11 and 12: EN | xDinion IP | Installation Manu
- Page 13 and 14: Dinion IP | Installation ManualEN |
- Page 15 and 16: EN | 14Dinion IP | Installation Man
- Page 17 and 18: EN | 16Dinion IP | Installation Man
- Page 19 and 20: EN | 18Dinion IP | Installation Man
- Page 21 and 22: EN | 20Dinion IP | Installation Man
- Page 23 and 24: EN | 22Dinion IP | Installation Man
- Page 25 and 26: EN | 24Dinion IP | Installation Man
- Page 27 and 28: EN | 26Dinion IP | Installation Man
- Page 29 and 30: EN | 28Dinion IP | Installation Man
- Page 31 and 32: EN | 30Dinion IP | Installation Man
- Page 33 and 34: EN | 32Dinion IP | Installation Man
- Page 35 and 36: EN | 34Dinion IP | Installation Man
- Page 37 and 38: EN | 36Dinion IP | Installation Man
- Page 39 and 40: EN | 38Dinion IP | Installation Man
- Page 41: EN | 40Dinion IP | Installation Man
- Page 45 and 46: EN | 44Dinion IP | Installation Man
- Page 47 and 48: EN | 46Dinion IP | Installation Man
- Page 49 and 50: EN | 48Dinion IP | Installation Man
- Page 51 and 52: EN | 50Dinion IP | Installation Man
- Page 53 and 54: EN | 52Dinion IP | Installation Man
- Page 55 and 56: EN | 54Dinion IP | Installation Man
- Page 57 and 58: EN | 56Dinion IP | Installation Man
- Page 59 and 60: EN | 58Dinion IP | Installation Man
- Page 61: EN | 60Dinion IP | Installation Man
- Page 65 and 66: EN | 64Dinion IP | Installation Man
- Page 67 and 68: EN | 66Dinion IP | Installation Man
- Page 69 and 70: EN | 68Dinion IP | Installation Man
- Page 71 and 72: EN | 70Dinion IP | Installation Man
- Page 73 and 74: EN | 72Dinion IP | Installation Man
- Page 75 and 76: EN | 74Dinion IP | Installation Man
- Page 77 and 78: EN | 76Dinion IP | Installation Man
- Page 79 and 80: EN | 78Dinion IP | Installation Man
- Page 81 and 82: EN | 80Dinion IP | Installation Man
- Page 83 and 84: EN | 82Dinion IP | Installation Man
- Page 85 and 86: EN | 84Dinion IP | Installation Man
- Page 87 and 88: EN | 86Dinion IP | Installation Man
- Page 89 and 90: EN | 88Dinion IP | Installation Man
- Page 91 and 92: EN | 90Dinion IP | Installation Man
- Page 93 and 94: EN | 92Dinion IP | Installation Man
- Page 95 and 96: EN | 94Dinion IP | Installation Man
- Page 97 and 98: EN | 96Dinion IP | Installation Man
- Page 99: Bosch Sicherheitssysteme GmbHLudwig
<strong>Dinion</strong> <strong>IP</strong> | Installation ManualEN | 61Recording schedulerSet all parameters for recording. Recording can be performed continuously or inthe case of an alarm.Activating a partition for recordingAfter configuration, you can activate the partition for recording by clicking theStart button.After starting, the pages Continuous recording, Alarm recording and theProperties for the activated partitions are displayed in gray, and the configurationcannot be modified.The graphic in the lower section of the pages indicates this partition's recordingactivity. You will see an animated graphic while recording is taking place. Youcan terminate recording at any time and deactivate the partition.• Click the Start button to activate the currently selected partition for recording.• Click the Stop button to deactivate the currently selected partition forrecording. Recordings that are currently running will be interrupted and theconfiguration can be modified.<strong>Bosch</strong> Security Systems | 2006-05 | V2.0