Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesStationary wet sump installationSTC 80/100, STS 80/100, TP 80/1005Wilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesChain (Item 6)Made of stainless steel, including shackles,length: 5 m and 10 m, lifting capacity: 400kg43267Q*RSCheck valve body (Item 2)Made of cast iron 25, (EN-GJL-250), with unrestrictedpassage, incl. cleaning port and ventilationdevice, installation accessories, flanges PN 10/16,to DIN 2501, with(*) or without draw. No.(draw. No. 53.4-309)DN 80/100/150DN 80 DN 100 DN 150Q 240 270 335R 245 282 397S 260 300 4001TUGate valve (Item 3)Made of cast iron 25, (EN-GJL-250) installationaccessories, flanges PN 10/16 to DIN 2501,DN 80/100/150DN 80 DN 100 DN 150T 295 325 425U 80 190 210TP 150543VWPipe bend (Item 4)Made of nodular graphite iron (EN-GJS-400-15),with 2 flanges, installation accessories for a flangeconnection, flanges PN 10/16, DIN 28637,DN 80/100/150DN 80 DN 100 DN 150V 165 180 220W 165 180 22026XYZY-piece (Item 8)Made of galvanised steel 37, with 2 sets of installationaccessories, flanges PN 10/16, DIN 2501,DN 80/80/80, 100/100/100 or150/150/150DN 80 DN 100 DN 150X 615 615 920Y 168 208 287Z 167 207 2871Ø 5260STS/TP 80/100 pipe joint (Item 7)Made of galvanised steel, fits 2" guide pipe,required for guide pipes longer than 6 m130Installation accessories (Item 5)For a flange connection with 8 screws and nuts and1 flat seal, for flanges PN 10/16, DIN 250192 As of: 06/2004 - Subject to change without prior notice
ISewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesPortable wet sump installationSTS 80/100, TP 80/10015146Ø 1954903080300590359130Ø 22090337,5TP 80/100 ground support foot (Item 9)Made of stainless steel, consists of 3 support feet,1 base plate and mounting hardwareSTS 80 (Item 9a)STS 100 (Item 9b)Consists of 3 support feet, 1 base plate andmounting hardwareSubmersible pumps13230,5380,5Item 9a260428Item 9b1030125TP 150 ground support foot (Item 9)Made of stainless steel, consists of 3 supportfeet, 1 base plate and mounting hardware9441For STC 80/100see dimension drawing of pumpTP 150560Chain (Item 6)Made of stainless steel, including shackles,length: 5 m and 10 m, lifting capacity: 400kg6BACPipe bend (Item 10)Made of stainless steel, can be used for direct hoseconnection or mounting a Storz fixed coupling.Variable set-up possible with 45° hole pitch (TP100/150)DN 80 DN 100 DN 150A G 3 G 4 Ø 148B 240 280 432.5C Ø 89 – –15109FEDGStorz fixed coupling for mounting to pipebend (Item 13)AL, with R3 or R4 female thread for connectionnominal diameter 80/100DN 80 DN 100D 40 48E Ø 78 Ø 100F 105 133G R 3 R 4JHKStorz hose coupling (Item 14)Made of aluminium, for hose inner dia. 90/110 mmDN 80 DN 100H 140 170I 105 133J Ø 80 Ø 100K Ø 90 Ø 110can be wound upPressure hose for direct hose connection(Item 15)Material: Synthetic material PN 8 including 2 hoseclips, hose inner diameter 90/110/150 mm, length10, 20 and 30 mAs of: 06/2004 - Subject to change without prior notice93
- Page 1 and 2:
ContentsProduct Overview and Fields
- Page 3 and 4:
Product Overview and Fields of Appl
- Page 5 and 6:
General Notes and AbbreviationsWear
- Page 7 and 8:
ContentsSubmersible pumpsSewage/Fae
- Page 9 and 10:
Sewage DisposalPlanning GuideWastew
- Page 11 and 12:
Submersible PumpsProduct Advantages
- Page 13 and 14:
Submersible PumpsProduct Advantages
- Page 15 and 16:
Submersible PumpsProduct Advantages
- Page 17 and 18:
Wastewater/DrainageWilo-Drain TM/TM
- Page 19 and 20:
Wastewater/DrainageWilo-Drain TM/TM
- Page 21 and 22:
Wastewater/DrainageWilo-Drain TM/TM
- Page 23 and 24:
Wastewater/DrainageWilo-Drain TM/TM
- Page 25 and 26:
Wastewater/DrainageWilo-Drain TS 40
- Page 27 and 28:
Wastewater/DrainageWilo-Drain TS 40
- Page 29 and 30:
Wastewater/DrainageWilo-Drain CP 32
- Page 31 and 32:
Wastewater/DrainageWilo-Drain LP 40
- Page 33 and 34:
Wastewater/DrainageWilo-Drain LP 40
- Page 35 and 36:
Wastewater/DrainageWilo-Drain TC 40
- Page 37 and 38:
Wastewater/DrainageWilo-Drain TC 40
- Page 39 and 40: Wastewater/DrainageWilo-Drain TC 40
- Page 41 and 42: Wastewater/DrainageWilo-Drain TP 50
- Page 43 and 44: Wastewater/DrainageWilo-Drain TP 50
- Page 45 and 46: Wastewater/DrainageWilo-Drain TP 50
- Page 47 and 48: Hot WaterWilo-Drain TMT/TMC, VCPump
- Page 49 and 50: Hot WaterWilo-Drain TMT/TMCPump Cur
- Page 51 and 52: Sewage/FaecesWilo-Drain TP 40 S/25,
- Page 53 and 54: Sewage/FaecesWilo-Drain TP 40 S/25,
- Page 55 and 56: Sewage/FaecesWilo-Drain TP 40 SPump
- Page 57 and 58: Sewage/FaecesWilo-Drain TP 40 S/25,
- Page 59 and 60: Sewage/FaecesWilo-Drain STC 80/100,
- Page 61 and 62: Sewage/FaecesWilo-Drain STC 80/100,
- Page 63 and 64: Sewage/FaecesWilo-Drain STC 80/100,
- Page 65 and 66: Sewage/FaecesWilo-Drain STC 80/100,
- Page 67 and 68: Sewage/FaecesWilo-Drain STC 80/100,
- Page 69 and 70: Sewage/FaecesWilo-Drain STC 80/100,
- Page 71 and 72: Sewage/FaecesWilo-Drain STC 80/100,
- Page 73 and 74: Sewage/FaecesWilo-Drain STC 80/100P
- Page 75 and 76: ISewage/FaecesWilo-Drain STC 80/100
- Page 77 and 78: Sewage/FaecesWilo-Drain STS 80/100P
- Page 79 and 80: ISewage/FaecesWilo-Drain STS 80/100
- Page 81 and 82: Sewage/FaecesWilo-Drain TP 80, TP 1
- Page 83 and 84: Sewage/FaecesWilo-Drain TP 80, TP 1
- Page 85 and 86: Sewage/FaecesWilo-Drain TP 80, TP 1
- Page 87 and 88: ISewage/FaecesWilo-Drain TP 80, TP
- Page 89: ISewage/FaecesWilo-Drain STC 80/100
- Page 93 and 94: Sewage/FaecesWilo-Drain Electrical
- Page 95 and 96: Sewage/FaecesWilo-Drain Electrical
- Page 97 and 98: Sewage/FaecesWilo-Drain Electrical
- Page 99 and 100: Sewage/FaecesSubmersible pumpsAs of
- Page 101 and 102: ContentsLifting plants/Wet sump pum
- Page 103 and 104: Lifting PlantsProduct AdvantagesWil
- Page 105 and 106: Lifting PlantsProduct AdvantagesWil
- Page 107 and 108: Condensate/Wastewater/Drainage Wate
- Page 109 and 110: Condensate/Wastewater/Drainage Wate
- Page 111 and 112: Condensate/Wastewater/Drainage Wate
- Page 113 and 114: Condensate/Wastewater/Drainage Wate
- Page 115 and 116: Condensate/Wastewater/Drainage Wate
- Page 117 and 118: Condensate/Wastewater/Drainage Wate
- Page 119 and 120: Sewage/FaecesWilo-DrainLift KHProdu
- Page 121 and 122: Sewage/FaecesWilo-DrainLift KHTechn
- Page 123 and 124: Sewage/FaecesWilo-DrainLift S, M, L
- Page 125 and 126: Sewage/FaecesWilo-DrainLift S, M, L
- Page 127 and 128: Sewage/FaecesWilo-DrainLift S, M, L
- Page 129 and 130: Sewage/FaecesWilo-DrainLift SPump C
- Page 131 and 132: Sewage/FaecesWilo-DrainLift SMechan
- Page 133 and 134: Sewage/FaecesWilo-DrainLift MDimens
- Page 135 and 136: Sewage/FaecesWilo-DrainLift LDimens
- Page 137 and 138: Sewage/FaecesWilo-DrainLift LTypica
- Page 139 and 140: Sewage/FaecesWilo-DrainLift XLDimen
- Page 141 and 142:
Sewage/FaecesWilo-DrainLift S, M, L
- Page 143 and 144:
Sewage/FaecesWilo-DrainLift XXLDime
- Page 145 and 146:
Sewage/FaecesWilo-DrainLift XXLDime
- Page 147 and 148:
Wet Sump Pumping StationsProduct Ad
- Page 149 and 150:
Wet Sump Pumping StationsWilo-Drain
- Page 151 and 152:
Wet Sump Pumping StationsWilo-Drain
- Page 153 and 154:
Wet Sump Pumping StationsWilo-Drain
- Page 155 and 156:
Wet Sump Pumping StationsWilo-Drain
- Page 157 and 158:
Wet Sump Pumping StationsWilo-Drain
- Page 159 and 160:
NotesAs of: 06/2004 - Subject to ch
- Page 161 and 162:
NotesAs of: 06/2004 - Subject to ch
- Page 163 and 164:
NotesAs of: 06/2004 - Subject to ch
- Page 165 and 166:
NotesAs of: 06/2004 - Subject to ch
- Page 167 and 168:
NotesAs of: 06/2004 - Subject to ch
- Page 169 and 170:
NotesAs of: 06/2004 - Subject to ch
- Page 171 and 172:
NotesAs of: 06/2004 - Subject to ch
- Page 173:
NotesAs of: 06/2004 - Subject to ch