EN | 44<strong>Dinion</strong> <strong>IP</strong> | Installation ManualJPEG postingYou can save individual JPEG images on an FTP server at certain intervals. Youcan then retrieve these images at a later date to reconstruct alarm events ifrequired.JPEG formatSelect the resolution you wish the JPEG images to have:• Small 176 × 144 pixels (QCIF)• Medium 352 × 288 pixels (CIF)• Large 704 × 576 pixels (4CIF)File nameYou can select how file names will be created for the individual images which aretransmitted.• Overwrite: The same file name is always used and any existing file will beoverwritten with the current file.• Increment: A number from 000 to 255 is added to the file name andautomatically incremented by 1. When it reaches 255 it starts again from 000.• Date/time suffix: The date and time are automatically added to the filename. When setting this parameter, please ensure that the date and time ofthe unit are always correctly set. Example: the file snap021606_124530.jpgwas stored on February 16, 2006 at 12.45 p.m. and 30 seconds.JPEG posting intervalEnter the interval in seconds at which the images will be sent to an FTP server.Enter zero if you do not want any images to be sent.<strong>Bosch</strong> Security Systems | 2006-05 | V2.0