13.07.2015 Views

CompuScope SDK Manua.. - Egmont Instruments

CompuScope SDK Manua.. - Egmont Instruments

CompuScope SDK Manua.. - Egmont Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

imped_aimped_bexternal_clock_adjusttrigger_stepboard_versionee_optionsindex_offsetsample_offset_32sample_resolution_32diff_input_adiff_input_bmultiple_record_countreal_time_activetrigger_enable_controlinput impedance for channel A. To set, “OR” eitherGAGE_1_MOHM_INPUT or GAGE_50_OHM_INPUT with the inputrange when setting the range with a call to gage_input_control_2routine.input impedance for channel B. To set , “OR” eitherGAGE_1_MOHM_INPUT or GAGE_50_OHM_INPUT with the inputrange when setting the range with a call to gage_input_control_2routine.value used to adjust trigger address when external clock is used.value used to determine trigger resolution.version of the current <strong>CompuScope</strong> hardware.available options for the current <strong>CompuScope</strong> hardware. The optionsare represented by one or more constants “ORed” together. Theavailable constants are defined in EEPROM.HThis parameter is used primarily in the driver. The offset, in bytes, isthe offset between the address register and the data register of the<strong>CompuScope</strong> hardware.index_offset == 0 if the hardware uses flat addressing (e.g. CS8500).index_offset == 4 if the hardware uses indexed addressing and theregisters are 1 D-word wide (e.g. CS12100 andCS1250 analog or add-on section only).index_offset == 1 if the hardware uses indexed addressing and theregisters are 1 byte wide (e.g. most other <strong>CompuScope</strong>models).This does not apply to the CP500 base board which uses flataddressing.Same as “sample_offset” but it is a 32 bit number to better support16 bit and higher resolution A/D boards.Same as “sample_resolution” but it is a 32 bit number to better support16 bit and higher resolution A/D boards.Set if channel A is in differential input mode. To set, “OR” the inputrange with GAGE_DIFFERENTIAL_INPUT and to clear “OR” withGAGE_SINGLE_ENDED_INPUT when setting the range with a callto the gage_input_control_2 routine.Set if channel B is in differential input mode. To set, “OR” the inputrange with GAGE_DIFFERENTIAL_INPUT and to clear “OR” withGAGE_SINGLE_ENDED_INPUT when setting the range with a callto the gage_input_control_2 routine.The current multiple record count as set by a call togage_multiple_record_acquisitions_32 routine.The real_time_active parameter indicates if the <strong>CompuScope</strong> driver isin the real-time modeThe trigger_enable_control parameter indicates whether the triggercircuitry is enabled or disabled. In order to ensure pretrigger datacapability, the <strong>CompuScope</strong> hardware should have this capability.<strong>CompuScope</strong> <strong>SDK</strong> <strong>Manua</strong>l Appendix A Page 59

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!