PRESSURE SWITCHAir pressure switch works on negative pressure. Whenblower comes on air pressure switch operates intermittentpilot and gas valve. Air pressure switch is factory set andwill only work when blower operates properly. It will notallow boiler to come on if blower does not generate enoughpressure or if venting system is blocked.Factory Pressure Switch Set point:-0.4” wc. for 2-5 section boilers.-0.5” w.c. for 6-7 section boilers.EQUIPMENT & OPTIONAL ACCESSORIESRollout Switch(FLAME ROLLOUT SAFETY SHUTOFF)Rollout switch is temperature-sensitive fuse link device.Located on boiler base just outside fire box. In event ofheat exchanger flueway blockage causing flame to rollout of fire box, fuse does not change in appearance whenblown.If rollout switch blows, it must be replaced with exactreplacement. Check heat exchanger flueways for blockagewhen restoring system to operating condition. DO NOToperate system without rollout switch.31