2 Safety Instructions Safety Instructions<br />

2.2.9 Run/Stop/Reset<br />

WARNING If the most recent status in the online mode (MACS<br />

logged in) was 'Run' before the <strong>MSC</strong> <strong>II</strong> control module<br />

was switched off or reset, the boot project will always be<br />

started after the <strong>MSC</strong> <strong>II</strong> control module is switched back<br />

on or reset.<br />

This will occur regardless of which application program was<br />

previously running.<br />

In other words, the application program that will be started<br />

automatically after the <strong>MSC</strong> <strong>II</strong> control module is switched on<br />

or reset might be different from the application program that<br />

was executing immediately prior.<br />

More on this subject: �-"10.7-Run/Stop/Reset Switch" on page 88<br />

2.2.10 Switching Back on or Resetting the <strong>MSC</strong> <strong>II</strong><br />

WARNING If the most recent status in the online mode (MACS<br />

logged in) was 'Run' before the <strong>MSC</strong> <strong>II</strong> control module<br />

was switched off or reset, the boot project will always be<br />

started after the <strong>MSC</strong> <strong>II</strong> control module is switched back<br />

on or reset.<br />

This will occur regardless of which application program was<br />

previously running.<br />

In other words, the application program that will be started<br />

automatically after the <strong>MSC</strong> <strong>II</strong> control module is switched on<br />

or reset might be different from the application program that<br />

was executing immediately prior.<br />

More on this subject:<br />

�-"10.8.1-Behavior at Switching on and Switching off" on page 89<br />

2.2.11 'Outputs Enabled' Output of the <strong>MSC</strong> <strong>II</strong><br />

WARNING If there is a defect in an output stage, the 'Outputs Enabled'<br />

signal will not necessarily shut down all of the<br />

outputs securely.<br />

More on this subject:<br />

�-"10.17.2-'Outputs Enabled' Output (LED «OutEN»)" on page 111<br />

Safety Instructions:<br />

Run/Stop/Reset<br />

Safety Instructions:<br />

Switching Back on or<br />

Resetting the <strong>MSC</strong> <strong>II</strong><br />

Safety Instructions:<br />

'Outputs Enabled' Output<br />

of the <strong>MSC</strong> <strong>II</strong><br />