User Manual M3000® Automation System / MSC II (Moog Servo ...
User Manual M3000® Automation System / MSC II (Moog Servo ...
User Manual M3000® Automation System / MSC II (Moog Servo ...
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
10 <strong>MSC</strong> <strong>II</strong> (<strong>Moog</strong> <strong>Servo</strong> Controller) License Key<br />
10.6.2 CANopen Node-ID and IP Address<br />
The CANopen node-ID of the <strong>MSC</strong> <strong>II</strong> control module's CAN bus interfaces<br />
and the IP-address of the <strong>MSC</strong> <strong>II</strong> control module's Ethernet interface are<br />
saved in the license key.<br />
The CANopen node-ID and IP-address can be set or modified in the following<br />
places:<br />
• In the application program<br />
• With the PLC Browser in the MACS development environment<br />
The IP-address is read from the license key only when the power supply is<br />
switched on or when the <strong>MSC</strong> <strong>II</strong> control module is reset.<br />
The default license key settings are:<br />
• IP address: 10.49.40.1<br />
• CANopen node-ID: 127<br />
10.6.3 Mounting and Removing<br />
Attachment Screw<br />
Figure 55: License Key of the <strong>MSC</strong> <strong>II</strong> control module with Attachment Screws<br />
10.6.3.1 Required Tool<br />
The following tool is required to mount and remove the license key:<br />
• 3 mm screwdriver<br />
10.6.3.2 Mounting the License Key<br />
Attachment Screw<br />
WARNING The license key may be inserted or removed only when<br />
the <strong>MSC</strong> <strong>II</strong> control module is powered down!<br />
Attempting to insert or remove the license key during operation<br />
might damage the license key or the <strong>MSC</strong> <strong>II</strong> control module<br />
permanently.<br />
WARNING If an M3000 ® module is to be taken out of operation, the<br />
entire system must always be shut down and disconnected<br />
from all power supplies.<br />
Therefore, all power supplies must be switched off, including<br />
those from attached peripherals such as externally<br />
supplied transmitters, programming devices, etc.!<br />
The M3000 ® module must be protected against unintentional<br />
restarting!<br />
If the M3000 ® module is connected to other devices and/ or<br />
facilities, always consider the full consequences and take appropriate<br />
precautions before switching off the module.<br />
CAUTION When using a screwdriver, use caution to avoid slipping and<br />
causing personal injury or damage to the <strong>MSC</strong> <strong>II</strong> control<br />
module.<br />
License Key of the <strong>MSC</strong> <strong>II</strong><br />
control module: CANopen<br />
Node-ID and IP Address<br />
License Key of the <strong>MSC</strong> <strong>II</strong><br />
control module with<br />
Attachment Screws<br />
License Key of the <strong>MSC</strong> <strong>II</strong><br />
control module: Tool<br />
required for Mounting and<br />
Removing<br />
Mounting the License<br />
Key: Safety Instructions<br />
© <strong>Moog</strong> GmbH <strong>User</strong> <strong>Manual</strong> M3000 ® and <strong>MSC</strong> <strong>II</strong> (CA65865-001; Version 1.1, 08/08) 86