SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
Deleting Stored Measurements . . . continuedDelete All3) Press [all] key #2.SELECTDELETE MODEexit all group lastKey#1 Key#2 Key#3 Key#44) Press [yes] key #4 to clear allstored data in all groups.DELETE EVERYTHING?noyesKey#1 Key#2 Key#3 Key#4- ‘‘ALL DATA CLEARED’’ isdisplayed.ALL DATA CLEARED5) ‘‘RESET GROUPS TODEFAULTS?’’ is displayed.- Press [no] key #1 to keep presetgroup names (i.e., names set inQA-Master). Press [yes] key #4 toreset names to factory defaults(i.e., Data Group 1, etc.).6) Press [exit] key #1 to exit deletemode.noRESET GROUPSTO DEFAULTS ?yesKey#1 Key#2 Key#3 Key#4exitALL GROUPSSET TO DEFAULTSSELECTDELETE MODEallgrouplastKey#1 Key#2 Key#3 Key#4Press6-6
6.3 Printing Stored MeasurementsThe SP88/SP98 has the ability to output stored measurement data directlyto a serial printer or a computer. The format that data gets printed in iscontrolled by the Printout Options select in Section 7.3.The measurement data that is printed depends on what Storage Optionis selected in Operation Options (Section 7.2).To print stored measurements:1) Refer to Section 7 to set RS-232 and Printout Options, if required.2) In storage mode, press [edit] key#4 to enter ‘‘SELECT EDITOPTION’’ screen.DATA GROUP 1STORED: 6STORES REMAINING: 993menu view next editKey#1 Key#2 Key#3 Key#43) Press [print] key #3 to enter‘‘SELECT PRINT MODE’’ screen.SELECT EDIT OPTIONexitdelprintKey#1 Key#2 Key#3 Key#4There are three modes of printthat can be accessed during storeddata printout.Print Last - will print the data ofthe last measurement taken inthe selected group.Print Group - will print allmeasurements that arecurrently in the selected group.The group printout function willalso printout the "Group #" foreach group that has data.Print All - all measurementsthat are stored will be printed.6-7exitSELECTPRINT MODEallgrouplastKey#1 Key#2 Key#3 Key#4SeePrint All SeePrint GroupSeePrint Last➩
- Page 2 and 3: WARNING: Shielded interface cables
- Page 4 and 5: Dear Customer:Congratulations! We a
- Page 8 and 9: Table of Contents . . . continued7.
- Page 10 and 11: User InterfaceThis information will
- Page 12 and 13: What To Do First . . . continuedApp
- Page 14 and 15: Packaging Illustration1-2
- Page 16 and 17: 1.3 Installing the Battery PackThe
- Page 18 and 19: 1.5 Charging the Battery Pack‘‘
- Page 20 and 21: 1.6 Menu Page SelectionThe main men
- Page 22 and 23: SECTION 2INSTRUMENT POSITIONING &ME
- Page 24: Instrument Positioning & Measuremen
- Page 27 and 28: Positioning the Instrument on the W
- Page 29 and 30: 3.3 Calibration ProcedureTo perform
- Page 31 and 32: Calibration Procedure . . . continu
- Page 33 and 34: 4.2 Illuminant/Observer SelectionTh
- Page 35 and 36: Reference Entry . . . continued5) M
- Page 37 and 38: Sample Measurement . . . continued4
- Page 39 and 40: Using Measurement Averaging . . . c
- Page 41 and 42: Adjusting Tolerance Values . . . co
- Page 43 and 44: Adjusting Tolerance Values . . . co
- Page 45 and 46: 5.2 Pass/Fail MeasurementThe Pass/F
- Page 47 and 48: SECTION 6STORAGE OPERATIONSubjects
- Page 49 and 50: Storing Measurements . . . continue
- Page 51: Deleting Stored Measurements . . .
- Page 55 and 56: Printing Stored Measurements . . .
- Page 57 and 58: Tagging and Storing Operation . . .
- Page 59 and 60: Tagging and Storing Operation . . .
- Page 61 and 62: 6.5 QA-Master ‘‘Run Job’’ O
- Page 63 and 64: Setting RS-232 Communication Option
- Page 65 and 66: 7.2 Setting Operation OptionsThere
- Page 67 and 68: Setting Operation Options . . . con
- Page 69 and 70: Setting Operation Options . . . con
- Page 71 and 72: Setting Printout Options . . . cont
- Page 73 and 74: 7.4 Setting Date And TimeThe date a
- Page 75 and 76: 8.2 Cleaning the OpticsThe optics s
- Page 77 and 78: 8.4 Replacing the Target Window☛
- Page 79 and 80: 8.6 Troubleshooting TipsInstrument
- Page 81 and 82: 9.2 Scanning a Bar CodeFollow these
- Page 83 and 84: Troubleshooting . . . continuedWas
- Page 85 and 86: Technical Specifications . . . cont
- Page 87 and 88: Display Messages . . . continuedCal
- Page 89 and 90: APPENDIX - DCOLOR CHECKThe color ch
- Page 91 and 92: COLOR CHECK RECORDDate: Illuminant:
Deleting Stored Measurements . . . continuedDelete All3) Press [all] key #2.SELECTDELETE MODEexit all group lastKey#1 Key#2 Key#3 Key#44) Press [yes] key #4 to clear allstored data in all groups.DELETE EVERYTHING?noyesKey#1 Key#2 Key#3 Key#4- ‘‘ALL DATA CLEARED’’ isdisplayed.ALL DATA CLEARED5) ‘‘RESET GROUPS TODEFAULTS?’’ is displayed.- Press [no] key #1 to keep presetgroup names (i.e., names set inQA-Master). Press [yes] key #4 toreset names to factory defaults(i.e., Data Group 1, etc.).6) Press [exit] key #1 to exit deletemode.noRESET GROUPSTO DEFAULTS ?yesKey#1 Key#2 Key#3 Key#4exitALL GROUPSSET TO DEFAULTSSELECTDELETE MODEallgrouplastKey#1 Key#2 Key#3 Key#4Press6-6