8.5 Reading Lamp Replacement InformationDue to the circuit complexity, critical alignment procedures, and testequipment required - The read lamp should only be replaced by X-Riteor an authorized X-Rite Service Center.The lamp is monitored for intensity, and failure warnings will bedisplayed if a problem occurs.The lamp should last approximately 500,000 measurements and iscovered by a one year limited warranty. Refer to the Limited Warrantystatement on page iii.8-5
8.6 Troubleshooting TipsInstrument will not turn On (on display):Power switch off (battery operation only).Batteries are very low and in need of charge.Contact X-Rite or Authorized Service Center.Instrument will display but not measure:Battery pack not installed.Contact X-Rite or Authorized Service Center.Incorrect measurement data continually displays:Check standard material.Calibrate instrument (see Sec. 3).Clean optics (see Sec. 8).Contact X-Rite or Authorized Service Center.Measurement drifts:Clean optics (see Sec. 8).Calibrate instrument (see Sec. 3).Contact X-Rite or Authorized Service Center.Instrument will not calibrate properly:Calibration standard needs to be cleaned (see Sec. 3).Clean optics (see Sec. 8).Contact X-Rite or Authorized Service Center.8-6
- Page 27 and 28: Positioning the Instrument on the W
- Page 29 and 30: 3.3 Calibration ProcedureTo perform
- Page 31 and 32: Calibration Procedure . . . continu
- Page 33 and 34: 4.2 Illuminant/Observer SelectionTh
- Page 35 and 36: Reference Entry . . . continued5) M
- Page 37 and 38: Sample Measurement . . . continued4
- Page 39 and 40: Using Measurement Averaging . . . c
- Page 41 and 42: Adjusting Tolerance Values . . . co
- Page 43 and 44: Adjusting Tolerance Values . . . co
- Page 45 and 46: 5.2 Pass/Fail MeasurementThe Pass/F
- Page 47 and 48: SECTION 6STORAGE OPERATIONSubjects
- Page 49 and 50: Storing Measurements . . . continue
- Page 51 and 52: Deleting Stored Measurements . . .
- Page 53 and 54: 6.3 Printing Stored MeasurementsThe
- Page 55 and 56: Printing Stored Measurements . . .
- Page 57 and 58: Tagging and Storing Operation . . .
- Page 59 and 60: Tagging and Storing Operation . . .
- Page 61 and 62: 6.5 QA-Master ‘‘Run Job’’ O
- Page 63 and 64: Setting RS-232 Communication Option
- Page 65 and 66: 7.2 Setting Operation OptionsThere
- Page 67 and 68: Setting Operation Options . . . con
- Page 69 and 70: Setting Operation Options . . . con
- Page 71 and 72: Setting Printout Options . . . cont
- Page 73 and 74: 7.4 Setting Date And TimeThe date a
- Page 75 and 76: 8.2 Cleaning the OpticsThe optics s
- Page 77: 8.4 Replacing the Target Window☛
- Page 81 and 82: 9.2 Scanning a Bar CodeFollow these
- Page 83 and 84: Troubleshooting . . . continuedWas
- Page 85 and 86: Technical Specifications . . . cont
- Page 87 and 88: Display Messages . . . continuedCal
- Page 89 and 90: APPENDIX - DCOLOR CHECKThe color ch
- Page 91 and 92: COLOR CHECK RECORDDate: Illuminant:
8.6 Troubleshooting TipsInstrument will not turn On (on display):Power switch off (battery operation only).Batteries are very low and in need of charge.Contact X-<strong>Rite</strong> or Authorized Service Center.Instrument will display but not measure:Battery pack not installed.Contact X-<strong>Rite</strong> or Authorized Service Center.Incorrect measurement data continually displays:Check standard material.Calibrate instrument (see Sec. 3).Clean optics (see Sec. 8).Contact X-<strong>Rite</strong> or Authorized Service Center.Measurement drifts:Clean optics (see Sec. 8).Calibrate instrument (see Sec. 3).Contact X-<strong>Rite</strong> or Authorized Service Center.Instrument will not calibrate properly:Calibration standard needs to be cleaned (see Sec. 3).Clean optics (see Sec. 8).Contact X-<strong>Rite</strong> or Authorized Service Center.8-6