SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite SP88/SP98 Spectrophotometer Operating Manual ... - X-Rite
4.4 Sample MeasurementMeasurement data can be displayed as absolute or difference for theselected sphere geometry (included or excluded). The SP88/SP98 uses‘‘INCLUDED’’ as the factory default. Refer to Operation Options, Section7.2 to change sphere geometry if required.When the SP88/SP98 is interfaced to a serial printer, data will printafter each measurement. The data that is printed is based on the PrintoutOptions selected (see Section 7.3).If measurement data storage is required, refer to Section 6.To take a sample measurement:1) If taking a difference measurement, make sure a reference is enteredinto the instrument (refer to Section 4.3 Reference Entry).2) Select color space by pressing ‘‘Key#2.’’ Select illuminant/observer bypressing ‘‘Key #3.’’L* 95.75 INCLUDEDa* -.53b* +1.16menu L*a*b* D65 10 difKey#1 Key#2 Key#3 Key#43) Position target window oversample.Sample4-5➩
Sample Measurement . . . continued4) Lower unit to target window andhold compressed.- Release unit from sample after‘‘READING COMPLETE’’ isdisplayed.☛ If an error message occurs during themeasurement, try reading sample again. If errormessage still occurs, refer to Display Messagesin Appendix B.5) The instrument will display theabsolute or difference measured.- The sample data can be viewedunder different illuminant/observercombinations by pressing ‘‘Key #3.’’The data can also be viewed in adifferent color space by pressing‘‘Key #2.’’☛ If auto reference is ‘‘on’’, the instrument will selectthe reference that is the closest match to thesample.L* 95.74 INCLUDEDa* -.52b* +1.14menu L*a*b* D65 10 difKey#1 Key#2 Key#3 Key#4L* 95.76 INCLUDEDa* -.18b* +1.00menu L*a*b* A 10 difKey#1 Key#2 Key#3 Key#4L* -.02 INCLUDEDa* .00b* -.01 E .02menu L*a*b* D65 10 ref01Key#1 Key#2 Key#3 Key#4- ∆L*a*b*, ∆L*C*h* and ∆Ecmccan display measurementdifferences as ‘‘words’’ if desired.Refer to Section 7.2 forinformation on Delta Expression.L* darker INCLUDEDa* >>grnb* >>yel E .02menu L*a*b* D65 10 ref01Key#1 Key#2 Key#3 Key#44-6
- Page 2 and 3: WARNING: Shielded interface cables
- Page 4 and 5: Dear Customer:Congratulations! We a
- Page 8 and 9: Table of Contents . . . continued7.
- Page 10 and 11: User InterfaceThis information will
- Page 12 and 13: What To Do First . . . continuedApp
- Page 14 and 15: Packaging Illustration1-2
- Page 16 and 17: 1.3 Installing the Battery PackThe
- Page 18 and 19: 1.5 Charging the Battery Pack‘‘
- Page 20 and 21: 1.6 Menu Page SelectionThe main men
- Page 22 and 23: SECTION 2INSTRUMENT POSITIONING &ME
- Page 24: Instrument Positioning & Measuremen
- Page 27 and 28: Positioning the Instrument on the W
- Page 29 and 30: 3.3 Calibration ProcedureTo perform
- Page 31 and 32: Calibration Procedure . . . continu
- Page 33 and 34: 4.2 Illuminant/Observer SelectionTh
- Page 35: Reference Entry . . . continued5) M
- Page 39 and 40: Using Measurement Averaging . . . c
- Page 41 and 42: Adjusting Tolerance Values . . . co
- Page 43 and 44: Adjusting Tolerance Values . . . co
- Page 45 and 46: 5.2 Pass/Fail MeasurementThe Pass/F
- Page 47 and 48: SECTION 6STORAGE OPERATIONSubjects
- Page 49 and 50: Storing Measurements . . . continue
- Page 51 and 52: Deleting Stored Measurements . . .
- Page 53 and 54: 6.3 Printing Stored MeasurementsThe
- Page 55 and 56: Printing Stored Measurements . . .
- Page 57 and 58: Tagging and Storing Operation . . .
- Page 59 and 60: Tagging and Storing Operation . . .
- Page 61 and 62: 6.5 QA-Master ‘‘Run Job’’ O
- Page 63 and 64: Setting RS-232 Communication Option
- Page 65 and 66: 7.2 Setting Operation OptionsThere
- Page 67 and 68: Setting Operation Options . . . con
- Page 69 and 70: Setting Operation Options . . . con
- Page 71 and 72: Setting Printout Options . . . cont
- Page 73 and 74: 7.4 Setting Date And TimeThe date a
- Page 75 and 76: 8.2 Cleaning the OpticsThe optics s
- Page 77 and 78: 8.4 Replacing the Target Window☛
- Page 79 and 80: 8.6 Troubleshooting TipsInstrument
- Page 81 and 82: 9.2 Scanning a Bar CodeFollow these
- Page 83 and 84: Troubleshooting . . . continuedWas
- Page 85 and 86: Technical Specifications . . . cont
Sample Measurement . . . continued4) Lower unit to target window andhold compressed.- Release unit from sample after‘‘READING COMPLETE’’ isdisplayed.☛ If an error message occurs during themeasurement, try reading sample again. If errormessage still occurs, refer to Display Messagesin Appendix B.5) The instrument will display theabsolute or difference measured.- The sample data can be viewedunder different illuminant/observercombinations by pressing ‘‘Key #3.’’The data can also be viewed in adifferent color space by pressing‘‘Key #2.’’☛ If auto reference is ‘‘on’’, the instrument will selectthe reference that is the closest match to thesample.L* 95.74 INCLUDEDa* -.52b* +1.14menu L*a*b* D65 10 difKey#1 Key#2 Key#3 Key#4L* 95.76 INCLUDEDa* -.18b* +1.00menu L*a*b* A 10 difKey#1 Key#2 Key#3 Key#4L* -.02 INCLUDEDa* .00b* -.01 E .02menu L*a*b* D65 10 ref01Key#1 Key#2 Key#3 Key#4- ∆L*a*b*, ∆L*C*h* and ∆Ecmccan display measurementdifferences as ‘‘words’’ if desired.Refer to Section 7.2 forinformation on Delta Expression.L* darker INCLUDEDa* >>grnb* >>yel E .02menu L*a*b* D65 10 ref01Key#1 Key#2 Key#3 Key#44-6