13.07.2015 Views

CompuScope SDK Manua.. - Egmont Instruments

CompuScope SDK Manua.. - Egmont Instruments

CompuScope SDK Manua.. - Egmont Instruments

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Description of Parameters for gage_driver_info_type StructureValues of the constants used below can be found in GAGE_DRV.H or in GAGE_LOW.H file.indexsegmentBoard_typemax_memorymax_available_memorybank_offset_valuemodeenable_aenable_bratemultipliercoupling_acoupling_extgain_again_bgain_exttrigger_depthbase I/O port index of <strong>CompuScope</strong>, used to transfer data from the<strong>CompuScope</strong> card. The value is typically read from the configurationfile GAGESCOP.INC. For PCI <strong>CompuScope</strong> boards, the value is0xffff.absolute address of memory segment, typically read fromGAGESCOP.INC. For PCI <strong>CompuScope</strong> boards, the value is 0xffff.numeric constant representing the board type as defined in theGAGE_DRV.H file.memory size of <strong>CompuScope</strong> board (in samples).available memory (in samples) in current mode, i.e. max_memory insingle channel, max_memory / 2 in dual channel.block number where the data for channel B starts.current mode of the board, which can be GAGE_SINGLE_CHAN orGAGE_DUAL_CHAN or GAGE_QUAD_CHAN. Mode is set bygage_capture_mode routine.current enable status of channel A. On board <strong>CompuScope</strong> memory iseither connected or disconnected to the transceiver by callinggage_input_control routine with either GAGE_INPUT_ENABLE orGAGE_INPUT_DISABLE.current enable status of channel B. On board <strong>CompuScope</strong> memory iseither connected or disconnected to the transceiver by callinggage_input_control routine with either GAGE_INPUT_ENABLE orGAGE_INPUT_DISABLE.set by gage_capture_mode routine.set by gage_capture_mode routine. The constants are GAGE_HZ,GAGE_KHZ, GAGE_MHZ, GAGE_GHZ and GAGE_EXT_CLK.status of the coupling for channel A, either GAGE_AC or GAGE_DC.status of the coupling for the external trigger. Use GAGE_AC orGAGE_DC with gage_trigger_control_2 routine.status of the gain value for channel A. One of the predefined constants,such as GAGE_PM_5_V, defined in GAGE_DRV.H file should beused with gage_input_control routine to set this parameter:status of the gain value for channel B. One of the predefined constants,such as GAGE_PM_1_V, defined in GAGE_DRV.H file should beused with gage_input_control routine to set this parameter:status of the gain for the external trigger. To set, use eitherGAGE_PM_5_V or GAGE_PM_1_V with gage_trigger_control_2routine.number of points captured after the trigger event set bygage_trigger_control_2 routine.<strong>CompuScope</strong> <strong>SDK</strong> <strong>Manua</strong>l Appendix A Page 57

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!