SECTION 4NORMAL OPERATIONSubjects covered in Section 4 are:4.1 Color Space Selection4.2 Illuminant/Observer Selection4.3 Reference Entry4.4 Sample Measurement4.5 Using Measurement Averaging4.1 Color Space SelectionThere are eight colorimetric systems (absolute and difference) that canbe selected when displaying measurement data. Each momentarydepression of ‘‘Key #2’’ will page through: L*a*b*, L*C*h°, XYZ, Lab(Hunter), Wht, Yel, Yxy and ∆E CMC ). Pressing [dif] key #4 will displaythe difference values for the selected color space.☛ The instrument is shippedfrom the factory with XYZ,Hunter Lab, Wht, Yel andYxy disabled. Refer toSection 7.2, OperationOptions to enable or disablecolor spaces.Yellowness will only allowilluminant/observercombination C 2 .L* 95.73 INCLUDEDa* -.60b* +1.26menu L*a*b* D65 10 difKey#1 Key#2 Key#3 Key#4L* -.09a* -.27b* +.60menu L*a*b*INCLUDEDE .66D65 10 ref01Key#1 Key#2 Key#3 Key#4To select a color space:- Repeatedly press‘‘Key #2.’’L* 95.73 INCLUDEDC* 1.40h 115.47menu L*C*h D65 10 difKey#1 Key#2 Key#3 Key#4L* -.09 INCLUDEDC* -.09H* +.01 E .66menu L*C*H* D65 10 ref01Key#1 Key#2 Key#3 Key#4XYZLab (Hunter)WhtYelYxyEcmc4-1
4.2 Illuminant/Observer SelectionThe SP88/SP98 has eighteen illuminant/observer combinationsavailable. Any combination can be selected after a measurement to viewdata under different conditions.To select an illuminant/observer:- Repeatedly press ‘‘Key #3.’’L* 97.98 INCLUDEDa* -.77b* -7.24menu L*a*b* C 2 difKey#1 Key#2 Key#3 Key#4L* 98.34 INCLUDEDa* -2.83b* -6.42menu L*a*b* C 10 difKey#1 Key#2 Key#3 Key#4☛ All illuminant/observer combinations may notdisplay. Certain combinations may beturned off in Operation Options, Section 7.2.D65 10 , A 10 , and F2 10 are preset on at thefactory.2D65 (Daylight 6500k)10D652D50Daylight 5000k)10D502A (Incandescent)10A2F2 (Cool White)10F2F7 2(Broad Band)10F72 F11 (TL84)10 F11F12 2UltralumeF12 102D75 (Daylight 7500k)10D754-2
- Page 2 and 3: WARNING: Shielded interface cables
- Page 4 and 5: Dear Customer:Congratulations! We a
- Page 8 and 9: Table of Contents . . . continued7.
- Page 10 and 11: User InterfaceThis information will
- Page 12 and 13: What To Do First . . . continuedApp
- Page 14 and 15: Packaging Illustration1-2
- Page 16 and 17: 1.3 Installing the Battery PackThe
- Page 18 and 19: 1.5 Charging the Battery Pack‘‘
- Page 20 and 21: 1.6 Menu Page SelectionThe main men
- Page 22 and 23: SECTION 2INSTRUMENT POSITIONING &ME
- Page 24: Instrument Positioning & Measuremen
- Page 27 and 28: Positioning the Instrument on the W
- Page 29 and 30: 3.3 Calibration ProcedureTo perform
- Page 31: Calibration Procedure . . . continu
- Page 35 and 36: Reference Entry . . . continued5) M
- Page 37 and 38: Sample Measurement . . . continued4
- Page 39 and 40: Using Measurement Averaging . . . c
- Page 41 and 42: Adjusting Tolerance Values . . . co
- Page 43 and 44: Adjusting Tolerance Values . . . co
- Page 45 and 46: 5.2 Pass/Fail MeasurementThe Pass/F
- Page 47 and 48: SECTION 6STORAGE OPERATIONSubjects
- Page 49 and 50: Storing Measurements . . . continue
- Page 51 and 52: Deleting Stored Measurements . . .
- Page 53 and 54: 6.3 Printing Stored MeasurementsThe
- Page 55 and 56: Printing Stored Measurements . . .
- Page 57 and 58: Tagging and Storing Operation . . .
- Page 59 and 60: Tagging and Storing Operation . . .
- Page 61 and 62: 6.5 QA-Master ‘‘Run Job’’ O
- Page 63 and 64: Setting RS-232 Communication Option
- Page 65 and 66: 7.2 Setting Operation OptionsThere
- Page 67 and 68: Setting Operation Options . . . con
- Page 69 and 70: Setting Operation Options . . . con
- Page 71 and 72: Setting Printout Options . . . cont
- Page 73 and 74: 7.4 Setting Date And TimeThe date a
- Page 75 and 76: 8.2 Cleaning the OpticsThe optics s
- Page 77 and 78: 8.4 Replacing the Target Window☛
- Page 79 and 80: 8.6 Troubleshooting TipsInstrument
- Page 81 and 82: 9.2 Scanning a Bar CodeFollow these
4.2 Illuminant/Observer SelectionThe <strong>SP88</strong>/<strong>SP98</strong> has eighteen illuminant/observer combinationsavailable. Any combination can be selected after a measurement to viewdata under different conditions.To select an illuminant/observer:- Repeatedly press ‘‘Key #3.’’L* 97.98 INCLUDEDa* -.77b* -7.24menu L*a*b* C 2 difKey#1 Key#2 Key#3 Key#4L* 98.34 INCLUDEDa* -2.83b* -6.42menu L*a*b* C 10 difKey#1 Key#2 Key#3 Key#4☛ All illuminant/observer combinations may notdisplay. Certain combinations may beturned off in Operation Options, Section 7.2.D65 10 , A 10 , and F2 10 are preset on at thefactory.2D65 (Daylight 6500k)10D652D50Daylight 5000k)10D502A (Incandescent)10A2F2 (Cool White)10F2F7 2(Broad Band)10F72 F11 (TL84)10 F11F12 2UltralumeF12 102D75 (Daylight 7500k)10D754-2