02.12.2012 Views

User Manual M3000® Automation System / MSC II (Moog Servo ...

User Manual M3000® Automation System / MSC II (Moog Servo ...

User Manual M3000® Automation System / MSC II (Moog Servo ...

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

5 Mechanical Installation DIN Rail Modules<br />

Cable Conduit<br />

X1 X3<br />

X2<br />

WCAN<br />

X4<br />

L1+ TRM I/O1 I/O2 I/O3 I/O4 WCAN LCAN EBus Rx Tx Aux1 Aux2 Aux3 Aux4 OutEN<br />

1 2 3 4 5 6 7 8 9<br />

L1+ L1+ M1 M1 L2+ L2+ M2 M2 M2 X2<br />

X1<br />

X3<br />

OutEn I/O1 I/O2 I/O3 I/O4 M2 M2 M2 M2 X4<br />

WCAN WCAN<br />

Run<br />

X13<br />

X14<br />

X15 X16<br />

Stop !<br />

LAN RT-ETH1 RT-ETH2<br />

Reset<br />

X11 X12<br />

USB1 USB2 Link 100MB/s Link 100MB/s Link 100MB/s<br />

LK<br />

SIO F-Bus<br />

1 2 3 4 5 6 7 8 9 10<br />

X6<br />

X7<br />

X5 CLK+ CLK- A+ A- B+ B- Z+ Z- +5V DGND X8<br />

X9<br />

X10<br />

A1 B1 Z1 A2 B2 Z2 A3 B3 Z3 A4 B4 Z4 LED1 LED2 LED3 Error<br />

X5 S1<br />

X8<br />

X6 S2<br />

X7<br />

1<br />

� 30 mm (1.18 in)<br />

WCAN<br />

1 10<br />

Off On<br />

S3<br />

S4<br />

SIO F-Bus<br />

1 1<br />

X9 X10<br />

10<br />

X1 X3<br />

X2<br />

WCAN<br />

X4<br />

L1+ TRM I/O1 I/O2 I/O3 I/O4 WCAN LCAN EBus Rx Tx Aux1 Aux2 Aux3 Aux4 OutEN<br />

1 2 3 4 5 6 7 8 9<br />

L1+ L1+ M1 M1 L2+ L2+ M2 M2 M2 X2<br />

X1<br />

X3<br />

OutEn I/O1 I/O2 I/O3 I/O4 M2 M2 M2 M2 X4<br />

WCAN WCAN<br />

Run<br />

X13<br />

X14<br />

X15 X16<br />

Stop !<br />

LAN RT-ETH1 RT-ETH2<br />

Reset<br />

X11 X12<br />

USB1 USB2 Link 100MB/s Link 100MB/s Link 100MB/s<br />

LK<br />

SIO F-Bus<br />

1 2 3 4 5 6 7 8 9 10<br />

X6<br />

X7<br />

X5 CLK+ CLK- A+ A- B+ B- Z+ Z- +5V DGND X8<br />

X9<br />

X10<br />

A1 B1 Z1 A2 B2 Z2 A3 B3 Z3 A4 B4 Z4 LED1 LED2 LED3 Error<br />

X5 S1<br />

X8<br />

X6 S2<br />

X7<br />

1<br />

� 30 mm (1.18 in)<br />

SIO F-Bus<br />

1 1<br />

X9 X10<br />

10<br />

Figure 18: Arrangement of DIN Rail Modules between Cable Conduits<br />

If shielding is required for the signal cables, make sure the distance between<br />

the DIN rail modules and the cable conduit is sufficiently large.<br />

Shielding Bar<br />

Detail Enlargement:<br />

� Figure 19<br />

Shield<br />

Insulating<br />

Bar Holder<br />

Figure 19: Using a Shielding Bar when Connecting a Signal Cable to the <strong>MSC</strong> <strong>II</strong><br />

(Detail from figure 18)<br />

WCAN<br />

1 10<br />

Off On<br />

S3<br />

S4<br />

X5 S1<br />

X8<br />

X6 S2<br />

X7<br />

1<br />

1 10<br />

Off On<br />

S3<br />

S4<br />

1 1 10<br />

SIO F-Bus<br />

X9 X10<br />

Signal Cable<br />

Cable Conduit<br />

Shield Connection Terminals<br />

(e.g.: Phoenix Type SK 8)<br />

Insulating<br />

Bar Holder<br />

Arrangement of<br />

DIN Rail Modules<br />

between Cable Conduits<br />

Using a Shielding Bar<br />

when Connecting a<br />

Signal Cable to the<br />

<strong>MSC</strong> <strong>II</strong><br />

© <strong>Moog</strong> GmbH <strong>User</strong> <strong>Manual</strong> M3000 ® and <strong>MSC</strong> <strong>II</strong> (CA65865-001; Version 1.1, 08/08) 32<br />

� 30 mm<br />

(1.18 in)<br />

� 30 mm<br />

(1.18 in)