10 <strong>MSC</strong> <strong>II</strong> (<strong>Moog</strong> <strong>Servo</strong> Controller) Digital I/Os<br />

10.10.4.4 U/I Working Ranges<br />

Figure 59: U/I Working Ranges of <strong>MSC</strong> <strong>II</strong> control module's Digital Inputs (Current Consuming)<br />

Input voltage (DC) of the external power supply L2+ rated voltage Ue = 24 V<br />

upper limit Ue max = 36 V<br />

lower limit Ue min = 18 V<br />

Limits for the 1 state upper limit UHmax = 30 V<br />

IHmax = 15 mA<br />

lower limit UHmin = 15 V<br />

IHmin = 2 mA<br />

Limits for the 0 state upper limit ULmax = 15/5 V<br />

ILmax = 0.5/15 mA<br />

lower limit ULmin = -3 V<br />

ILmin = ND<br />

Table 20: U/I Working Ranges of <strong>MSC</strong> <strong>II</strong> control module's Digital Inputs (Current Consuming)<br />

10.10.4.5 Insulation Resistance<br />

Insulation resistance<br />

Rated voltage: 0–50 V DC<br />

Test voltage for 2,000 m (2,187 yd) operating elevation: 500 V DC<br />

U/I Working Ranges of<br />

<strong>MSC</strong> <strong>II</strong> control module's<br />

Digital Inputs (Current<br />

Consuming)<br />

Insulation Resistance<br />

of <strong>MSC</strong> <strong>II</strong> control<br />

module's Digital Inputs<br />