<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications ManualModular control system for<strong>Buderus</strong> EMS boilers with room,zone, low loss header, and solarcontrol capability


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual2 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manualTable of Contents<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual1 System description 52 GB142 with unmixed heating zone - piping diagram 63 GB142 with unmixed heating zone - wiring diagram 74 GB142 with 1 unmixed zone, 1 mixed zone and DHW - piping diagram 85 GB142 with 1 unmixed zone, 1 mixed zone and DHW - wiring diagram 96 GB142 with 2 mixed zones, 1 unmixed zone and DHW - piping diagram 107 GB142 with 2 mixed zones, 1 unmixed zone and DHW - wiring diagram 118 GB142 with 1 unmixed zone and solar DHW - piping diagram 129 GB142 with 1 unmixed zone and solar DHW - wiring diagram 1310 GB142 with 1 unmixed zone, 1 mixed zone and solar DHW - piping diagram 1411 GB142 with 1 unmixed zone, 1 mixed zone and solar DHW - wiring diagram 15<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 3


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual4 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual1 System Description<strong>Room</strong> controller for <strong>Buderus</strong> EMS boilersFeatures:• <strong>Room</strong> reset• Outdoor reset• <strong>Room</strong>, zone, low loss header and solarcontrol capability• Graphic display and user interface• System diagnosis• Error code display• Programmable thermostat.• User level• Service level• Mounted in boiler• <strong>Room</strong> sensor• DHW priority.• 4 independent heating zones3 available modules for added functionality:MM10 WM10 SM10Description Mixing module Low loss header module Solar DHW moduleInput 1 temperature sensor FV low loss header sensor FK collector sensor FSKInput 2 N/A N/A bottom tank sensorFSSOutput 1 pump PH pump PH solar pump PSSOutput 2 120V mixing valve SH N/A N/ANotesMax. 3 MM10 per system:Future expandability withprogrammable room sensorRC20Max. 1 WM10 per system Max. 1 SM10 persystem;Pump modulates 30 -100% for best delta T.| 5<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual2 GB142 with unmixed heating zone - piping diagramP2CHECK VALVEPSPK6 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual3 GB142 with unmixed heating zone - wiring diagramLegendRC 35 roomcontrol unitEXTPumpTTempSensorServiceSwitchlow voltage120 VAC5 amp maxRC FA WA FW EVPK PSPWF Netz61 63 24 25 13 14TOutdoorTempSensorTTankSensorDHWpumpBoilerpumpHeating Circmixing stationP3120 VACServiceHigh TempHeating Circuit<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 7


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual4 GB142 with 1 unmixed zone, 1 mixed zone and DHW - piping diagramP1 P2CHECK VALVEPSPK8 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual5 GB142 with 1 unmixed zone, 1 mixed zone and DHW - wiring diagramLegendPumpMM10Heating Circmixing stationTMixSensorMotorRC 35 roomcontrol unitEXTTTempSensorServiceSwitchHigh TempHeating Circuitlow voltage120 VAC5 amp maxRC FA WA FW EVPK PSPWF Netz61 63 24 25 13 14TOutdoorTempSensorTTankSensorDHWpumpBoilerpump120 VACServiceSwitch<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 9


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual6 GB142 with 2 mixed zones, 1 unmixed zone and DHW - piping diagramP1 P2 P3CHECK VALVEPSPK10 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual7 GB142 with 2 mixed zones, 1 unmixed zone and DHW - wiring diagramLegendMM10Heating Circmixing stationP1TMixSensorPumpMotorTTempSensorMM10Heating Circmixing stationP2TMixSensorServiceSwitchRC 35 roomcontrol unitEXTHigh TempHeating Circuitlow voltage120 VAC5 amp maxRC FA WA FW EVPK PSPWF Netz61 63 24 25 13 14TOutdoorTempSensorTTankSensorDHWpumpBoilerpumpHeating Circmixing stationP3120 VACServiceSwitch<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 11


8 GB142 with 1 unmixed zone and solar DHW - piping diagram<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications ManualP2CHECK VALVEPSPK12 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual9 GB142 with 1 unmixed zone and solar DHW - wiring diagramLegendPumpSM10TCollectorTempSensorSolarpumpMotorTDHWTankSensorTTempSensorServiceSwitchlow voltageRC FA WA FW EVRC 35 roomcontrol unitEXTTTankSensorHigh TempHeating Circuit120 VAC5 amp maxPK PSPWF Netz61 63 24 25 13 14DHWpumpBoilerpump120 VACServiceSwitch<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 13


<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual10 GB142 with 1 unmixed zone, 1 mixed zone and solar DHW - piping diagramP1 P2CHECK VALVEPSPK14 |Technical specifi cations are subject to change without prior notice<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009


Applications manual<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong>Applications Manual11 GB142 with 1 unmixed zone, 1 mixed zone and solar DHW - wiring diagramLegendMM10Heating Circmixing stationTMixSensorPumpRC 35 roomcontrol unitEXTMotorTTempSensorSM10TCollectorTempSensorSolarpumpTDHWTankSensorServiceSwitchHigh TempHeating Circuitlow voltage120 VAC5 amp maxRC FA WA FW EVPK PSPWF Netz61 63 24 25 13 14TTankSensorDHWpumpBoilerpump120 VACServiceSwitch<strong>RC35</strong> <strong>Room</strong> <strong>Controller</strong> applications manual | 01.2009Technical specifi cations are subject to change without prior notice| 15


Bosch Thermotechnology Corp.50 Wentworth AvenueLondonderry, NH 03053Tel: 1-800-BUDERUSFax: 1-603-584-1681www.buderus.netBTC 462001101 A | 01.2009

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!