2 Safety Instructions Safety Instructions<br />
2.2.9 Run/Stop/Reset<br />
WARNING If the most recent status in the online mode (MACS<br />
logged in) was 'Run' before the <strong>MSC</strong> <strong>II</strong> control module<br />
was switched off or reset, the boot project will always be<br />
started after the <strong>MSC</strong> <strong>II</strong> control module is switched back<br />
on or reset.<br />
This will occur regardless of which application program was<br />
previously running.<br />
In other words, the application program that will be started<br />
automatically after the <strong>MSC</strong> <strong>II</strong> control module is switched on<br />
or reset might be different from the application program that<br />
was executing immediately prior.<br />
More on this subject: �-"10.7-Run/Stop/Reset Switch" on page 88<br />
2.2.10 Switching Back on or Resetting the <strong>MSC</strong> <strong>II</strong><br />
WARNING If the most recent status in the online mode (MACS<br />
logged in) was 'Run' before the <strong>MSC</strong> <strong>II</strong> control module<br />
was switched off or reset, the boot project will always be<br />
started after the <strong>MSC</strong> <strong>II</strong> control module is switched back<br />
on or reset.<br />
This will occur regardless of which application program was<br />
previously running.<br />
In other words, the application program that will be started<br />
automatically after the <strong>MSC</strong> <strong>II</strong> control module is switched on<br />
or reset might be different from the application program that<br />
was executing immediately prior.<br />
More on this subject:<br />
�-"10.8.1-Behavior at Switching on and Switching off" on page 89<br />
2.2.11 'Outputs Enabled' Output of the <strong>MSC</strong> <strong>II</strong><br />
WARNING If there is a defect in an output stage, the 'Outputs Enabled'<br />
signal will not necessarily shut down all of the<br />
outputs securely.<br />
More on this subject:<br />
�-"10.17.2-'Outputs Enabled' Output (LED «OutEN»)" on page 111<br />
Safety Instructions:<br />
Run/Stop/Reset<br />
Safety Instructions:<br />
Switching Back on or<br />
Resetting the <strong>MSC</strong> <strong>II</strong><br />
Safety Instructions:<br />
'Outputs Enabled' Output<br />
of the <strong>MSC</strong> <strong>II</strong><br />
© <strong>Moog</strong> GmbH <strong>User</strong> <strong>Manual</strong> M3000 ® and <strong>MSC</strong> <strong>II</strong> (CA65865-001; Version 1.1, 08/08) 12