SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
7.3 Setting Printout OptionsSetting the printout options will determine what information will betransmitted out the RS-232 port after a measurement. Listed below are theavailable options that can be set.Printout Format - determines if the measurement data is output in‘‘Spectral Data’’ (400nm - 700nm in 10nm increments), or ‘‘Color SpaceData’’ (L*a*b*, etc.). Factory default is ‘‘Color Space Data.’’Header Operation - enables or disables the header (L*a*b*, etc.) fromprinting during a data transmit. Factory default setting is ‘‘Disabled.’’Reference Operation - enables or disables the reference data fromprinting (if any) during a data transmit. Factory default setting is‘‘Disabled.’’To set printout options:1) Press [menu] key #1 twice to enterMENU PAGE 2.L* 94.10 INCLUDEDC* 21.88h 193.97menu L*C*h D65 10 difKey#1 Key#2 Key#3 Key#4Press TwiceMENU PAGE 22) Press [cnfg] key #3 to enterconfiguration functions.exit cal cnfgKey#1 Key#2 Key#3 Key#4Press7-9➩
Setting Printout Options . . . continued3) Press the [↓] key #3 or [↑] key #4to select Printout Options, thenpress [yes] key #2.CHANGE OPTIONS FOR:PRINTOUT?exit yes selectKey#1 Key#2 Key#3 Key#4PressPress orPress4) Select the printout format bypressing the [↓] key #2 or [↑] key#3. The available settings are:‘‘COLOR SPACE DATA’’ or‘‘SPECTRAL DATA.’’- Press [next] key #4 to advance tothe next option.5) Set the header printout to Enabledor Disabled. Press [on] key #2 toprint header (enabled), or press[off] key #3 to disable headerprint.6) Set the reference printout toEnabled or Disabled. Press [on]key #2 to print reference(enabled), or press [off] key #3 todisable reference print.- Press the [exit] key #1 once toreturn to Printout Options mainmenu, or press key #1 twice toreturn to normal operation.PRINTOUT FORMAT =COLOR SPACE DATAexitselectnextKey#1 Key#2 Key#3 Key#4HEADER PRINTOUT =DISABLEDexitnextKey#1 Key#2 Key#3 Key#4ENABLEDDISABLEDREFERENCE PRINTOUT =DISABLEDexitSPECTRALCOLOR SPACEononoffoffnextKey#1 Key#2 Key#3 Key#4ENABLEDDISABLED7-10➩
- Page 20 and 21: 1.6 Menu Page SelectionThe main men
- Page 22 and 23: SECTION 2INSTRUMENT POSITIONING &ME
- Page 24: Instrument Positioning & Measuremen
- Page 27 and 28: Positioning the Instrument on the W
- Page 29 and 30: 3.3 Calibration ProcedureTo perform
- Page 31 and 32: Calibration Procedure . . . continu
- Page 33 and 34: 4.2 Illuminant/Observer SelectionTh
- Page 35 and 36: Reference Entry . . . continued5) M
- Page 37 and 38: Sample Measurement . . . continued4
- Page 39 and 40: Using Measurement Averaging . . . c
- Page 41 and 42: Adjusting Tolerance Values . . . co
- Page 43 and 44: Adjusting Tolerance Values . . . co
- Page 45 and 46: 5.2 Pass/Fail MeasurementThe Pass/F
- Page 47 and 48: SECTION 6STORAGE OPERATIONSubjects
- Page 49 and 50: Storing Measurements . . . continue
- Page 51 and 52: Deleting Stored Measurements . . .
- Page 53 and 54: 6.3 Printing Stored MeasurementsThe
- Page 55 and 56: Printing Stored Measurements . . .
- Page 57 and 58: Tagging and Storing Operation . . .
- Page 59 and 60: Tagging and Storing Operation . . .
- Page 61 and 62: 6.5 QA-Master ‘‘Run Job’’ O
- Page 63 and 64: Setting RS-232 Communication Option
- Page 65 and 66: 7.2 Setting Operation OptionsThere
- Page 67 and 68: Setting Operation Options . . . con
- Page 69: Setting Operation Options . . . con
- Page 73 and 74: 7.4 Setting Date And TimeThe date a
- Page 75 and 76: 8.2 Cleaning the OpticsThe optics s
- Page 77 and 78: 8.4 Replacing the Target Window☛
- Page 79 and 80: 8.6 Troubleshooting TipsInstrument
- Page 81 and 82: 9.2 Scanning a Bar CodeFollow these
- Page 83 and 84: Troubleshooting . . . continuedWas
- Page 85 and 86: Technical Specifications . . . cont
- Page 87 and 88: Display Messages . . . continuedCal
- Page 89 and 90: APPENDIX - DCOLOR CHECKThe color ch
- Page 91 and 92: COLOR CHECK RECORDDate: Illuminant:
7.3 Setting Printout OptionsSetting the printout options will determine what information will betransmitted out the RS-232 port after a measurement. Listed below are theavailable options that can be set.Printout Format - determines if the measurement data is output in‘‘Spectral Data’’ (400nm - 700nm in 10nm increments), or ‘‘Color SpaceData’’ (L*a*b*, etc.). Factory default is ‘‘Color Space Data.’’Header Operation - enables or disables the header (L*a*b*, etc.) fromprinting during a data transmit. Factory default setting is ‘‘Disabled.’’Reference Operation - enables or disables the reference data fromprinting (if any) during a data transmit. Factory default setting is‘‘Disabled.’’To set printout options:1) Press [menu] key #1 twice to enterMENU PAGE 2.L* 94.10 INCLUDEDC* 21.88h 193.97menu L*C*h D65 10 difKey#1 Key#2 Key#3 Key#4Press TwiceMENU PAGE 22) Press [cnfg] key #3 to enterconfiguration functions.exit cal cnfgKey#1 Key#2 Key#3 Key#4Press7-9➩