10 <strong>MSC</strong> <strong>II</strong> (<strong>Moog</strong> <strong>Servo</strong> Controller) Serial Interfaces<br />

10.16 Serial Interfaces<br />

The <strong>MSC</strong> <strong>II</strong> provides the following serial interface:<br />

• SIO interface with «SIO» front panel connector<br />

SIO interface according to TIA/EIA 232 (previously RS 232):<br />

The SIO interface's communication parameters are set in the application<br />

program.<br />

Terminal assignment of the serial interfaces:<br />

�-"10.4.1-Terminal Assignment" on page 78<br />

Serial interface cables:<br />

�-"7.4-Serial TIA/EIA Interface Cables" on page 54<br />

10.17 Safety Functions<br />

10.17.1 Watchdog<br />

The <strong>MSC</strong> <strong>II</strong> control module provides a function for monitoring whether the<br />

software is working properly. When there is a fault, this function switches all<br />

digital outputs to zero potential condition and stops fieldbus communication.<br />

As a result, the user can set up systems that have a greatly reduced risk of<br />

fatal malfunctions.<br />

In the <strong>MSC</strong> <strong>II</strong> control module, this function is implemented in the<br />

M_WATCHDOG function block, which can be used in the application program<br />

to be monitored. If this function block is used, it must be enabled and triggered<br />

cyclically in order to keep the outputs enabled.<br />

When there is a fault (when the application program can no longer trigger the<br />

function block within the set time period), the outputs will be disabled.<br />

If the M_WATCHDOG function block is not used in the application program,<br />

the <strong>MSC</strong> <strong>II</strong> control module's watchdog will not operate. In this case, the outputs<br />

will always be enabled and they will output the value calculated in the<br />

application program.<br />

The digital output 'Outputs Enabled' indicates the enabled state of all<br />

digital outputs and the <strong>MSC</strong> <strong>II</strong>’s E-bus and fieldbus communication.<br />

10.17.2 'Outputs Enabled' Output (LED «OutEN»)<br />

WARNING If there is a defect in an output stage, the 'Outputs Enabled'<br />

signal will not necessarily shut down all of the<br />

outputs securely.<br />

The digital output 'Outputs Enabled' indicates the enabled state of all digital<br />

outputs and the <strong>MSC</strong> <strong>II</strong>’s E-bus and fieldbus communication. It can be used<br />

to signalize another controller that all of the <strong>MSC</strong> <strong>II</strong> control module's outputs<br />

were disabled.<br />

Serial Interfaces<br />

of the <strong>MSC</strong> <strong>II</strong><br />

Watchdog of the <strong>MSC</strong> <strong>II</strong><br />

control module<br />

'Outputs Enabled' Output<br />

(LED «OutEN») of the<br />

<strong>MSC</strong> <strong>II</strong> control module<br />

© <strong>Moog</strong> GmbH <strong>User</strong> <strong>Manual</strong> M3000 ® and <strong>MSC</strong> <strong>II</strong> (CA65865-001; Version 1.1, 08/08) 111