Electrical Installation Guide 2009 - the global specialist in energy ...

Electrical Installation Guide 2009 - the global specialist in energy ...

Electrical Installation Guide 2009 - the global specialist in energy ...

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

A - General rules of electrical <strong>in</strong>stallation design4 Power load<strong>in</strong>g of an <strong>in</strong>stallationA19Level 1 Level 2 Level 3UtilizationApparent Utilization Apparent Simultaneity Apparent Simultaneity Apparent Simultaneity Apparentpower factor power factor power factor power factor power(Pa) max. demand demand demand demandkVA max. kVA kVA kVA kVAWorkshop A La<strong>the</strong> no. 1 5 0.8no. 2no. 3no. 4no. 1no. 25 socketoutlets10/16 A30 fluorescentlamps55522180.80.80.80.80.81Distributionbox3 1 3144441.61.6180.750.214.43.63PowercircuitPedestaldrillSocketouletsLight<strong>in</strong>gcircuitWorkshop Adistributionbox0.918.9Ma<strong>in</strong>generaldistributionboardMGDBWorkshop B Compressor3 socketoutlets10/16 A10 fluorescentlampsWorkshop C Ventilation no. 1Ovenno. 2no. 1no. 25 socketoutlets10/16 A20 fluorescentlamps1510.612.52.515151820.8111111111210.612.52.5151518210.41Distributionbox10.28113552Light<strong>in</strong>gcircuitPowvercircuitPowercircuit12 Workshop BSocketouletsdistribution4.3 boxSocketouletsLight<strong>in</strong>gcircuit0.9Workshop Cdistributionbox0.915.637.80.965LV / MVFig A14 : An example <strong>in</strong> estimat<strong>in</strong>g <strong>the</strong> maximum predicted load<strong>in</strong>g of an <strong>in</strong>stallation (<strong>the</strong> factor values used are for demonstration purposes only)4.6 Choice of transformer rat<strong>in</strong>gWhen an <strong>in</strong>stallation is to be supplied directly from a MV/LV transformer and<strong>the</strong> maximum apparent-power load<strong>in</strong>g of <strong>the</strong> <strong>in</strong>stallation has been determ<strong>in</strong>ed, asuitable rat<strong>in</strong>g for <strong>the</strong> transformer can be decided, tak<strong>in</strong>g <strong>in</strong>to account <strong>the</strong> follow<strong>in</strong>gconsiderations (see Fig. A15):b The possibility of improv<strong>in</strong>g <strong>the</strong> power factor of <strong>the</strong> <strong>in</strong>stallation (see chapter L)b Anticipated extensions to <strong>the</strong> <strong>in</strong>stallationb <strong>Installation</strong> constra<strong>in</strong>ts (e.g. temperature)b Standard transformer rat<strong>in</strong>gsApparent power In (A)kVA 237 V 410 V100 244 141160 390 225250 609 352315 767 444400 974 563500 1218 704630 1535 887800 1949 11271000 2436 14081250 3045 17601600 3898 22532000 4872 28162500 6090 35203150 7673 4436Fig. A15 : Standard apparent powers for MV/LV transformers and related nom<strong>in</strong>al output currents© Schneider Electric - all rights reservedSchneider Electric - <strong>Electrical</strong> <strong>in</strong>stallation guide <strong>2009</strong>

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!