B - Connection to <strong>the</strong> MV publicdistribution network1 Supply of power at mediumvoltageB13O21- Cycle 1SRI O1 fI o15 to 30 sI nSRO3fault0.3 s 0.4 sPermanent fault2 - Cycle 2SRa - Fault on ma<strong>in</strong> feederI O1fO2SR1O3SR2O4I nI o0.3 s 0.4 s15 to 30s15 to 30 sfault0.4 sPermanent fault0.45 sb - Fault on section supplied through Automatic L<strong>in</strong>e SwitchI fO1O2SR1 O3I n15 to 30 s15 to 30 sSR2I oFault0.3 s 0.4 s0.4 sOpen<strong>in</strong>g of ALSFig. B14 : Automatic reclos<strong>in</strong>g cycles of a circuit-breaker controll<strong>in</strong>g a radial MV feederUnderground cable networksFaults on underground cable networks are sometimes <strong>the</strong> result of carelessworkmanship by cable jo<strong>in</strong>ters or by cable lay<strong>in</strong>g contractors, etc., but are morecommonly due to damage from tools such as pick-axes, pneumatic drills and trenchexcavat<strong>in</strong>g mach<strong>in</strong>es, and so on, used by o<strong>the</strong>r utilities.Insulation failures sometimes occur <strong>in</strong> cable term<strong>in</strong>at<strong>in</strong>g boxes due to overvoltage,particularly at po<strong>in</strong>ts <strong>in</strong> a MV system where an overhead l<strong>in</strong>e is connected to anunderground cable. The overvoltage <strong>in</strong> such a case is generally of atmosphericorig<strong>in</strong>, and electromagnetic-wave reflection effects at <strong>the</strong> jo<strong>in</strong>t box (where <strong>the</strong> naturalimpedance of <strong>the</strong> circuit changes abruptly) can result <strong>in</strong> overstress<strong>in</strong>g of <strong>the</strong> cablebox<strong>in</strong>sulation to <strong>the</strong> po<strong>in</strong>t of failure. Overvoltage protection devices, such as lightn<strong>in</strong>garresters, are frequently <strong>in</strong>stalled at <strong>the</strong>se locations.Faults occurr<strong>in</strong>g <strong>in</strong> cable networks are less frequent than those on overhead (O/H)l<strong>in</strong>e systems, but are almost <strong>in</strong>variably permanent faults, which require more time forlocalization and repair than those on O/H l<strong>in</strong>es.Where a cable fault occurs on a r<strong>in</strong>g, supply can be quickly restored to all consumerswhen <strong>the</strong> faulty section of cable has been determ<strong>in</strong>ed.If, however, <strong>the</strong> fault occurs on a radial feeder, <strong>the</strong> delay <strong>in</strong> locat<strong>in</strong>g <strong>the</strong> fault andcarry<strong>in</strong>g out repair work can amount to several hours, and will affect all consumersdownstream of <strong>the</strong> fault position. In any case, if supply cont<strong>in</strong>uity is essential on all,or part of, an <strong>in</strong>stallation, a standby source must be provided.Centralized remote control, based on SCADA(Supervisory Control And Data Acquisition)systems and recent developments <strong>in</strong> IT(Information Technology) techniques, isbecom<strong>in</strong>g more and more common <strong>in</strong> countries<strong>in</strong> which <strong>the</strong> complexity of highly <strong>in</strong>terconnectedsystems justifies <strong>the</strong> expenditure.Remote control of MV networksRemote control on MV feeders is useful to reduce outage durations <strong>in</strong> case of cablefault by provid<strong>in</strong>g an efficient and fast mean for loop configuration. This is achievedby motor operated switches implemented <strong>in</strong> some of <strong>the</strong> substations along <strong>the</strong> loopassociated with relevant remote telecontrol units. Remote controled substation willalways be reenergized through telecontroled operation when <strong>the</strong> o<strong>the</strong>r ones couldhave to wait for fur<strong>the</strong>r manual operation.© Schneider Electric - all rights reservedSchneider Electric - <strong>Electrical</strong> <strong>in</strong>stallation guide <strong>2009</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!