13.07.2015 Views

Operating Manual - KLARO GmbH

Operating Manual - KLARO GmbH

Operating Manual - KLARO GmbH

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Operating</strong> <strong>Manual</strong> for SBR small wastewater treatment systemsKLbasic controlKLplus control<strong>Manual</strong>operationHh:mm dddd-mm-jjVacationinputRead outerrorsAdjustments:OperatiocodeServicemenu<strong>Manual</strong> driving of the valvesCurrent time, day and date. Can be set using SET.Setting the vacation mode (max. 90 days)Here, operational breakdowns are saved and can beread out. Using , you can switch between the errormessage and the corresponding date.By means of the arrow keys, the current setting can bedisplayed.For specialist personnelFor specialist personnelmanualoperationDateTimeVacation oper.Read outold errorsSetupreportoperation codeservice codeenter5.2.1. Querying the operating hoursPress the key. The following display appearson the screen:Press theappears on the screen:key. The following displayOperationhours<strong>Operating</strong> hoursmeter readingBy pressing again, the operating hours for By pressing again, the number ofthe valves 1-4 can be called one after the other operating hours of valve 1 (feed) are shown.by means of the arrow keys . Then, the By pressing the arrow keys , youtotal operating hours of the compressor are can call the operating hours of the othershown.valves, of the compressor, of the UV lampBy pressing once, you can return to theand the pump for the phosphate precipitationone after the other. Moreover, the capacitydisplay “Show operating hours“. By pressing ,of the plant is shown.you can access the menu “<strong>Manual</strong> mode“.By pressing once, you can return to themaintenance level. By pressing this keyagain, you can return to the automatic mode. Note: If no key has been pressed for 10 minutes, the normal mode is automatically set.5.2.2. Driving the valves and the cabinet fan manually by means of the “<strong>Manual</strong> mode“When checking the valves, each valve should run at least five seconds, since the monitoring ofthe power consumption of the valves takes some time until a possible fault is detected.Following the valves, the cabinet fan, if any, can also be driven and checked.<strong>KLARO</strong> <strong>GmbH</strong> 17

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!