<strong>Contents</strong>Product Overview and Fields of Application . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 4General Notes and Abbreviations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6Submersible pumps . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8Lifting plants Submersible pumpsLifting plants . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 102Wet Sump Pumping Stations . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Wet Sump Pumping StationsSubject to change without prior notice3


Product Overview and Fields of ApplicationDrainage/Sewage DisposalSubmersible Motor PumpsPump typeCompl.freepassage[mm]MaceratorFloormountedUnderfloorMain field of applicationPageWastewater/Drainage 18Wilo-Drain TM/TMW 32 10 S C S 21Wilo-Drain TS 40 10 M/C C M 21Wilo-Drain TS 50 10 M/C C M 21Wilo-Drain TS 65 10 M/C C C 21Wilo-Drain TS 40/12, 40/16 10 M/C C M 21Wilo-Drain CP 5 to 10 S/M 21Wilo-Drain LP 40 10 S/M/C C 33Wilo-Drain TC 40 35 M/C M/C M/C 38Wilo-Drain TP 50 44 M/C M/C C M/C 38Wilo-Drain TP 65 44 M/C M/C C C 38Hot Water 48Wilo-Opti-Drain TMT/TMC 10 C C C 49Wilo-Drain VC 5 to 7 S/M/C C M/C 49Sewage/Faeces 53Wilo-Drain TP 40 S/25 10 • S/M G 54Wilo-Drain TP 40 S 10 • S/M C 54Wilo-Drain STC 80/100 50 to 80 M/C M/C M/C C 63Wilo-Drain STS 80/100 78 to 95 M/C M/C M/C C 64Wilo-Drain TP 80 80 M/C M/C M/C C M/C 65Wilo-Drain TP 100 80 to 95 M/C M/C M/C C M/C 65Wilo-Drain TP 150 > 100 C C C C C 65Product Overview and Fields of ApplicationDrainage/Sewage DisposalSubmersible Motor PumpsLegend:S: Single/two-family houseM: Multifamily houseC: Commercial• ApplicableFields of application:Wastewater/drainageWastewater/coarse contaminantsSewage/FaecesManufacturing sewageCondensate, condensing-boiler/air-conditioning equipment4 As of: 06/2004 - Subject to change without prior notice


Product Overview and Fields of ApplicationDrainage/Sewage DisposalLifting UnitsPump typeMaceratorDry-wellinstallationFloormountedUnderfloorMain field of applicationPageCondensate/Wastewater/Drainage 108Wilo-DrainLift Con • S/M/C 109Wilo-DrainLift TMP • S S 114Wilo-DrainLift Box • S/M S/M S/M 114Wilo-DrainLift FH • S/M/C S/M/C C S/M/C 114Wilo-DrainLift D-FH • S/M/C S/M/C C S/M/C 114Sewage/Faeces 121Wilo-DrainLift KH • • S S S 122Wilo-DrainLift S • S S S S 128Wilo-DrainLift M • S/M S/M S/M C S/M 128Wilo-DrainLift L • M/C M/C M/C C M/C 128Wilo-DrainLift XL • M/C M/C M/C C M/C 128Wilo-DrainLift XXL • C C C C C 128Wet Sump Pumping Stations 150Wilo-DrainLift WS • • S/M/C S/M/C S/M/C C C 150Wilo-DrainLift WB • • S/M/C S/M/C S/M/C C C 151Lifting UnitsLegend:S: Single/two-family houseM: Multifamily houseC: Commercial• ApplicableFields of application:Wastewater/drainageWastewater/coarse contaminantsSewage/FaecesManufacturing sewageCondensate, condensing-boiler/air-conditioning equipmentAs of: 06/2004 - Subject to change without prior notice5


General Notes and AbbreviationsAbbreviations used and what they meanAbbreviationMeaningAbbreviation MeaningControl input"0...10 V"Automatic adjustment of pump output during setback TOP-Controlphases, e.g. boiler setback operation overnightResistant to blocking current, no motor protectionTrinkwV 2001Three-phase motorVDI 2035Control mode for constant differential pressureCombined control mode of constant and variableWSKdifferential pressuresControl mode for differential-pressure control as afunction of media temperatureGeneral Notes and AbbreviationsControl mode for variable differential pressureControl mode for differential temperatureSingle-phase AC motorElectronically commutated motor with new damp-roomenclosure. Newly developed glandless drive concept forhigh-efficiency pumps.Control input "Overriding Off"Control input "Overriding Min", e.g. for setbackoperation without autopilotResidual-current deviceBuilding automationSpecial cast iron: white malleable cast ironDegree of German water hardness, unit for assessingwater hardnessDelivery headInterfaceIntegrated full motor protection, including triggeringelectronicsInfrared interfacePaintwork with high adhesive strength for long-lastingcorrosion protectionCapacitorThermal resistor sensorAuthorization for products with plastics, for use indrinking-water applicationsLocal operating network(open, non-manufacturer-dependent, standardizeddatabus system in LONWORKS networks)Motor module (drive motor + impeller + terminal box/electronics module) for exchange in the TOP .. SeriesPump master computer, Wilo-specific data busPlatinum temperature sensor with a resistance value of1,000 Ω at 0 °C.V1~ Single-phase alternating current3~ Three-phase alternating currentAutopilotrbcDM∆p-c∆p-cv∆p-T∆p-v∆TEMECM technologyExt. OffExt. MinRCDBAGTW°dHIFIntegr.IRCataphoresiscoatingCapTRSKTWLONMOTPLRPt 1000Q (= ) Delivery rateSBMSSMProcess signal or collective run signalCollective fault signalAnalog input for external activation of functionsBuilding-automation management with pumps andaccessoriesGerman drinking-water ordinance from 2001(valid from 01.01.2003)VDI guideline for preventing damage in hot-waterheating installationsThermal winding contacts (in motor for monitoringwinding temperature, full motor protection by additionaltripping unit)6 As of: 06/2004 - Subject to change without prior notice


General Notes and AbbreviationsWearPumps or parts of pumps are subject to wear in accordance withstate-of-the-art technology (DIN 31051/DIN-EN 13306). This wearmay vary depending on operating parameters (temperature,pressure, water condition) and the installation/usage situation andmay result in the malfunction or failure at different times of theabove-mentioned products/components including their electrical/electronic circuitry.Wear parts are all components subject to rotatory or dynamic strainincluding electronic components under tension, in particular:– seals / gaskets (incl. mechanical seals), seal washers– bearings and shafts– stuffing boxes– capacitors– relays / contactors / switches– electronic circuits, semiconductor components, etc.– impellers– wearing rings / wearing platesWILO – General terms of delivery and serviceThe latest version of our General Terms of Delivery and Service canbe found on the Internet atwww.wilo.com or www.wilo.deWe do not accept liability for faults or defects arising from naturalwear and tear.As of: 06/2004 - Subject to change without prior notice7


<strong>Contents</strong>Submersible pumpsPlanning Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10Submersible PumpsProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12Product Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13Wastewater/Drainage . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Wilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 21Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 22Wilo-Drain TM/TMW . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 26Pump Curves, Dimension Drawings, Dimensions, Weights, Accessories . . . . . . . . . . . . . . . . . . . 26Wilo-Drain TS 40, TS 50, TS 65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Pump Curves, Terminal Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 27Dimension Drawing, Dimensions, Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 28Wilo-Drain TS 40/12 und 40/16 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Dimension Drawing, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29Wilo-Drain TS... . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30Wilo-Drain CP 32, CP 50, CP 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Dimension Drawing, Dimensions, Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 31Wilo-Drain LP 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 33Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 34Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 35Wilo-Drain TC 40, TP 50/65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 39Wilo-Drain TC 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Dimension Drawing, Dimensions, Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 41Wilo-Drain TP 50, TP 65 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42Terminal Diagram, Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 44Dimension Drawing, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46Hot Water . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Wilo-Drain TMT/TMC, VC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 48Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 49Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50Wilo-Drain TMT/TMC . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Dimension Drawing, Dimensions, Weights . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 51Wilo-Drain VC 32, VC 40 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52Pump Curves, Dimension Drawing, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 528 As of: 06/2004 - Subject to change without prior notice


<strong>Contents</strong>Submersible pumpsSewage/Faeces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Wilo-Drain TP 40 S/25, TP 40 S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 53Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 54Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 55Wilo-Drain TP 40 S/25 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Dimension Drawing, Dimensions, Weight . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 56Wilo-Drain TP 40 S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Pump Curves, Terminal Diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 57Dimension Drawing, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 58Wilo-Drain TP 40 S/25, TP 40 S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 59Wilo-Drain STC 80/100, STS 80/100, TP 80-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 61Pump Equipment/Function STC 80/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 63Pump Equipment/Function STS 80/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 64Pump Equipment/Function TP 80-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 65Technical Data STC 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 66Technical Data STC 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 68Technical Data STS 80/100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 70Technical Data TP 80 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 72Technical Data TP 100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 73Technical Data TP 100, TP 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 74Wilo-Drain STC 80 /100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 75Dimension Drawings, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 77Wilo-Drain STS 80 /100 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 79Terminal Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 80Dimension Drawings, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 81Wilo-Drain TP 80, TP 100, TP 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 83Terminal Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 87Dimension Drawings, Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 88Wilo-Drain STC 80/100, STS 80/100, TP 80-150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 91Wilo-Drain TP 80, TP 100, TP 150 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 94Electrical Accessories Wilo-Drain . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 95Description of Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 97Submersible pumpsAs of: 06/2004 - Subject to change without prior notice9


Sewage DisposalPlanning GuideUntreated sewage from buildings, as well as rainwater from roofs,courtyards or other catchment areas, that cannot be drained naturallyby gravity flow by means of the local sewer system must first belifted to a sufficiently high level by pump stations or lifting plantsbefore the fluid can be discharged into the sewer system. How thissewage is disposed of depends on the type of material handled.Wilo submersible pumps and sewage lifting plants have been specificallydesigned to meet these differing requirements. Wilo pumps andlifting plants all comply with applicable EN guidelines.Planning and design of wastewater and sewage disposal from buildingsand sites must be carried out in compliance with local drainageregulations and DIN EN 12050/12056, "Wastewater lifting plants forbuildings and sites." In this context, a distinction is made betweensewage disposal from outlets above the local backflow level, whichmust be discharged into the public sewage network by natural gravityflow, and sewage from outlets whose trap water levels are belowthe local backflow level. The backflow level is defined as at least thetop of the street gutter (kerb edge), but a higher level may be prescribedby the local authorities.Sewage (rain and wastewater) that collects below the backflow levelmust be discharged into the public sewage network by means ofautomatic lifting plants – Wilo sewage lifting plants or Wilo submersiblepumps.Calculating the required pump/plant capacityFlow rate Qp [l/s]:This capacity is the sum of the wastewater inflow Qs and rainwaterinflow Qr and must be measured in accordance with EN 12050/EN12056:Qs = Wastewater rate [l/s] is the sum of sewage from all fixtures withconsideration of simultaneity.Qr = Rainwater rate [l/s] is the product of rainwater collected, drainagefactor and the catchment area.Delivery head H tot [m]:This is the sum of the difference in height between the lowest collectortank level and the lowest point of the discharge pipe loop +the total pipe friction losses Hf [m] in the pressure line.Note: When selecting a lifting plant, note that the pressure differencebetween the delivery head at nominal flow rate (note minimumflow rate) and the delivery head at null flow rate must be approx.2-3 m at the operating point for the check valve body to open.For more information on planning:See the Wilo planning manual on "Sewage Disposal".Sewage DisposalPlanning GuideSpecific requirements that must be taken into account in the planningand construction of drainage systems in accordance withDIN 1986-100 EN 12050 regulations include the following:– Lifting plants must be designed to guarantee a minimum flowvelocity of 0.7 m/s with a pressure line of the specified nominaldiameter.Prescribed minimum nominal diameters:Wastewater lifting plant - DN 32Sewage lifting plant - DN 80 (without separator/macerator)– The pressure line of a lifting plant must be equipped with a checkvalve body and guided so that its lowest point is above the backflowlevel. The pressure line must not be connected to wastewaterdownpipes.– Wastewater gate valves must be fitted (inlet and discharge ends)in accordance with DIN 1986-100 and EN 12050/EN 12056 regulations.– Vent pipes from the lifting plant must be carried above roof level.The minimum pipe nominal diameter for sewage lifting plants isDN 70.– Feed lines must be laid with sufficient gradient (at least 1:50).– Pipelines through masonry should be laid flexibly.– An automatic standby pump must be provided if the sewage pipecannot cope with interrupted discharge.– Switchboxes and signal components must be installed in a dry andeasily accessible location; alarm components must be clearly visible.– Lifting plants must be regularly maintained.– Installation rooms must have adequate ventilation and lighting.A clearance of not less than 600 mm must be provided above andaround all control elements of the plant and parts which requiremaintenance.The lifting plant must firmly anchored to prevent buoyancy.– Sewage containing petroleum oils or hazardous substances mustbe disposed of via an oil or petrol trap, sewage containing fats via agrease trap and wastewater containing sand via a sand trap. Sewagecontaining acidic substances must first be neutralised.10 As of: 06/2004 - Subject to change without prior notice


Sewage DisposalPlanning GuideWastewater lifting plant (sewage without faeces)double pumps - Wilo-Drain TwisterWilo-Drain Twister double-pumpdrainage station1 Submersible pump (2x)2 Pressure line DN 32 withY-piece3 Check valve body4 Backflow loop5 Backflow level6 Sewer7 Switchgear8 Float switch for leveland alarm monitoringSubmersible pumpsBackflow loop installationIf possible, the backflow loop should beinstalled directly above the lifting plant. Thesewage pipe leading off the loop should beinstalled at a gradient to the mains sewerconnection.Wastewater and sewage lifting plant (sewage including faeces) –Wilo-DrainLift XXL double pump unitVentilationInlet11152 3913 4Drain pump1087612Backflow level(usually roadtops)1 Gate valve DN 100 or DN 1502 Single ended flanged nipple withhose and hose clips DN 100 orDN 1503 Flexible hose connector forvent line4 Tank connection kit withpump, 2 gate valves andvent flange with hose5 Hand diaphragm pump 1 1 /2"6 Check valve body DN 80 orDN 1007 Gate valve DN 80 or DN 1008 Single ended flanged nipple with hoseand hose clips DN 80 or DN 1009 3-way stopcock10 Y-pipe DN 80 or DN 10011 Microprocessor-controlledswitchgear12 KAS, mini alarm switchgear withsignal bell13 Flexible hose connector forHand-held diaphragm pumpsAs of: 06/2004 - Subject to change without prior notice11


Wilo-Drain TM/TMW 32Duty chart (2 -pole, 50 Hz)H[m]1086Wilo-Drain TM/TMW 32Submersible PumpsProduct OverviewWilo-Drain Submersible Pumps• Basement drainage pump• Applications:Pumping clear or slightly soiledwater from tanks, shafts or pits.4200 24681012Q[m 3 /h]Submersible Pumps Wilo-Drain Submersible Pumps Product OverviewWilo-Drain TS 40, 40-12, 40-16, 50, 65 Duty chart (2-pole, 50 Hz)H[m]20161284TS 40TS 50TS 65Wilo-DrainTS 40 - TS 65• Submersible wastewater pump• Applications:Pumping wastewater containing solidswith a max. diameter of 10 mm from– Building and surface drainage– Environmental protection and sewagefarm technology– Industrial and process engineering00 4 8 1216 20 24 28 32 36 40 44 48 52Q[m 3 /h]Wilo-Drain CPDuty chart (2-pole, 50 Hz)H[m]Wilo-DrainCP 32-8022201816141210864200 4 8 12 16 20 24 28 32 36 40 44 48 52 56 Q[m 3 /h]CP 50CP 32 CP 80• Submersible wastewater pump• Applications:Pumping wastewater containing solidswith a max. diameter of 10 mm from– Excavation ditches, ponds and shafts– Flooded basements– Use in fountainsWilo-Drain LP 40Duty chart (2-pole, 50 Hz)H[m]10864Wilo-DrainLP 40• Self-priming wastewater pump• Applications:Pumping wastewater from– Excavation ditches and ponds– Spraying/irrigation of gardens andlawns– Mobile drainage20 0 2 4 6 8 10 12Q[m 3 /h]Wilo-Drain TMT/TMCDuty chart (2-pole, 50 Hz)H[m]1086Wilo-DrainTMT/TMC• Wastewater pumps• Applications:Industrial and municipal use, for examplefor condensate, hot water and aggressivemedia420 0 4 8 12 16Q[m 3 /h]12 As of: 06/2004 - Subject to change without prior notice


Submersible PumpsProduct AdvantagesWilo-Drain Submersible PumpsWilo-Drain TM/TMW 32• Self-cleaning pump shaft• Prevents odour build-up from fluids• Easy to install• High level of operating safety• Simple to useSubmersible pumpsWilo-Drain TS 40, 40-12, 40-16, 50, 65• INOX & Composite• Detachable power cable• Wide range of performance levelsProduct AdvantagesWilo-Drain CP• Long working life• High level of operating safety• Can be operated in "slurping" mode (simultaneous air and water intake)• Suitable for continuous operation• Easy to handleWilo-Drain LP 40• High level of operating safety• Sea water-resistant• Easy to handle• Simple to useWilo-Drain TMT/TMC• High resistance to extreme temperatures• Suitable even for aggressive mediaAs of: 06/2004 - Subject to change without prior notice13


Wilo-Drain VCWilo-Drain TC 40Duty chart (2-pole, 50 Hz)H[m]1816VC 40/20141210864VC 32/1020 0 2 4 6 8 10 12 14Duty chart (2-pole, 50 Hz)H[m]108642TC 40/10TC 40/8Wilo-DrainVC 32-40Q[m 3 /h]Wilo-Drain TC 40Submersible PumpsProgram OverviewWilo-Drain Submersible Pumps• Vertical wastewater pump• Applications:Pumping wastewater– Containing solids with a maximumdiameter of 5 mm or 7 mm (VC 40)– Substances with temperatures up to100 °C– from pump sumps– containing condensate– from basements at risk of floodingProgram Overview• Submersible wastewater pump• Applications:Pumping heavily contaminated fluidsin– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewagefarm technology– Industrial and process engineering0 0 2 4 6 8 10 12 14Q[m 3 /h]Wilo-Drain TP 50/65Duty chart (2-pole, 50 Hz)H[m]20161284TP 50TP 65Wilo-DrainTP 50, TP 6500 4 8 12 16 20 24 28 32 36 40 44 48 52Q[m 3 /h]• Submersible wastewater pump• Applications:Pumping heavily contaminated fluidsin– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewagefarm technology– Industrial and process engineeringWilo-Drain TP 40 S/25Duty chart (2-pole, 50 Hz)H[m]2016128400 2 4 6 8 10Wilo-DrainTP40 S/25Q[m 3 /h]• Submersible sewage pumpwith macerator• Applications:Pumping domestic sewage containingfaeces from individual fixtures. Thepatented macerator reduces the solidcontents of the sewage flow into amedium containing smaller particleswhich can be more easily conveyed.Wilo-Drain TP 40 SDuty chart (2-pole, 50 Hz)H[m]3228242016128400 2 4 6 8 10 12 14 16Wilo-DrainTP40 SQ[m 3 /h]• Submersible sewage pumpwith macerator• Applications:Pumping domestic sewage containingfaeces. The patented maceratorreduces the solid contents of sewageflow to a medium containing smallerparticles which can be more easilyconveyed.14 As of: 06/2004 - Subject to change without prior notice


Submersible PumpsProduct AdvantagesWilo-Drain Submersible PumpsWilo-Drain VC• Built-in motor protection• Extended periods of use• Simple start up procedure• Pump connection outside pumping medium area• Extended standstill periods possibleSubmersible pumpsWilo-Drain TC 40• Simple operation thanks to the built-in float switch• Straightforward installation with built-in mounting foot• Stainless steel mounting foot• Large free ball passageProduct AdvantagesWilo-Drain TP 50/65• INOX & Composite• Detachable power cable• Design variant with explosion protection• Wide range of pump curvesWilo-Drain TP 40S/25• Non-clogging• High level of operating safety• Stainless steel motor• Internal cutter allows drawing cutting action• Patented maceratorWilo-Drain TP 40S• Non-clogging• Internal cutter allows drawing cutting action• High level of operating safety• Patented maceratorAs of: 06/2004 - Subject to change without prior notice15


Wilo-Drain STC 80/100Wilo-Drain STS 80/100Wilo-Drain TP 80/100/150Duty chart (2/4-pole, 50 Hz)H[m]605040302010Duty chart (4-pole, 50 Hz)H[m]201510STC 80Duty chart (4-pole, 50 Hz)STC 1000 40 80 120 160 2005Wilo-DrainSTC 80/10000 50 100 150 200H[m]252015105TP 80STS 80TP 100STS 100TP 150Q[m 3 /h]Wilo-DrainSTS 80/10000 50 100 150 200 250 300Q[m 3 /h]Wilo-DrainTP80 - TP150Q[m 3 /h]Submersible PumpsProduct OverviewWilo-Drain Submersible Pumps• Submersible sewage pump• Applications:Pumping faeces, municipal and industrialsewage containing long-fibre particlesin the following areas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewagefarm technology– Industrial and process engineering• Submersible sewage pump• Applications:Pumping faeces, municipal and industrialsewage containing long-fibre particlesin the following areas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewagefarm technology– Industrial and process engineering• Submersible sewage pump• Applications:Pumping faeces, municipal and industrialsewage containing long-fibre particlesin the following areas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewagefarm technology– Industrial and process engineeringProduct Overview16 As of: 06/2004 - Subject to change without prior notice


Submersible PumpsProduct AdvantagesWilo-Drain Submersible PumpsWilo-Drain STC 80/100• Separation chamber with double seal• Wide range of performance levelsSubmersible pumpsWilo-Drain STS 80/100• Detachable power cable• Stainless steel motorWilo-Drain TP 80/100/150• INOX & Composite• Explosion protection fitted as standard• Lightweight• Detachable power cable• Cooling jacket fitted as standard• Corrosion-resistant (when used to drain swimming pools, for example)Product AdvantagesAs of: 06/2004 - Subject to change without prior notice17


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPProduct DescriptionDesignThis submersible pump is suitable for stationary, fully automaticoperation. A sufficiently long hose is connected to the pump dischargeport for mobile use, while a solid pipe is fitted for stationaryuse. A fault current safety switch (mandatory for outdoor installations)for a breaking current of 30 mA must be fitted by the customer,in accordance with EN 60335-2.41.Wilo-Drain TM/TMWBasement drainage pumpType keyExample: Wilo-Drain TMW 32/8 HDTM Submersible pumpTMW Submersible pump with turbulator32 Nominal diameter of delivery connection (DN 32)/8 Max. delivery head (m)HD Suitable for handling abrasive pumping mediaApplicationsTM 32Pumping clear or slightly soiled water from tanks, shafts or pits withthe pump installed vertically.TMW 32Submersible pumps that are used in pump sumps and exposed tosoapy water from washing machines, washbasins and showers (forexample) have a considerably shorter working life. The large amountof suspended matter contained in this water gradually accumulatesin the pump shaft over time, leaving a slimy residue in the pumpsump and in the pump itself.To prevent this, regular sump cleaning is required, a procedure whichis both time-consuming and expensive. Furthermore, the problem ofsludge disposal and possible hygiene implications cannot bedefinitely evaluated at this stage. The Wilo-Drain TMW 32 Twisterprovides an ideal solution in this case.In addition, for TMW:The design of the Wilo-Drain Twister ensures constant circulation inthe pump suction area, thus ensuring that the pump sump is keptclean.Due to the constant turbulence and the fact that this eliminates thesuspended matter, odours from the materials handled are notallowed to build up. Maintenance intervals are extended.When you deactivate the twister (see the installation and operatingmanual), the pump curve is increased by 1 m.MotorForced-flow casing cooled, stainless steel-cased, dry electric motorwith integrated thermal motor protection and automatic restart.CableA 10 m permanently wired power cable is required for outdoor installationsin Germany (VDE), but different regulations may apply inother countries.Pump/Motor SealsThere is a mechanical seal on the impeller, a shaft seal on the motorand an oil chamber between both seals.Scope of deliveryA fully assembled pump with cable, plug and fitted float switch isprovided, together with installation and operating manual.Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPProduct Description18 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPProduct DescriptionDesignMonobloc submersible wastewater pump for vertical wet sumpinstallation.– INOX & Composite– Lightweight– Detachable power cable– Corrosion-proofMotorThree-phase current asynchronous motor 3~400 V, 50 Hz orAC motor 1~230 V, 50 HzSubmersible pumpsTS ... H TS 40/..Wilo-Drain TSSubmersible wastewater pump, 2-poleType keyExample: Wilo-Drain TS 40 H 90/5.5-1 ATS Submersible wastewater pump40 Connection 40 (= Rp 1 1 / 2 )50 (= Rp 2)65 (= Rp 2 1 / 2 )H Impeller type: H = semi-open90 Impeller nominal diameter [mm]/5.5 Performance rating P 2 [kW] = value/10 = 0.55 kW-1 1 = alternating current (single-phase) (EM)Not specified = three-phase current (DM)A With float switch, power cable and plugNot specified:Power cable with bare cable endApplicationsWilo-Drain TS submersible pumps are ideal for conveying wastewaterthat contains solid matter with a maximum diameter of 10 mmfor:– Building and surface drainage– Environmental protection and sewage farm technology– Industrial and process engineeringThe pumps may be used in either:– Stationary wet sump installations– Portable wet sump installationsMotor protectionAlternating current:Three-phase current:Thermal winding contacts (WSK)Motor protection must be installed onsite from 1.1 kW = Thermal windingcontactsBearingsThe motor shaft is bedded in permanently lubricated, low-maintenanceroller bearings.Hydraulic dataSemi-open impeller with a free ball passage of 10 mm. May beinstalled without base. Fitted with a practical, vertical discharge port.Scope of deliveryTS 40/12-16 AFully assembled pump with built-in capacitor, 5 m power cable,shockproof plug and attached float switch, hose nozzle, built-innon-return valve, installation and operating manualTS 40-65Fully assembled pump with 10 m power cable and bare cable end forThree-phase current version 3~400 V, 10 m power cable and switchbox (on/off; terminal rail) for AC version 1~230 V, installation andoperating manual.TS 40 with built-in non-return valve.A model:Fully assembled pump with 10 m power cable, plug[CEE/Schuko] and float switch.As of: 06/2004 - Subject to change without prior notice19


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPProduct DescriptionWilo-Drain CPSingle-stage excavation ditch pumpType keyExample: Wilo-Drain CP 32/17-1~230CP Contractor Pump32 Nominal diameter (DN 32, DN 50, DN 80)/17 Maximum delivery head [m]1~230 AC motor3~400 Three-phase motorApplicationsDraining of excavation ditches, basements, shafts and ponds. Thepump is perfectly suited for use in fountains.DesignSubmersible pump with double mechanical seal. It is designed to beparticularly hard-wearing and robust. The electrical drive is sealedfrom the flow medium by means of 2 mechanical seals and an internaloil seal chamber. The motor compartment is filled with oil.The hydraulic system is equipped with multi-vane impellers.Scope of deliveryFully assembled pump with 10 m power cable and alternating currentor Three-phase plug, installation and operating manual.20 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPPump Equipment/FunctionPump Equipment/FunctionWilo-DrainTM/TMW 32Wilo-DrainTS 40Wilo-DrainTS 50Wilo-DrainTS 65Wilo-DrainTS 40/12/16Wilo-DrainCP 32/50/80Operating mode S3 (intermittent service)Frequency switching/h [%] 25 25 25 25 25 –Max. frequency switching/h 60 70 50 40 50 –Recommended frequency switching/h 20 20 20 20 20 –Operating mode S1 (continuous service)Motor below water • • • • • •Motor above water – – – – – •Pump/motor sealsIn pumping medium area: Mechanical seal • • • • • •On the motor compartment side: Mechanical seal – – – – – •Shaft seal • • • • • –Oil seal chamber • • • • • •DesignWet sump installation Stationary • • • • • •Portable • • • • • •Submersible • • • • • •Open multi-vane impeller • • • • – –Closed multi-vane impeller – – – – – •Free-flow impeller – – – – •TurbulatorMaterials•(TMW only)•(CP 32/23 andCP 80 only)– – – – –Motor Cast aluminium – – – – – •Stainless steel • • • • • –Pump Plastic • • • • • –EquipmentMotor monitor (temperature)Cast iron – – – – – •••(3~400 Vmodel only)Explosion protection – –•(3~400 Vmodel only)•(3~400 Vmodel only)• – •• – –Forced-flow casing cooling • – – – –Pre-assembled • – – – • –•(CP 80 only)Power cable [m]310 for: TM 32/8 and 10 10 10 5 10TMW 32/11HDDetachable power cable – • • • – •Attached float switch –/• optional optional – • –Built-in check valve body – • – – • –Capacitor box for 1~230 V – • • • –•(CP 32/17only)Hose connection – – – – • –Submersible pumps• = available, – = not availableAs of: 06/2004 - Subject to change without prior notice21


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPTechnical DataWilo-Drain TM/TMWWilo-Drain TSTechnical DataApproved fluidsWashing machine soap and water mixture(without long-fibre particles)TM 32/8TMW 32/8TMW 32/11TMW 32/11 HDTS 40...H 90/5.5TS 40...H 100/7.5TS 50...H 111/11• •Water from car wash facilities • •Non-chlorinated pool water • •Water from firefighting systems • •Heating water (T max = 35 °C) • •Boiler feed water • •Condensate – • •Cooling (condenser) water • •Clean water • •Untreated wastewater • –Drainage water • •Partially desalinated water – • –Rainwater • • •Swimming pool water – • –Sea water – • –Wastewater • • •Aggressive media – • –PerformancePower consumption P 1 1~230 V [kW] 0.5 0.45 0.75 0.75 1.0 1.3 1.5 – – –Power consumption P 1 3~400 V [kW] – – – – 1.0 1.1 1.5 2.0 2.9 2.9Rated motor power P 2 [kW] 0.37 0.37 0.55 0.55 0.55 0.75 1.1 1.5 2.2 2.2Rated current for 1~230 V [A] 2.2 2.1 3.6 3.6 4.0 5.5 7.7 – – –Rated current for 3~400 V [A] – – – – 2.0 2.0 3.2 3.6 5.1 5.1Speed [rpm] 2,900 2,900MotorProtection class for max. submersion depth IP 68 IP 68Insulation class F FFrequency switching [per hour] 60 70 50 40PumpMax. noise level at min. level [dBA] 52 55 54 54 –Submersion depth, max. [m] 3 10Fluid temperature [°C] 3 – 35 3 - 35Fluid temperature, short periods up to 3 min [°C] 90 –Cable typeH07RN-FH05 RN-FH07RN-FTS 50...H 122/15TS 50...H 133/22OZOFLEX (PLUS) H07 RN-F - Oil-resistantCable length [m] 10 3 3 10 10 10 10 10 10 10Cable cross-section 1~230 V [mm 2 ] 1 1 1 1 1 1 1 – – –Cable cross-section 3~400 V [mm 2 ] – – – – 1 1 1 1.5 1.5 1.5Plug Schuko Schuko/CE – – –Type of power cable Fixed Plug (detachable)Activation type direct directExplosion protection (EEx d II B T4) – – – – – –ThreephasecurrentonlyTS 65...H 117/22• • •Free ball passage [mm] 10 10 10 10 10 10 10 10 10 1022 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPTechnical DataWilo-Drain TM/TMWWilo-Drain TSTechnical DataDimensionsDischarge port [DN/Rp] 1 1 / 4 1 1 / 4 1 1 / 4 1 1 / 4 1 1 / 2 1 1 / 2 2 2 2 2 1 / 2Hose connection [mm] 35 – – – – – – – – –Weight [kg] 5.2 4.7 6.2 6.2 13.5 14.5 21 22 23 24MaterialsTM 32/8Pump housing PP-GF30 Polypropylene PolyurethaneImpeller PP-GF30 PolypropyleneShaft 1.4021 C10/1.4404Shaft seal on motor side NBR NBRMotor housing 1.4301 1.4404 1.4301TMW 32/8TMW 32/11TMW 32/11 HDTS 40...H 90/5.5TS 40...H 100/7.5TS 50...H 111/11TS 50...H 122/15TS 50...H 133/22TS 65...H 117/22Submersible pumps• = available or authorised, – = not available or not authorisedNote on Wilo-Drain TS:ModelsTS 40... H 90/5.5TS 40... H 100/7.5TS 50... H 111/11also supplied as A model (without explosion protection, but including float switch and plug 1~230 V).As of: 06/2004 - Subject to change without prior notice23


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPWilo-Drain TS... Wilo Drain CP ...Technical DataApproved fluidsWashing machine soap and water mixture (without long-fibreparticles)TS 40/12-ATS 40/16-A32/17-1 ~23032/17-3 ~40032/23-1 ~23032/23-3 ~40050/12-1 ~23050/12-3 ~400• • • • • • •Water from car wash facilities • • • • • • •Non-chlorinated pool water • • • • • • •Heating water • • • • • • •CondensateCooling (condenser) waterConditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.50/16-3 ~400Conditionallyresist.Conditionallyresist.Clean water • • • • • • •Drainage water • • • • • • •Partially desalinated waterConditionallyresist.Conditionallyresist.80/20-3 ~400Conditionallyresist.Conditionallyresist.– – – – –Rainwater • • • • • • •Swimming pool waterSea waterConditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.– – – – –– – – – –Wastewater, flood and river water • • • • • • •Highly dilute alkalinesMedia with low aggressivenessPerformanceConditionallyresist.Conditionallyresist.Conditionallyresist.Conditionallyresist.– – – – –– – – – –Power consumption P 1 1~230 V [kW] 0.5 0.9 1.2 1.2 1.2 – –Power consumption P 1 3~400 V [kW] – – 1.2 1.2 1.2 2.0 2.9Rated motor power P 2 [kW] 0.4 0.75 0.75 0.75 0.75 1.3 2.36Rated current for 1~230 V [A] 2.6 4.6 5.3 5.3 5.3 – –Rated current for 3~400 V [A] – – 2.1 2.1 2.1 3.35 4.7Speed [rpm] 2,900 2,900 2,900 2,900 2,900 2,900 2,900MotorProtection class for max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68Insulation class B F F F F FFrequency switching [per hour] 20 15 15 15 15 15PumpMax. noise level at min. level [dBA] 70 70 70 70 70 70 70Submersion depth, max. [m] 5 12 12 12 12 12Fluid temperature, max. [°C] 35 40 40 40 40 40Cable typeH07 RN-FCable length [m] 5 10 10 10 10 10Cable cross-section 1~230 V [mm 2 ] 1 1 4G1.5Cable cross-section 3~400 V [mm 2 ] – – 4G1.5Type of power cableActivation typedetachable/plugExplosion protection –Internal mechanical seal SiC/SiC SiC/SiCSteatite/carbondirectSteatite/carbonSteatite/carbonSteatite/carbonCarbon/AluminiumOxideExternal mechanical seal SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiC SiC/SiCFree ball passage [mm] 10 10 9 5 10 10 524 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TM/TMW, TS 40-65, TS 40/12, TS 40/16, CPTechnical DataWilo-Drain TS... Wilo Drain CP ...DimensionsDischarge port DN R1 1 / 2 R1 1 / 2 G1 1 / 4 G1 1 / 4 G2 G2 G3Weight [kg] 13 14 14.5 14.5 15.5 18.5 29.0MaterialsPump housing PP–GF30 EN-GJL-250Impeller PP–GF30 EN-GJL-250Shaft 1.4404/1.0402 1.4021Static seals NBR NBRMotor housing 1.4404 Aluminium• = available or authorised, – = not available or not authorisedTS 40/12-ATS 40/16-A32/17-1 ~23032/17-3 ~40032/23-1 ~23032/23-3 ~40050/12-1 ~23050/12-3 ~40050/16-3 ~40080/20-3 ~400Submersible pumpsAs of: 06/2004 - Subject to change without prior notice25


Wastewater/DrainageWilo-Drain TM/TMWPump Curves, Dimension Drawings, Dimensions, Weights, AccessoriesTM/TMW 322-pole, 50 Hz[m]1083Wilo-Drain TMW 32Wilo-Drain TM/TMWPump Curves, Dimension Drawings, Dimensions, Weights, Accessories1 = TMW 32/82 = TM 32/83 = TMW 32/11H624120 0 2 4 6 8 10 12 14Q[m 3 /h]Dimension drawingsInstallation schematics for installations with switchgears1 ~ 230V 50 HzHminAlarmonOnPeak loadh1hadjustableLBase load andalarmDOffOffB min350 x 3501000 x 500Dimensions, weightsDischargeportHoseconnectionHeight oftheconnectionPumpdiameterShaftdimensions,min.Switch-onlevel± 8 mmSwitch-offlevel± 8 mmEmptyinglevel,min.– L D H x B – h1 – –Rp [mm] [kg]TM 32/8 – 35 294 165 – – – 14 5.2TMW 32/8 1 1 / 4 – 293 165 280x350 250 102 30 4.7TMW 32/11 1 1 / 4 – 323 165 330x350 280 102 30 6.2TMW 32/11 HD 1 1 / 4 – 323 165 330x350 280 102 30 6.2WeightAccessoriesCheck valve body Rp 1 1 / 4with drain plug, plastic, nominal pressurePN 4 bar26 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TS 40, TS 50, TS 65Pump Curves, Terminal DiagramTSWilo-Drain TS 40, TS 50, TS 65Pump Curves, Terminal Diagram2-pole, 50 Hz[m]2420Wilo-Drain TS1 = TS 40 H 90/5.52 = TS 40 H 100/7.53 = TS 50 H 111/114 = TS 50 H 122/155 = TS 50 H 133/22Submersible pumps166 = TS 65 H 117/22H12Pump curves for TS 40 without non-return valveAll pump curves shown are based on a density ofρ = 1 kg/dm 38543462100 4 8 12 16 20 24 28 32 36 40 44 48 52 [m 3 /h]0 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15[l/s]QTerminal diagram1 ~ 230 V, 50 HzL 1 N PE Float - L 1 N PEswitchWA≤ 1,1 kW3 ~ 400 V, 50 HzL 1 L 2 L 3PEgreen/yellow> 1,1 kW3 ~ 400 V , 50 HzPEL 1 L 2 L 3 green/yellow WSK WSKTo switch rotational direction,switch any two phasesTo switch rotational direction,switch any two phasesAs of: 06/2004 - Subject to change without prior notice27


Wastewater/DrainageWilo-Drain TS 40, TS 50, TS 65Dimension Drawing, Dimensions, WeightsDimension drawingDimension Drawing, Dimensions, WeightsModel withbare cable end150ACModel with flat switchand connector (-A)Three-phase current80 110 80 10 m150AC12010 m22512080PG 13PG 11 PG 13PG 16-21PG 111mØ DRpL6HL2L1Ø D 2D 1Dimensions, weightsDischargeportDimensionsWeight– L1 L2 L6 D H D1 D2 –Rp [mm] [kg]TS 40 H 90/5.5 DM/A 1 1 / 2 341 412 127 112.4 124 275 220 13.5TS 40 H 90/5.5 EM/A 1 1 / 2 341 412 127 112.4 124 275 220 13.5TS 40 H 100/7.5 DM/A 1 1 / 2 341 412 127 112.4 124 275 220 14.5TS 40 H 100/7.5 EM/A 1 1 / 2 341 412 127 112.4 124 275 220 14.5TS 50 H 111/11 DM/A 2 360 440 170 128 132 375 294 21TS 50 H 111/11 EM/A 2 360 440 170 128 132 375 294 21TS 50 H 122/15 DM 2 360 440 170 128 132 375 294 22TS 50 H 133/22 DM 2 387 472 170 138 132 375 294 23TS 65 H 117/22 DM 2 1 / 2 398 483 170 138 149 375 294 2428 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TS 40/12 and 40/16Pump Curves, Dimension Drawing, DimensionsTS 40/12 and TS 40/16Wilo-Drain TS 40/12 and 40/16Pump Curves, Dimension Drawing, Dimensions2-pole, 50 Hz[m]1612TS 40/16-AWilo-Drain TS 40Submersible pumpsH8TS 40/12-A400 4 8 12 16Q[m 3 /h]Dimension drawingDB30 mmACDimensionsDimensionsA B C D[mm]TS 40/12-A 390 273 245 DN 40/ R1 1 / 2TS 40/16-A 407 290 245 DN 40/ R1 1 / 2As of: 06/2004 - Subject to change without prior notice29


Wastewater/DrainageWilo-Drain TS...Mechanical AccessoriesStationary wet sump installation32Wilo-Drain TS...Mechanical AccessoriesCheck valve body (Item 2)TS 40 comes standard with built-in non-returnvalve.TS 40 TS 50 TS 65Rp 1 1 / 2 Rp 2 Rp 2 1 / 2all female thread, cast iron (EN-GJL)Gate valve (ball valve; Item 3)TS 40 TS 50 TS 65Rp 1 1 / 2 Rp 2 Rp 2 1 / 2Female thread, brass, nickel-platedPortable wet sump installationbaHose connection, incl. Hose clamp (Item 12)TS 40 TS 50 TS 65R 1 1 / 2 R 2 Rp 2 1 / 2Plastic Plastic Stainless steela 40 mm 60 mm 70 mmb 80 mm 90 mm 100 mmall male threadGeka solid coupling (Item 19)BrassTS 40: R 1 1 / 2 male thread14 or 20Geka hose coupling (Item 20)Brass, fits Geka solid coupling, incl. hose clipTS 40: for hose inner diameter of 40 mm12, 13 or 19Storz fixed coupling (Item 13)Aluminium, 52-CTS 50 TS 65G 2 G 2 1 / 2Male thread, cam distance 66 mmStorz hose coupling (Item 14)Aluminium, 52-C, incl. hose clipTS 50 = distance between cams 66 mm, for hoseinside diameter 52 mm30 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain CP 32, CP 50, CP 80Pump Curves, Dimension Drawings, Dimensions, WeightsCPWilo-Drain CP 32, CP 50, CP 80Pump Curves, Dimension Drawings, Dimensions, Weights2-pole, 50 HzH[m]242220181614Wilo-Drain CP1 = CP 32/232 = CP 32/173 = CP 50/124 = CP 50/165 = CP 80/20Submersible pumps12108644321 200 4 8 12 16 20 24 28 32 36 40 44 48 52 56 60Q5[m 3 /h]Dimension drawingsBaBHDNaHaDNH1D58B1a1DDNHH1B1BDCP 32CP 50CP 80Dimensions, weightsDischarge port Dimensions Weight– B1 H H1 D a B a1 –DN [mm] [kg]Wilo Drain CP 32/17 - 23 G 1 1 / 4 216 387 122 163 118 230 – 14.5Wilo Drain CP 50/12 G2 227 380 – – 90 195 90 15.5Wilo Drain CP 50/16 G2 228 415 – – 90 195 90 18.5Wilo Drain CP 80/20 G2 – 415 438 236 140 304 – 29.0As of: 06/2004 - Subject to change without prior notice31


Wastewater/DrainageWilo-Drain LP 40Product DescriptionWilo-Drain LPSelf-priming wastewater pumpType keyExample: Wilo-Drain LP 40/10LP Lifting Pump40 Nominal diameter (DN 40)/10 Max. delivery head [m]ApplicationsThe Wilo-Drain LP 40 self-priming wastewater pump is suitable forconveying large quantities of clean or slightly soiled water. It is usedfor in gardening and agriculture, as well as in industry.Because it isresistant to salt water, it can also be used in navigation (bronzemodel).DesignPortable self-priming centrifugal pump, mounted on vibration-freepolypropylene baseplate for stability.Maximum suction height 6 m.Scope of deliveryPump includes oval mating flange with female thread Rp 1 1 / 2 , carryinghandle and installation and operating manual.Wilo-Drain LP 40Product Description32 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain LP 40Pump Equipment/FunctionPump Equipment/FunctionWilo-Drain LP 40Operating mode S1 (continuous service)Motor air-cooledPump/motor sealsIn pumping medium area: Mechanical seal •DesignDry sump installation Stationary •Free-flow impellerMaterialsMobileMotor Cast aluminium •Pump PP–GF30 •EquipmentMotor monitor (temperature)Oval mating flangesBronze••••••Submersible pumps• = available, – = not availableAs of: 06/2004 - Subject to change without prior notice33


Wastewater/DrainageWilo-Drain LP 40Technical DataTechnical DataWilo Drain LP 40Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterSalt waterHeating waterCooling (condenser) waterClean waterDrainage waterRainwaterWastewater, flood and river waterHighly dilute alkalinesPerformancePower consumption P 1 1~230 V [kW] 0.55Rated motor power P 2 [kW] 0.4Rated current for 1~230 V [A] 2.3Speed [rpm] 2,900MotorProtection class IP 44Insulation classPumpFluid temperature [°C] 3 - 35Mechanical seal• = available or authorised, – = not available or not authorised•••••••••••BCarbon/ceramicFree ball passage [mm] 5DimensionsDischarge port DN 40Hose connection diameter [mm] 40Weight [kg] 12MaterialsPump housingImpellerPolypropyleneBronzeShaft 1.4006/1.0402Static sealsMotor housingNBRAluminium34 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain LP 40Pump Curves, Dimension DrawingLP 40Pump Curves, Dimension Drawing2-pole, 50 Hz[m]108Wilo-DrainLP 40/10Submersible pumpsH64200 2 4 6 8 10Q[m 3 /h]Dimension drawingTerminal diagram1~230 V, 50 HzL N PEAs of: 06/2004 - Subject to change without prior notice35


Wastewater/DrainageWilo-Drain TC 40, TP 50/65Product DescriptionWilo-Drain TC 40Submersible wastewater pump, 2-poleType keyExample: Wilo-Drain TC 40/8TC Submersible pump40 Nominal diameter [mm]/8 Max. delivery head [m]ApplicationsWilo-Drain TC 40 submersible pumps are ideal for pumping heavilycontaminated fluids for:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewage farm technology– Industrial and process engineeringDesignMonobloc submersible wastewater pump for vertical wet sumpinstallation.MotorAC motor 1~230 V, 50 HzMotor ProtectionThermal winding contacts (WSK)Scope of deliveryFully assembled pump with 5 m power cable, plug (Schuko), floatswitch and installation and operating manual.Wilo-Drain TC 40, TP 50/65Product Description36 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TC 40, TP 50/65Product DescriptionDesignMonobloc submersible wastewater pump for vertical wet sumpinstallation.–Inox & Composite–Low weight– Detachable power cable– Corrosion-proofMotorThree-phase current asynchronous motor 3~400 V, 50 Hz orAC motor 1~230 V, 50 HzSubmersible pumpsWilo-Drain TP 50, TP 65Submersible wastewater pumpMotor protectionAlternating current:Three-phase:Thermal winding contacts (WSK)Motor protection must be installed on siteFrom 1.1 kW = thermal winding contacts(WSK)Type keyExample: Wilo-Drain TP 65 E 114/11-1ATP Submersible pump65 Nominal diameter [mm]E Impeller type: E = Single-vane impellerF = Free-flow impeller114 Impeller nominal diameter [mm]/11 Performance rating P2 [kW] = value/10 = 1.1 kW-1 1 = alternating current (single-phase) (EM)Not specified = three-phase current (DM)A With float switch and plugApplicationsWilo-Drain TP submersible pumps are ideal for pumping heavily contaminatedfluids for:– Building and surface drainage– Environmental protection and sewage farm technology– Industrial and process engineeringHigh operational reliability due to a free ball passage of 44 mm.Because of its low weight, ideally suited as an emergency/replacementpump.Suitable for:– Stationary wet sump installation– PortableBearingsThe motor shaft is bedded in permanently lubricated, low-maintenanceroller bearings.Shaft sealBidirectional mechanical seal and shaft seal. Intermediate oil chamberfor cooling and lubrication.Hydraulic dataOptionally with single-vane or free-flow impeller with a free ballpassage of 44 mm.Scope of deliveryFully assembled pump with 10 m power cable and bare cable end forthree-phase current version 3~400 V, 10 m power cable and switchbox (on/off; terminal rail) for AC version 1~230 V, and installation andoperating manual.A-version:Fully assembled pump with 10 m power cable, plug [CEE/Schuko],float switch and installation and operating manual.As of: 06/2004 - Subject to change without prior notice37


Wastewater/DrainageWilo-Drain TC 40, TP 50/65Pump Equipment/FunctionPump Equipment/FunctionWilo-Drain TC 40 Wilo-Drain TP 50 Wilo-Drain TP 65Operating mode: Intermittent service S3Frequency switching/h [%] 25 25 25Max. frequency switching/h 30 70 40Recommended frequency switching/h 20 20 20Operating mode: Continuous service S1Motor below water • • •Pump/motor sealsIn pumping medium area: Mechanical seal • • •On the motor compartment side: Shaft seal • • •Oil seal chamber • • •DesignWet sump installation Stationary • • •• = available, – = not availablePortable • • •Submersible • • •Open single-vane impeller – • •Free-flow impeller • • •MaterialsMotor Stainless steel • • •Pump Plastic – • •EquipmentCast iron • – –Motor monitor (temperature) –•(1~230 V model only)Explosion protection – –Pre-assembled••(A model only)••(3~400 V model only)•(A model only)Power cable [m] 5 10 10Attached float switchCapacitor box –••(A model only)•(A model only)––38 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TC 40, TP 50/65Technical DataWilo DrainTC ...Wilo-DrainTP ...Wilo-DrainTP ...Technical DataApproved fluidsWashing machine soap and water mixture(without long-fibre particles)TC 40/8TC 40/10TP 50 ...E 101/5.5TP 50 ...E 107/7.5TP 50 ...F 82/5.5TP 50 ...F 90/7.5TP 65 ...E 114/11TP 65 ...E 122/15TP 65 ...E 132/22• • •Water from car wash facilities – • •Pool water • • •Water from firefighting systems • • •Heating water T max < 40 °C T max < 35 °CBoiler feed water T max < 40 °C T max < 40 °CCondensate – • •Cooling (condenser) water • • •Drainage water • • •Rainwater • • •Wastewater, flood and river water • • •Faeces (free-flow impeller) – – •PerformancePower consumption P 1 1~230 V [kW] 0.66 0.94 1.0 1.3 1.0 1.3 1.5 – – 1.5 – –TP 65 ...F 91/11TP 65 ...F 98/15TP 65 ...F 109/22Submersible pumpsPower consumption P 1 3~400 V [kW] – – 1.0 1.1 1.0 1.1 1.5 2.0 2.9 1.5 1.8 2.7Rated motor power P 2 [kW] 0.5 0.6 0.55 0.75 0.55 0.75 1.1 1.5 2.2 1.1 1.5 2.2Rated current for 1~230 V [A] 3.2 4.4 4.0 5.5 4.0 5.5 7.2 – – 6.9 – –Rated current for 3~400 V [A] – – 2.0 2.0 2.0 2.0 3.2 3.8 5.2 3.2 3.6 5.1Speed [rpm] 2,850MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 30 70 40PumpSubmersion depth, max. [m] 5 10 10Fluid temperature, max. [°C] 40 35 35Cable type H07 RN-F OZOFLEX (PLUS) H07 RN-F – oil-resistantCable length [m] 5 10 10Cable cross-section 1~230 V [mm 2 ] 3x1 4x1 4x1 – – 4x1 – –Cable cross-section 3~400 V [mm 2 ] – 4x1 6x1 6x1 6x 1.5 6x1 6x1 6x 1.5Plug Schuko Schuko/CE –Type of power cablelongitudinalwatertightlongitudinal watertight/plugFlongitudinal watertight/plugActivation type direct direct directExplosion protection – –EEx d ll B T4(except 1~230 V and A models)Free ball passage [mm] 35 44 44DimensionsDischarge port [DN/Rp] 1 1 / 2 1 1 / 2 50 50 50 50 65 65 65 65 65 65Weight [kg] 9.5 12 14.5 16 14.5 16 21 22 24.5 22 24.5 24.5As of: 06/2004 - Subject to change without prior notice39


Wilo DrainTC ...Wilo-DrainTP ...Wastewater/DrainageWilo-Drain TC 40, TP 50/65Wilo-DrainTP ...Technical DataTechnical DataMaterialsPump housing EN-GJL-200 Polypropylene PolyurethaneImpeller Plastic Polypropylene Polyurethane PolypropyleneShaft 1.4005 1.4435 1.4435Pump side:Motor side:Mechanical seal(bidirectional)Mechanical seal• = available or authorised, – = not available or not authorisedCarbon/ceramicCarbon/ceramicSiC-SiCSiC-SiC– –Shaft seal – NBR NBRStatic seals NBR NBR NBRMotor housing 1.4308TC 40/8TC 40/10TP 50 ...E 101/5.5TP 50 ...E 107/7.5TP 50 ...F 82/5.5TP 50 ...F 90/7.51.4301(1.4435 steel upon request)TP 65 ...E 114/11TP 65 ...E 122/15TP 65 ...E 132/22TP 65 ...F 91/11TP 65 ...F 98/151.4301(1.4435 steel upon request)TP 65 ...F 109/2240 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TC 40Pump Curves, Dimension Drawing, Dimensions, WeightsTC 40Wilo-Drain TC 40Pump Curves, Dimension Drawing, Dimensions, Weights2-pole, 50 Hz[m]1210Wilo-Drain TC 401 = TC 40/82 = TC 40/10Submersible pumps8H6421200 2 4 6 8 10 12 14 16Q[m 3 /h]Dimension drawing5 mAH50DNH1BCDimensions, weightsDischarge port Dimensions Weight– A B C H H1 –Rp [mm] [kg]Wilo Drain TC 40/8 1 1 / 2 105 86 138 352 120 9.5Wilo Drain TC 40/10 1 1 / 2 105 86 138 367 120 12.0As of: 06/2004 - Subject to change without prior notice41


Wastewater/DrainageWilo-Drain TP 50, TP 65Pump CurvesTP 50 E2-pole, 50 Hz[m]1614Wilo-DrainTP 50 E1 = TP 50 E 101/5.52 = TP 50 E 107/7.5All pump curves shown are based on a density ofρ = 1 kg/dm 31210H86421 2000148 12 16 202428 322 3 4 5 6 7 8 93610[m 3 /h][l/s]QWilo-Drain TP 50, TP 65Pump CurvesTP 50 F2-pole, 50 Hz[m]1210Wilo-DrainTP 50 F3 = TP 50 F 82/5.54 = TP 50 F 90/7.5All pump curves shown are based on a density ofρ = 1 kg/dm 38H6423 400 4 8 12 16 20 24 28 32 [m 3 /h]0 1 2 3 4 5 6 7 8 9 [l/s]Q42 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TP 50, TP 65Pump CurvesTP 65 E2-pole, 50 HzH[m]201612Wilo-DrainTP 65 E1 = TP 65 E 114/112 = TP 65 E 122/153 = TP 65 E 132/22Submersible pumps8401 20 8 16 24 32 40 48 560 5 10 153[m 3 /h][l/s]Q23P 2 [kW]1120816 24 32 40 48 56Q[m 3 /h]TP 65 F2-pole, 50 Hz[m]1412Wilo-DrainTP 65 F4 = TP 65 F 91/115 = TP 65 F 98/156 = TP 65 F 109/2210H864264 500 8 16 24 32 40 48 [m 3 /h]0 51015 [l/s]Q26P 2 [kW]14500 8 16 24 32 40 48Q[m 3 /h]As of: 06/2004 - Subject to change without prior notice43


Wastewater/DrainageWilo-Drain TP 50, TP 65Terminal Diagram, Dimension DrawingsTerminal diagramTerminal Diagram, Dimension Drawings1 ~ 230 V, 50 HzL 1 N PE Float - L 1 N PEswitchWA≤ 1,1 kW3 ~ 400 V, 50 HzL 1 L 2 L 3PEgreen/yellow> 1,1 kW3 ~ 400 V , 50 HzPEL 1 L 2 L 3 green/yellow WSK WSKTo switch rotational direction,switch any two phasesTo switch rotational direction,switch any two phasesDimension drawing TP 50Model with barecable endAC150 80Model with float switchand connectcor (-A)Three-phase current11010 m80AC15012010 m25512060PG 13PG 11 PG 13PG 16-21PG 11801m130190Ø 112, 41504 x M16Ø 125DN:5041148130015PN 10/1698173242Ø 24660044 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TP 50, TP 65Dimension Drawings, DimensionsDimension drawing TP 65Dimension Drawings, DimensionsL4PG 13Model withbare cable endL3ACPG 11 PG 13Model with flat switchand connector (-A)Three-phase currentAC80 110 80 10 mL3 8010 m225PG 16-21PG 11L460Submersible pumps1 m130210Ø D1704 x M16Ø 145PN 10/16DN 65L1L236015115173Ø 300280600DimensionsDimensionsL1 L2 L3 L4 D[mm]TP 65 E 114/11 DM/A 425 505 – – 128TP 65 E 114/11 EM/A 425 505 150 120 128TP 65 E 122/15 DM 425 505 – – 128TP 65 E 132/22 DM 452 535 200 150 138TP 65 F 91/11 DM/A 425 505 – – 128TP 65 F 91/11 EM/A 425 505 150 120 128TP 65 F 98/15 EM 452 535 200 150 138TP 65 F 109/22 DM 452 535 – – 138As of: 06/2004 - Subject to change without prior notice45


Wastewater/DrainageWilo-Drain TP 50, TP 65Mechanical AccessoriesStationary wet sump installation TP 50 and 65154362BCADMechanical AccessoriesBase elbow incl. cable guide (Item 1)Made of cast iron 25 (EN-GJL-250), including pumpsupport, profile seal, accessories for installation andfastening to the ground, and guide pipe bracket.Complete 7 m cable guide for 3.5 m installationdepth.For connection DN 50 or DN 65. Alternatively, onsiteinstallation with 1" guide pipe possible (scopeof delivery including chain, Item 6).TP 50 TP 65A 150 180B 300 360C 150 200D 242 280Chain (Item 6)Made of galvanised steel, including stainless steelshackles, length: 5m, lifting capacity: 250 kg(included in scope of delivery of Item 1)1Check valve body (Item 2a)Rp 2-female thread, cast iron 25 (EN-GJL-250)For TP 50 only1ECheck valve body (Item 2)DN 50, cast iron 25 (EN-GJL-250), flangesPN 10/16, with unrestricted passage, cleaning portand ventilation device including installation accessories,draw. No. 53.4-309FTP 50 TP 65E 203 223F 200 240Gate valve (Item 3a)Rp 2 female thread, brass, nickel-platedFor TP 50 onlyGate valve (Item 3)DN 50, cast iron 25, (EN-GJL-250) flangesPN 10/16, incl. installation accessoriesGHKJ ITP 50 TP 65G 235 295H 150 170Y-pieceMade of galvanised steel 37, with 2 sets of installationaccessories, flanges PN 10/16, DIN 2501,DN 50/50/50 or 65/65/65TP 50 TP 65I 123 143J 123 143K 308 385165Pipe bend (Item 4)DIN 28637, nodular graphite iron(EN-GJS-400-15), with 1 set of installationaccessories for a flange connection. FlangesPN 10/16, to DIN 2501, DN 65 for TP 65 only165Installation accessories (Item 5)For a flange to flange connection, with 4 screws andnuts and 1 flat seal. Flanges PN 10/16, to DIN 2501,DN 65 for TP 65 only46 As of: 06/2004 - Subject to change without prior notice


Wastewater/DrainageWilo-Drain TP 50, TP 65Mechanical AccessoriesPortable wet sump installation TP 50 and 6561515141213250 2530025300Base plate (Item 9)For TP 65, made of galvanised steel, consisting of:1 base plate and mounting hardware (base plateprevents pump from sinking when set on sludgyground)Chain (Item 6)Made of galvanised steel, including stainless steelshackles, length: 5m, lifting capacity: 250kg.Submersible pumps4114119Rp 2BCADCounter flange (Item 11)Made of galvanised steel, incl. installation accessoriesDN 50 on Rp 2 female thread (TP 50)DN 65 on Rp 2 1 / 2 female thread (TP 65)Pipe bend (Item 4)Made of galvanised steel, with male/female threadR/G 2 or 2 1 / 2TP 50 TP 65A 130 165B G 2 G 21/2C 140 176D R 2 R 2 1 / 2EFØ GHose connection (Item 12)Direct connection for hose, including hose clipTP 50 TP 65E G 2 G 2 1 / 2F 90 100G 60 706637ØG 21/2Storz fixed coupling (Item 13)Made of aluminium, cam distance 66 mm, malethread R 2 (TP 50)Male thread G 2 1 / 2 (TP 65)66Ø 4590Ø 52Storz hose coupling (Item 14)Made of aluminium, to DIN 14321,Storz 52-C for hose inner diameter 52 mm,incl. hose clip, cam distance 66 mmcan be wound upPressure hose (Item 15)TP 50: Made of synthetic material, PN 6, hose innerdiameter 52/60 mm, length: 10mTP 65: Made of synthetic material, PN 8, manufacturedto DIN 14811, hose inner diameter 70 mm,For Item 12, length: 10 m or:Pressure hose for Storz hose coupling, made ofsynthetic material, PN 8, incl. hose clip, for Storz52-C connection, hose inner diameter 52 mm,length: 10 mHKIDN 50/65Pipe bend (Item 16)for hose connection including installation accessoriesfor direct connectionTP 50 TP 65H 60 70HI 188 170K 110 75DN 50: PlasticDN 65: Cast iron 25 (EN-GJL-250)As of: 06/2004 - Subject to change without prior notice47


Hot WaterWilo-Drain TMT/TMC, VCProduct DescriptionWilo-Drain TMT/TMCSubmersible wastewater pumpsType keyExample: Wilo-Drain TMC 30-0.5TM Submersible pumpT For hot domestic wastewater up to 95 °CC For industrial wastewater up to 95 °C30 Nominal diameter of delivery connection (DN 32)-0.5 Rated motor power [kW]ApplicationsSpecially constructed submersible pump for municipal and domesticuse to handle e.g. condensate, hot water and aggressive media.DesignOil-immersed, leak-proof encapsulated, noiseless three-phasesquirrel-cage motor, free of radio frequency interference. A faultcurrent safety switch (mandatory for outdoor installations) for abreaking current of 30 mA must be fitted by the customer, in accordancewith EN 60335-2, 41.Scope of deliveryPump with permanently connected supply line with bare cable endand installation and operating manual. (Motor protection onsite byothers).Hot WaterWilo-Drain TMT/TMC, VCProduct DescriptionWilo-Drain VCVertical wastewater pumpType keyExample: Wilo-Drain VC 32/10VC Vertical wastewater pump32 Nominal diameter of discharge port [mm]/10 Max. delivery head [m]ApplicationsWilo-Drain VC pumps are ideal for conveying wastewater that containssolid matter with a maximum diameter of 5 mm or 7 mm(VC 40). They have been specifically designed for conveying mediaup to 100 °C (e.g. condensate, pump sumps of boiler plants, basementsat risk of flooding).Suitable for installation:– On completely level ground– With shaft always vertical– VC 40 suspended from flangeDesignFloat switchVC 32: Built into motorVC 40: Separated from motorElectrical dataVC 32: 1~230 V with 40 µF capacitorVC 40: 3~230/400 V motor protection switch required on site.Scope of deliveryPump with attached float switch and installation and operatingmanual.48 As of: 06/2004 - Subject to change without prior notice


Hot WaterWilo-Drain TMT/TMC, VCPump Equipment/FunctionPump Equipment/FunctionWilo-DrainTMT/TMCWilo-DrainVC 32/40Operating mode: Intermittent service S3Frequency switching/h [%] 25 25Max. frequency switching/h 50 20Recommended frequency switching/h 20 20Operating mode: Continuous service S1Motor below water • –Motor air-cooled –Pump/motor seals•(2 hours/day)In pumping medium area: Mechanical seal • –On the motor compartment side: Shaft seal • –Oil seal chamber • –DesignWet sump installation Stationary • • (pump only)Portable • –Dry sump installation Stationary – –Submersible• •(pump housing only)Open multi-vane impeller • •MaterialsMotor Cast aluminium – •Stainless steel • –Bronze • –Cast iron • –Pump cast iron • •EquipmentBronze • –Power cable [m] 5 –Attached float switch – •Capacitor box – •Submersible pumps• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice49


Technical DataTMT 30-0.5Cast ironApproved fluids• = available or authorised, – = not available or not authorised1)above waterHot WaterWilo-Drain TMT/TMC, VCTechnical DataWilo-Drain TMT/TMC... Wilo Drain VC ...TMC 30-0.5BronzeTMC 30-0.7Stainless steelVC 32/10 VC 40/20Heating water • • • • •Hot water • • • • •Boiler feed water • • • • •Pump sumps of boiler plants • • • • •Condensate • • • • •Drainage water • • • • •Rainwater • • • • •Salt water – • – – –Wastewater, flood and river water • • • • •Highly dilute alkalines • – – – –Strong alkalines – • – – –Media with low aggressiveness • – – – –Acidic water – – • – –Aggressive media – • • – –PerformanceRated motor power P 2 [kW] 0.55 0.55 0.75 0.37 2.20Rated current for 1~230 V [A] – – – 3.65 –Rated current for 3~400 V [A] 1.9 1.9 1.9 0.88 4.40Rated current for 3~230 V [A] – – – 1.59 7.60Speed [rpm] 2,870 2,870 2,870 2,900 2,900MotorProtection class IP 68 IP 68 IP 68 IP 54 IP 54Insulation class H H H F FPumpSubmersion depth, max. [m] 5 5 5 – –Fluid temperature, max. [°C] 95/65 1) 95/65 1) 95/65 1) + 5 up to + 100Solid matter grain size [mm] 10 10 10 5 7Cable type SiAF SiAF SiAF – –Cable length [m] 5 5 5 – –Cable cross-section 3~400 V [mm 2 ] 4x 1.5 4x 1.5 4x 1.5 – –Type of power cable solid – –Activation type direct directDimensionsDischarge port DN/Rp 1 1 / 4 1 1 / 4 1 1 / 2 1 1 1 / 2Weight [kg] 30 33 32 36 75MaterialsPump housing EN-GJL-250 G-CuSn 10 1.4408 Cast ironImpeller EN-GJL-250 G-CuSn 10 1.4408 1.4028 EN-GJL-250Shaft 1.4122 1.4122 1.4571 Stainless steelBase plate – – – EN-GJL-250Lower sliding bearing – – – G-CuSn 10Intake sieve – – – Noryl (GFN 3)Float – – – PolypropyleneMechanical sealDouble, carbon/ceramicSingle, carbon/ceramic– –Static seals FPM PTFE/Teflon – –Motor housing EN-GJL-250 G-Cu SN 10 1.4402 Aluminium50 As of: 06/2004 - Subject to change without prior notice


Hot WaterWilo-Drain TMT/TMCPump Curves, Dimension Drawing, Dimensions, WeightsTMT/TMCWilo-Drain TMT/TMCPump Curves, Dimension Drawing, Dimensions, Weights2-pole, 50 Hz[m]12108Wilo-DrainTMT/TMC1 = TMT/TMC 30-0.52 = TMC 30-0.7Submersible pumpsH6242100 4 8 12 16[m 3 /h]0 1,0 2,0 3,0 4,0 5,0 [l/s]QDimension drawingDimensions, weightsDischarge port Height Pump diameter Weight– L 1 L 2 D –Rp [mm] [kg]Wilo-Drain TMT 30-0.5 cast iron 1 1 / 4 455 388 183 30Wilo-Drain TMC 30-0.5 bronze 1 1 / 4 455 388 183 33Wilo-Drain TMC 30-0.7 stainless steel 1 1 / 2 466 392 200 32As of: 06/2004 - Subject to change without prior notice51


Hot WaterWilo-Drain VC 32, VC 40Pump Curves, Dimension Drawing, DimensionsVC2-pole, 50 Hz[m]201816Wilo-Drain VCWilo-Drain VC 32, VC 40Pump Curves, Dimension Drawing, Dimensions1 = VC 32/102 = VC 40/2014H121082642100 2 4 6 8 10 12 14 16 [m 3 /h]QDimension drawingDimensionsDischargeportDimensions– H P H1 Ø D h1 h2 h3 P1Rp[mm]Wilo-Drain VC 32/10 1 1,240 300 1,020 230 160 610 250 141Wilo-Drain VC 40/20 1 1 / 2 1,400 458 1,034 325 130 740 130 19052 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 SProduct DescriptionWilo-Drain TP 40 S/25, TP 40 SSubmersible sewage pump with macerator, 2-poleType keyExample: Wilo-Drain TP 40 S 25TP Submersible pump40 Nominal diameter [mm]S Impeller type S = Macerator25 Max. delivery head [m]ApplicationsWilo-Drain TP 40 S submersible sewage pumps with macerator areideal for conveying household sewage including faeces. The Wilomacerator disintegrates the solid contents to particle sizes smallenough to pass through the pump impeller. Preferred application isthe pressurised waste disposal which is applied in such cases wherecosts for the conventional gravity sewage displacement becomeunjustifiably high, such as the following situations:– high ground water levels– insufficient ground gradients– intermittent generation of sewage– holiday home, camping grounds etc.Because of the low line diameter, e.g. DN 40, the installation costsare reduced dramatically.Suitable for:– Stationary wet sump installation– PortableDesignMonobloc submersible sewage pump with macerator for vertical wetsump installation.– Novel patented macerator– Free flow to the impeller– Inside rotating cutting– Conically designed macerator– Disintegrating particles– Drawing cutting actionMotorThree-phase asynchronous motor 3~400 V, 50 Hz or AC motor1~230 V, 50 Hz each with protection class IP 68, protected by thermalwinding contacts, insulation class F. Stainless steel motor designfor TP 40 S/25.BearingsThe motor shaft is bedded in permanently lubricated roller bearings.Shaft sealTP 40 S:Mechanical seal bidirectional and shaft seal on the pump side andmotor side. Oil-filled intermediate chamber for cooling and lubrication.TP 40 S/25:Bidirectional mechanical seal on the motor side, shaft seal on thepump side. Oil-filled intermediate chamber for cooling and lubrication.Hydraulic dataClosed single-vane impeller (with a free ball passage of 10 mm) inconjunction with a patented macerator ensures non-clogging pumpingand maximum efficiency.Scope of deliveryFully assembled pump with 10 m power cable and bare cable end at3~400 V; 10 m power cable and switch box (terminal strip) at1~230 V.Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 SProduct DescriptionSubmersible pumpsAs of: 06/2004 - Subject to change without prior notice53


Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 SPump Equipment/FunctionPump Equipment/FunctionWilo-Drain TP40 S/25 Wilo-Drain TP 40 SOperating mode S3 (intermittent service)Frequency switching/h [%] 25 25Max. frequency switching/h 50 50Recommended frequency switching/h 20 20Operating mode S1 (continuous service)Motor below water • •Pump/motor sealsIn pumping medium area: Mechanical seal • •On the motor compartment side: Mechanical seal – •• = available, – = not availableShaft seal • –Oil seal chamber • •DesignWet sump installation Stationary • •Portable • •Submersible • •Closed single-vane impeller • •Macerator • •MaterialsMotor Stainless steel • –Cast iron – •Pump Cast iron • •EquipmentMotor monitor (temperature) • •Power cable [m] 10 10Detachable power cable • •Capacitor box•(1~230 V model only)•(1~230 V model only)54 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 STechnical DataWilo-Drain TP ...Technical DataApproved fluidsTP 40 S/25Domestic wastewater and sewage including faeces • • • • • • •PerformancePower consumption P 1 1~230 V [kW] 2.0 – 2.0 – – – –TP 40 ...S 120/11TP 40 ...S 128/13TP 40 ...S 135/15TP 40 ...S 154/22TP 40 ...S 160/26TP 40 ...S 164/28Submersible pumpsPower consumption P 1 3~400 V [kW] 2.0 1.3 1.7 1.7 2.6 3.2 3.5Rated motor power P 2 [kW] 1.5 1.0 1.3 1.4 2.1 2.5 2.8Rated current for 1~230 V [A] 10.6 – 9.5 – – – –Rated current for 3~400 V [A] 3.8 2.5 3.1 3.5 4.4 5.8 6.3MotorProtection class for max. submersion depth IP 68 IP 68 IP 68 IP 68 IP 68 IP 68 IP 68Insulation class F F F F F F FPumpFluid temperature, max. [°C] 35/40 35/40 35/40 35/40 35/40 35/40 35/40Cable type• = available or authorised, – = not available or not authorisedH07 RN-FCable length [m] 10 10 10 10 10 10 10Cable cross-section 1~230 V [mm 2 ] 1.5 – – – – – –Cable cross-section 3~400 V [mm 2 ] 1.0 7x 1.5 7x 1.5 7x 1.5 7x 1.5 7x 1.5 7x 1.5Type of power cableActivation typeExplosion protectionDimensionslongitudinal watertight/plugdirectEEx d ll B T4 (3~400 V only)Weight [kg] 30 49 54 53 59 60 60MaterialsPump housingImpellerEN-GJL-200EN-GJL-200Shaft 1.4435 1.4021 1.4021 1.4021 1.4021 1.4021 1.4021Pump side:Mechanical seal(bidirectional)SiC/SiCMotor side: Mechanical seal Carbon/ceramicShaft seal NBR – – – – – –Static seals NBR NBR NBR NBR NBR NBR NBRMotor housing 1.4301 EN-GJL-250Macerator 1.4528 1.4528 1.4528 1.4528 1.4528 1.4528 1.4528As of: 06/2004 - Subject to change without prior notice55


Sewage/FaecesWilo-Drain TP 40 S/25Pump Curve, Dimension Drawing, DimensionsTP 40 S/252-pole, 50 HzWilo-Drain TP 40 S/25Pump Curve, Dimension Drawing, Dimensions[m]24Wilo-DrainTP 40 S/252016H128400 2 4 6 8 10 12Q[m 3 /h]Dimension drawingsStationary wet sump installation/ +Ø 600d F JPortable wet sump installation+200 25070ABØ 26,9D E FabkEeK308(300-330)ODN 2HN GDN2CGLMHKDN 1DN 1TØ 1070/ +1000LDimensionsWilo-Drain TP 40 S/25A B1 C D E F G H I J K L M N O T DN 1 DN 2 a b d e k[mm]140 110 14 115 81 160 465 245 56 120 240 120 300 95 134 280 50 40 140 110 155 7 1456 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 40 SPump Curves, Terminal DiagramTP 40 SWilo-Drain TP 40 SPump Curves, Terminal Diagram2-pole, 50 Hz[m]363228Wilo-DrainTP 40 S1 = TP 40 S 120/112 = TP 40 S 128/133 = TP 40 S 135/154 = TP 40 S 154/225 = TP 40 S 160/26Submersible pumps246 = TP 40 S 164/28H2016All pump curves shown are based on a density ofρ = 1 kg/dm 312856441 2 30 0 2 4 6 8 10 12 14 16 18Q[m 3 /h]Terminal diagramConnectionTerminal connections– Cable type U V W PE T1 T2 DITP 40 S ... 1~230 V – 1 (L1) 2 (N) – 0 4 5 –TP 40 S ... 3~400 V 6x 1.5 2 1 2 3 0 4 5 –As of: 06/2004 - Subject to change without prior notice57


GISewage/FaecesWilo-Drain TP 40 SDimension Drawing, DimensionsDimension drawingsStationary wet sump installationPortable wet sump installationØ 600dFJ70Ø 26,9k200+250DEFeE310DN2abK(300-330)ODN2H 1N GABCTM≥ IHLØ 10T≥ 70/ +Ø 1000DimensionsDimension Drawing, DimensionsDimensionsA B C D E F G H I J K L M N O T H 1 DN 2 * a b d e k[mm]TP 40 S 120/11 140 110 14 115 81 163 400 245 53 170 235 120 235 120 168 340 220 40/50 140 110 155 7 14TP 40 S 128/13TP 40 S 135/15140 110 14 115 81 163 450 245 53 170 235 120 235 120 167 340 220 40/50 140 110 155 7 14TP 40 S 154/22TP 40 S 160/26TP 40 S 164/28140 110 14 115 81 170 435 245 53 170 250 120 235 120 165 340 220 40/50 140 110 155 7 14* DN 40: Portable wet sump installation/ DN 50 stationary wet sump installation58 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 SMechanical AccessoriesStationary wet sump installationTP 40 S/251163120140160225235Wilo-Drain TP 40 S/25, TP 40 SMechanical AccessoriesBase elbow TP 40 S (Item 1a)Made of cast iron 25 (EN-GJL-250), including pumpsupport, profile seal, accessories for installation andfastening to the ground, and guide pipe bracket,discharge connection DN 50The double pipe guide R 3 / 4 must be provided onsite.Submersible pumps6821065904321a300150Ø 2570150242Base elbow incl. cable guideTP 40 S/25 (Item 1b)Made of cast iron 25 (EN-GJL-250), including pumpsupport, profile seal, accessories for installation andfastening to the ground, and guide pipe bracket.Complete 7 m cable guide for 3.5 m installationdepth. For connection DN 50 or DN 65.Alternatively, on-site installation with Ø 1" guidepipe possible.Chain (Item 6)including stainless steel shackles,length: 5 and 10 mTP 40 S1203200Check valve body (Item 2)DN 50, cast iron 25 (EN-GJL-250), flangesPN 10/16, with unrestricted passage, cleaning portand ventilation device including installation accessories,draw. No. 53.4-309.46235Gate valve (Item 3)DN 50, cast iron 25 (EN-GJL-250) flanges PN 10/16,incl. installation accessories31502150150Pipe bend (Item 4)Nodular graphite iron (EN-GJS-400-15),DIN 28637, DN 50, flanges PN 10/16, incl. 1 set ofinstallation accessories.1b308123 123Y-piece (Item 8)Made of steel 37, with 2 sets of installation accessories,flanges PN 10/16, to DIN 2501, DN 50/50/50.As of: 06/2004 - Subject to change without prior notice59


Portable wet sump installationTP 40 S/25120Sewage/FaecesWilo-Drain TP 40 S/25, TP 40 SMechanical AccessoriesAdjusting support (Item 9)Made of steel, including mounting hardwareØ 3406Ø 3404R 2R 2Pipe bend (Item 4a)Nodular graphite iron (EN-GGS-400-15), toDIN 28637, R 29TP 40 S140140Pipe bend (Item 4)Nodular graphite iron (EN-GGS-400-15), toDIN 28637, R 40, flanges:PN 6, DIN 2531PN 10/16, DIN 2533, incl. 1 set of installationaccessories (TP 40/S 25)6Chain (Item 6)including stainless steel shackles,length: 5 m and 10 m, lifting capacity: 400 kg4960 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Product DescriptionSubmersible pumpsWilo-Drain STC 80/100Submersible sewage pumpType keyExample: Wilo-Drain STC 80 E 17.95/37.5STC Submersible pump80 Nominal diameter [mm]E Impeller type:E = Single-vane impellerM = Multi-vane impeller17 Max. delivery head when Q = 0 [m]95 Max. volume flow [m 3 /h]37.5 Performance rating P 2 [kW] = value/10 = 3.75 kWApplicationsWilo-Drain STC submersible pumps are ideal for pumping faeces,municipal and industrial sewage containing long-fibre particles in thefollowing areas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewage farm technology– Industrial and process engineeringDesignMonobloc submersible sewage pump for vertical wet sump installation.Scope of deliveryFully assembled pump with 15 m power cable with bare cable endand installation and operating manual. Non standard cable lengths onrequestWilo-Drain STC 80/100, STS 80/100, TP 80-150Product DescriptionWilo-Drain STSSubmersible sewage pumpType keyExample: Wilo-Drain STS 80 F 81.120/20STS Submersible pump80 Nominal diameter [mm]F Free-flow impeller81 Max. delivery head when Q = 0 [m]120 Max. volume flow [m 3 /h]20 Performance rating P 2 [kW] = value/10 = 2.0 kWApplicationsWilo-Drain STS submersible pumps are ideal for pumping faeces,municipal and industrial sewage containing long-fibre particles in thefollowing areas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewage farm technology– Industrial and process engineeringHigh operating reliability due to unrestricted free spherical passage.Suitable for:– Stationary wet sump installation– Portable wet sump installationDesignMonobloc submersible sewage pump for vertical wet sump installation.– Detachable power cable– Large free ball passage– Corrosion- and wear-resistantMotorThree-phase asynchronous motor 3~400 V, 50 Hz, protection classIP 68, thermal winding contacts. Insulation class F Other operatingvoltages and frequencies upon request.BearingsThe motor shaft is bedded in permanently lubricated, low-maintenanceroller bearings.Shaft sealMechanical seal on the motor side and shaft seal on the pump side.Scope of deliveryFully assembled pump with 10 m power cable with bare cable endand installation and operating manual. Non standard cable lengths onrequestAs of: 06/2004 - Subject to change without prior notice61


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Product DescriptionMotorThree-phase asynchronous motor 3~400 V, 50 Hz, protection classIP 68, leak monitoring, thermal winding contacts. Insulation class F.Other operating voltages and frequencies upon request.Note:When connecting switchgear that is provided on-site, use the SK 545trigger device (see electrical accessories) for connecting the thermalwinding contacts (WSK) and leak monitoring (WSK connection is atmax. 30 V, max. 30 mA, follow the operating manual).BearingsThe motor shaft is bedded in permanently lubricated, low-maintenanceroller bearings.Wilo-Drain TP 80-150Submersible sewage pumpType keyExample: Wilo-Drain TP 100 E 210/52TP Submersible pump100 Nominal diameter [mm]E Impeller type:E = Single-vane impellerF = Free-flow impellerM = Multi-vane impeller210 Impeller nominal diameter [mm]/52 Performance rating P 2 [kW] = value/10 = 5.2 kWApplicationsWilo-Drain TP 80 up to 150 are ideal for pumping faeces, municipaland industrial sewage containing long-fibre particles in the followingareas:– Building and surface drainage– Sewage disposal and conservation– Environmental protection and sewage farm technology– Industrial and process engineeringHigh operating reliability due to unrestricted free spherical passage.Low weight, thus ideally suited for emergency situations. Suitablefor:– Stationary wet sump installation– Portable wet sump installation– Vertical dry sump installations (without explosion protection)– Horizontal dry sump installation upon requestMotor coolingContinuous, non-clogging forced-flow casing cooling with patentedreturn pipe.Shaft sealDouble, pump- and motor-end, bidirectional mechanical seals.Leak monitoringSignals the ingress of moisture into the motor compartment.Hydraulic dataStandard supply with patented spiral baseplate for choke-free continuousduty (single-vane impeller).TP 80: Single-vane impeller/free-flow impellerFree ball passage 80 mmTP 100: Single-vane impeller/free-flow impellerFree ball passage 80/95 mmTP 150: Single-vane impeller/free-flow impellerMulti-vaneimpellerFree ball passage Ø 100 mmScope of deliveryFully assembled pump with 10 m power cable with bare cable endand installation and operating manual. Non standard cable lengths onrequestDesignMonobloc submersible sewage pump for vertical wet or dry sumpinstallation.–Inox & Composite– Fitted as standard with explosion protection with thermal windingsystem (WSK) connected and completely submersed hydraulicsystem. Follow the instructions in the installation and operatingmanual.–Low weight– Leak monitoring– Forced-flow casing cooling– Detachable power cable– Large free ball passage– Corrosion and wear-resistant– Oil-free intermediate chamber62 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Pump Equipment/Function STC 80/100Pump Equipment/Function STC 80/100Wilo-Drain ...STC 80 E 17.95/37.5STC 80 E 24.65/37.5STC 80 E 24.95/50STC 80 E 31.55/50STC 80 F 33.65/105STC 80 F 33,120/155STC 80 F 38,100/155STC 80 F 45,100/155STC 80 F 51.70/155STC 100 E 19,180/65STC 100 E 24,200/100STC 100 E 28,150/100STC 100 M 40,190/250STC 100 M 50,140/250STC 100 M 60,165/340Operating mode S1 (continuous service)Motor below water • • • • • •Pump/motor sealsIn pumping medium area: Mechanical seal • • • • • •On the motor compartment side: Mechanical seal – – – – – •Shaft seal • • • • • –Oil seal chamber • • • • • •DesignWet sump installation Stationary • • • • • •Portable • • • • • •Submersible • • • • • •Closed single-vane impeller • • – – • –Closed multi-vane impeller – – – – – •Free-flow impeller – – • • – –MaterialsMotor Cast iron • • • • • •Pump Cast iron • • • • • •EquipmentMotor monitor (temperature) • • • • • •Power cable [m] (other lengths upon request) 15 15 15 15 15 15Submersible pumps• = available, – = not availableAs of: 06/2004 - Subject to change without prior notice63


Pump Equipment/Function STS 80/100• = available, – = not availableSewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Wilo-DrainSTS 80Pump Equipment/Function STS 80/100Wilo-DrainSTS 100Operating mode S3 (intermittent service)Frequency switching/h [%] 25 25Max. frequency switching/h 20 20Recommended frequency switching/h 20 20Operating mode S1 (continuous service)Motor below water • •Pump/motor sealsIn pumping medium area: Mechanical seal SiC/SiC SiC/SiCOn the motor compartment side: Shaft seal NBR NBROil seal chamber • •DesignWet sump installation Stationary • •Portable • •Submersible • •Free-flow impeller • •MaterialsMotor Stainless steel • •Pump Cast iron • •EquipmentMotor monitor (temperature) • •64 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Pump Equipment/Function TP 80-150Pump Equipment/Function TP 80-150Wilo-DrainTP 80Wilo-DrainTP 100Wilo-DrainTP 150Operating mode S3 (intermittent service)Frequency switching/h [%] 25 25 25Max. frequency switching/h 20 20 20Recommended frequency switching/h 20 20 20Operating mode S1 (continuous service)Motor below water and above water • • •Pump/motor sealsIn pumping medium area: Mechanical seal • • •On the motor compartment side: Mechanical seal • • •Oil seal chamber • • •DesignWet sump installation Stationary • • •Portable • • •Mobile•(available as a special modelupon request only)•(available as a special modelupon request only)•(available as a special modelupon request only)Dry sump installation Vertical • • •Horizontal•(available as a special modelupon request only)•(available as a special modelupon request only)•(available as a special modelupon request only)Submersible • • •Open single-vane impeller • • •Open multi-vane impeller • • •Free-flow impeller • • •Turbulator • • •Non-clogging cooling system • • •MaterialsMotor Stainless steel • • •Pump Plastic • • •EquipmentMotor monitor (temperature) • • •Motor monitor (leaks) • • •Explosion protection • • •Forced-flow casing cooling • • •Power cable [m] 10 10 10Detachable power cable • • •Attached float switch – – –Submersible pumps• = available, – = not availableAs of: 06/2004 - Subject to change without prior notice65


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data STC 80Technical Data STC 80Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systemsE 17.95/37.5E 24.65/37.5E 24.95/50E 31.55/50Wilo-Drain STC 80...Heating water • (up to 40 °C)Hot water • (up to 40 °C)Boiler feed water • (up to 40 °C)Condensate • (up to 40 °C)Cooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterRainwaterSwimming pool waterSea waterWastewater, flood and river waterDomestic wastewater and sewage including faecesFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)Highly dilute alkalinesStrong alkalinesMedia with low aggressivenessAcidic waterAggressive mediaPerformanceF 33.65/105••••••••••ConditionallyConditionally•••Gaseous: conditionally, otherwise • (Impeller E up to 8%, F up to 10%)•Conditionally•ConditionallyConditionallyPower consumption P 1 3~400 V [kW] 4.7 4.7 6.0 6.0 12.3 18.6 18.6 18.6 18.6Rated motor power P 2 [kW] 3.75 3.75 5.0 5.0 10.5 15.5 15.5 15.5 15.5Rated current for 3~400 V [A] 7.6 7.6 9.7 9.7 20.5 30.5 30.5 30.5 30.5MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 15FF 33.120/155F 38.100/155F 45.100/155F 51.70/15566 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data STC 80Wilo-Drain STC 80...Technical Data STC 80PumpSubmersion depth, max. [m] 12.5Fluid temperature [°C] 40Fluid temperature permissible for short periods [°C] 60Fluid density, max. [kg/m 3 ] 1050Cable typeH07 RN-F, roundCable length [m] 15Cable cross-section 3~400 V [mm 2 ] 7G1.5 10G1.5Type of power cableRubber sheathed cableActivation type direct Star-deltaPower supply: NSSHÖU-JControl line: NSSHÖU-OPower supply: 7x2.5Control line: 2x1.5Oil volume of seal housing [l] 0.55 0.55 0.55 0.55 2 3.3 3.3 3.3 3.3Free ball passage [mm] 70 70 70 70 80 80 80 50 50DimensionsDischarge port DN 80 80 80 80 80 80 80 80 80Weight [kg] 55 55.5 59 59.5 119 163 163.5 162 162MaterialsPump housingEN-GJL-200Impeller EN-GJS-500-7 EN-GJL-200 EN-GJS-500-7Shaft 1.4021Mechanical seal (bidirectional), pump sideStatic sealsSiC/SiCFPM/NBRShaft seal on motor side FPM NBRMotor housingE 17.95/37.5E 24.65/37.5E 24.95/50E 31.55/50F 33.65/105EN-GJL-200F 33.120/155F 38.100/155F 45.100/155F 51.70/155Submersible pumps• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice67


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data STC 100Technical Data STC 100Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systemsE 19.180/65E 24.200/100Wilo-Drain STC 100...Heating water • (up to 40 °C)Hot water • (up to 40 °C)Boiler feed water • (up to 40 °C)Condensate • (up to 40 °C)Cooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterRainwaterSwimming pool waterSea waterWastewater, flood and river waterDomestic wastewater and sewage including faecesFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)Highly dilute alkalinesStrong alkalinesMedia with low aggressivenessAcidic waterAggressive mediaPerformanceE 28.150/100••••••••••ConditionallyConditionally•••M 40.190/250Gaseous: conditionally, otherwise •(Impeller E up to 8%, F up to 10%)•Conditionally•ConditionallyConditionallyPower consumption P 1 3~400 V [kW] 8.2 12.2 12.2 28.5 28.5 39.0Rated motor power P 2 [kW] 6.5 10.0 10.0 25.0 25.0 34.0Rated current for 3~400 V [A] 13.5 21.0 21.0 49.5 49.5 68MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 15FM 50.140/250M 60.165/34068 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data STC 100Wilo-Drain STC 100...Technical Data STC 100PumpSubmersion depth, max. [m] 12.5Fluid temperature [°C] 40Fluid temperature permissible for short periods [°C] 60Fluid density, max. [kg/m 3 ] 1,050Cable typeH07 RN-F, roundCable length [m] 15Cable cross-section 3~400 V [mm 2 ] 10G1.5Type of power cableActivation typeRubber sheathed cableStar-deltaPower supply: NSSHÖU-JControl line: NSSHÖU-OPower supply: 2x(4x4)Control line: 2x1.5Powersupply: 7x2.5Control line:2x1.5Oil volume of seal housing [l] 2 2 2 8.6 8.6 8.6Free ball passage [mm] 80 80 80 80 80 80DimensionsDischarge port DN 100 100 100 100 100 100Weight [kg] 106 137 139 361 376 415MaterialsPump housing EN-GJL-250 EN-GJS-500-7Impeller EN-GJL-250 EN-GJS-500-7Shaft 1.4021Mechanical seal (bidirectional), pump side SiC/SiC Cartridge: SiC/SiC, housing: 1.4021Mechanical seal (bidirectional), motor side – Cartridge: SiC/SiC, housing: 1.4021Static sealsE 19.180/65FPM/NBRShaft seal on motor side FPM –Motor housing EN-GJL-250 EN-GJL-250E 24.200/100E 28.150/100M 40.190/250M 50.140/250M 60.165/340Submersible pumps• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice69


Technical Data STS 80/100Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systemsF 7.110/20Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150F 9.120/24Wilo-Drain ...Technical Data STS 80/100STS 80 STS 100Heating water • (up to 40 °C)Hot water • (up to 40 °C)Water from boilers • (up to 40 °C)Condensate • (up to 40 °C)Cooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterRainwaterSwimming pool water –Sea water –Wastewater, flood and river waterDomestic wastewater and sewage including faecesFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)Highly dilute alkalinesStrong alkalinesMedia with low aggressivenessAcidic waterAggressive mediaPerformanceF 10.120/27F 12.120/32•••••••••••••F 14.100/40F 10.170/59Gaseous: conditionally, otherwise • (up to 10%)•Conditionally•ConditionallyConditionallyPower consumption P 1 3~400 V [kW] 2.7 3.4 3.7 4.5 5.3 7.1 8.8 10.1Motor power P 2 [kW] 2.0 2.4 2.7 3.2 4.0 5.9 7.2 8.4Rated current for 3~400 V [A] 6.1 6.7 7.0 8.0 8.9 14.2 16.5 18.5Speed [rpm] 1,450MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 20FF 12.170/72F 15.170/8470 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data STS 80/100Wilo-Drain ...Technical Data STS 80/100STS 80 STS 100F 7.110/20F 9.120/24F 10.120/27F 12.120/32F 14.100/40F 10.170/59F 12.170/72F 15.170/84PumpSubmersion depth, max. [m] 10Fluid temperature [°C] 40Fluid temperature permissible for short periods [°C] 60Fluid density, max. [kg/m 3 ] 1050Cable typeH07 RN-F, roundCable length [m] 10Cable cross-section 3~400 V [mm 2 ] 7xG 1.5 strand 6 not occupied 10xG 1.5 strand 9 not occupiedPlug CONI Strands with flat plugType of power cableOZOFLEX Plus (H07 RN-F)Activation type direct Star-deltaOil volume of oil chamber [l] 0.17 0.35Free ball passage [mm] 75 100DimensionsDischarge port DN 80 100Weight [kg] 70 96MaterialsPump housingEN-GJL-250ImpellerEN-GJL-250Shaft 1.4021Mechanical seal (bidirectional), pump sideSiC/SiCStatic sealsNBRShaft seal on motor sideNBRMotor housing 1.4404Submersible pumps• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice71


Technical Data TP 80Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systems• = available or authorised, – = not available or not authorisedE 160/14E 170/18Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150E 190/26E 210/34Wilo-Drain TP 80...Heating water, boiler feed water • (up to 40 °C)Condensate • (up to 40 °C)Cooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterRainwaterSwimming pool waterSea waterWastewater, flood and river waterFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)PerformanceE 230/34••••••••••••F 155/20F 165/24Technical Data TP 80Power consumption P 1 3~400 V [kW] 1.9 2.3 3.4 4.6 4.6 2.7 3.4 3.7 4.5 4.8Rated motor power P 2 [kW] 1.4 1.8 2.6 3.4 3.4 2.0 2.4 2.7 3.2 3.4Rated current for 3~400 V [A] 4.5 5.1 6.4 8.0 8.0 6.1 6.7 7.0 8.0 8.4MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 60PumpFluid temperature [°C] 40Cable typeCable length [m] 10•••FNSSHöuCable cross-section 3~400 V [mm 2 ] 7x1.5Type of power cableActivation typeExplosion protectionlongitudinal watertight/terminal stripdirectEEx d ll B T4Free ball passage [mm] 78DimensionsWeight [kg] 42 43MaterialsPump housingImpellerPolyurethanePolyurethaneShaft 1.0570/1.4404Mechanical seal (bidirectional), pump sideMechanical seal (bidirectional), motor sideSiC-SiCMotor housing 1.4404C-CrF 180/27F 190/32F 210/3472 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data TP 100Wilo-Drain TP 100 ...Technical Data TP 100Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systemsHeating water, boiler feed water • (up to 40 °C)Condensate • (up to 40 °C)Cooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterSwimming pool waterSea waterWastewater, flood and river waterFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)PerformanceE 160/14E 180/22Power consumption P 1 3~400 V [kW] 1.9 2.7 4.0 4.6 4.4 6.2 8.4 10.0 2.5 3.1 3.5Rated motor power P 2 [kW] 1.4 2.2 3.0 3.4 3.9 5.2 7.0 8.4 1.8 2.2 2.5Rated current for 3~400 V [A] 4.4 5.5 7.5 8.5 10.5 12.8 15.6 18.1 5.0 5.6 6.1MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [per hour] 60PumpFluid temperature, max. [°C] 40Cable typeCable length [m] 10E 210/30E 230/34E 190/39E 210/52••••••••••••••FNSSHöuCable cross-section 3~400 V [mm 2 ] 7x1.5 10x1.5 7x1.5Type of power cablelongitudinal watertight/terminal stripE 230/70E 250/84longitudinal watertight/plugF 155/18F 165/22F 180/25longitudinal watertight/terminal stripActivation type direct direct or star-delta directExplosion protection EEx de ll B T4 EEx d ll B T4Free ball passage [mm] 78 95 78DimensionsWeight [kg] 43 60 43MaterialsPump housingPolyurethaneImpellerPolyurethaneShaft 1.0570/1.4404Mechanical seal (bidirectional), pump sideMechanical seal (bidirectional), motor sideSiC – SiCC – CrMotor housing 1.4404Submersible pumps• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice73


Technical Data TP 100, TP 150Approved fluidsWashing machine soap and water mixture(without long-fibre particles)Water from car wash facilitiesNon-chlorinated pool waterWater from firefighting systems• = available or authorised, – = not available or not authorisedF 180/31F 210/34Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Technical Data TP 100, TP 150Wilo-Drain TP 100 ... Wilo-Drain TP 150 ...Heating water, boiler feed water • (up to 40 °C)CondensateCooling (condenser) waterClean waterUntreated wastewaterDrainage waterPartially desalinated waterSwimming pool waterSea waterWastewater, flood and river waterFaeces, municipal and industrial sewage containing longfibreparticlesGaseous and non-gaseous sludge (up to 10% by volumeof dry substance)PerformanceF 195/59F 220/72F 247/84••••M 235/130• (up to 40 °C)Power consumption P 1 3~400 V [kW] 4.3 4.7 7.1 8.8 10.1 15.4 19.6 23.9 12.6 17.5Rated motor power P 2 [kW] 3.1 3.4 5.9 7.2 8.4 12 16.5 20 10.8 14.8Rated current for 3~400 V [A] 7.1 8.0 14.2 16.5 18.5 28.9 34 41.6 27.6 34.7MotorProtection class for max. submersion depth IP 68Insulation classFrequency switching [1/h] 60PumpFluid temperature, max. [°C] 40 40Cable type NSSHöu NSSHöuCable length [m] 10 10Cable cross-section 3~400 V [mm 2 ] 7x1.5 10x1.5 7x4 + 5x1.5Type of power cablelongitudinalwatertight/terminal striplongitudinal watertight/plug••••••••••FM 250/165M 265/200E 280/110longitudinal watertight/plugActivation type direct direct or star-delta Star-deltaExplosion protection EEx d ll B T4 EEx d ll B T4 EEx d ll B T4Free ball passage [mm] 78 95 125DimensionsWeight [kg] 43 60 112MaterialsPump housing Polyurethane PolyurethaneImpeller Polyurethane PolyurethaneShaft 1.0570/1.4404 1.0570/1.4404Mechanical seal (bidirectional), pump side SiC – SiC SiC – SiCMechanical seal (bidirectional), motor side C – Cr C – CrMotor housing 1.4404 1.4404E 295/15074 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STC 80/100Pump CurvesSTC 80EWilo-Drain STC 80/100Pump Curves2-pole, 50 HzH[m]32282624222018161412108642[[[421]Wilo-DrainSTC 80 E31 = STC 80E 17.95/37.52 = STC 80E 24.65/37.53 = STC 80E 24.95/504 = STC 80E 31.55/50[ = Q min] = Q max for pump curve 2Submersible pumpsP 2 [W]0 00020 40 60 80 100 120 [m 3 /h]5 10 15 20 25 30 35 [l/s]100 200 300 400 [lgpm]Q65442 3312100 20 40 60 80 100 120 [m 3 /h]QSTC 80F2-pole, 50 Hz[m]5550Wilo-DrainSTC 80F5 = STC 80F 33.65/1056 = STC 80F 33.120/1557 = STC 80F 38.100/15545H4035302520[[5]7[ = Q min] = Q max for pump curve 51561050 0 20 40 60 80 100 120 140 [m 3 /h]0 10 20 30 40 [l/s]0 100 200 300 400 500 [lgpm]Q252015756P 2 [W]10500 20 40 60 80 100 120 140 [m 3 /h]QAs of: 06/2004 - Subject to change without prior notice75


Sewage/FaecesWilo-Drain STC 80/100Pump CurvesSTC 80F2-pole, 50 Hz[m]5550Wilo-DrainSTC 80F8 = STC 80F 45,100/1559 = STC 80F 51.70/15545I = Q min40H3530925201581050 0 20 40 60 80 100 120 140 [m 3 /h]0 10 20 30 40 [l/s]0 100 200 300 400 500 [lgpm]Q25P 2 [W]20151098500 20 40 60 80 100 120 140 [m 3 /h]QSTC 100E/M4-pole, 50 HzH[m]706050405Wilo-DrainSTC 100E/M61 = STC 100E 19.180/652 = STC 100E 24.200/1003 = STC 100E 28.150/1004 = STC 100M 40.190/2505 = STC 100M 50.140/2506 = STC 100M 60.165/340I = Q min304P 2 [W]2010100 20 40 60 80 100 120 140 160 180 200 220 [m 3 /h]0 10 20 30 40 50 60 [l/s]0 100 200 300 400 500 600 700 800 [lgpm]Q3663052441812600 20 40 60 80 100 120 140 160 180 200 220 [m 3 /h]Q3312276 As of: 06/2004 - Subject to change without prior notice


ISewage/FaecesWilo-Drain STC 80/100Dimension Drawings, DimensionsDimension drawingsDimension Drawings, DimensionsStationary wet sump installation – STC 80 Stationary wet sump installation – STC 80H min.FDN 32ABH min.Submersible pumpsEDCDN80ORPNLMJH1GØ KUH2DN 80GDN 80QTDimensionsDimensionsA B C D E F G H1 H2 I J Ø K L M N O P Q R[mm]STC 80 E 17.95 ... 200 160 18 166 59 90 539 580 580 119 124 344 210 300 15 120 170 264 229STC 80 E 24.65 ... 200 160 18 166 59 90 539 580 580 119 124 344 210 300 15 120 170 264 229STC 80 E 24.95 ... 200 160 18 166 59 90 594 635 635 119 124 344 210 300 15 120 170 264 229STC 80 E 31.55 ... 200 160 18 166 59 90 594 635 635 119 124 344 210 300 15 120 170 264 229STC 80 F 33.65 ... 200 160 18 166 59 90 753 790 805 110 124 344 210 300 15 120 170 374 340STC 80 F 33.120 ... 200 160 18 166 59 90 875 910 925 110 124 344 210 300 15 120 170 374 340STC 80 F 38.100 ... 200 160 18 166 59 90 875 910 925 110 124 344 210 300 15 120 170 374 340STC 80 F 45.100 ... 200 160 18 166 59 90 832 880 875 125 124 344 210 300 15 120 170 405 350STC 80 F 51.70 ... 200 160 18 166 59 90 832 880 875 125 124 344 210 300 15 120 170 405 350As of: 06/2004 - Subject to change without prior notice77


ISewage/FaecesWilo-Drain STC 80/100Dimension Drawings, DimensionsDimension drawingsStationary wet sump installation – STC 100 Stationary wet sump installation – STC 100FABDNCGEDDN100GH1DN100H2OPDN 100JLNMØ KR19171DN 100Q220140280340S42050050RDimensionsDimensionsA B C D E F G H1 H2 I J Ø K L M N O P Q R[mm]STC 100 E 19.180 ... 220 180 18 176 65 90 664 710 715 120 124 320 225 325 15 160 190 448 394STC 100 E 24.200 ... 220 180 18 176 65 90 744 670 795 120 124 320 225 325 15 160 190 448 394STC 100 E 28.150 ... 220 180 18 176 65 90 744 670 795 120 124 320 225 325 15 160 190 448 394STC 100 M 40.190 ... 220 180 18 241 109 120 1160 1160 1155 183 180 500 320 540635 563STC 100 M 50.140 ... 220 180 18 241 109 120 1160 1160 1155 183 180 500 320 540 on request 635 563STC 100 M 60.165 ... 220 180 18 241 109 120 1230 1230 1225 183 180 500 320 540 635 56378 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain STS 80/100Pump CurvesSTS 80 F4-pole, 50 HzH[m]14121086454321xxxxxWilo-DrainSTS 80 F1 = STS 80 F 7.110/202 = STS 80 F 9.120 /243 = STS 80 F 10.120/274 = STS 80 F 12.120/325 = STS 80 F 14.100/40All pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimalSubmersible pumps20 0 20 40 60 80 100 [m 3 /h]0 5 10 15 20 25 30 [l/s]0 100 200 300[lgpm]Q4Recommended:Q optimal +10% / -20%P 2 [W]3215314200 20 40 60 80 100 [m 3 /h]QWilo-Drain STS 80/100Pump CurvesSTS 100 F4-pole, 50 Hz[m]2220181614Wilo-DrainSTS 100F1 = STS 100 F 10.170/592 = STS 100 F 12.170/723 = STS 100 F 15.170/84All pump curves shown are based on a density of ρ = 1 kg/dm 3H1210864xxx32I = Q minX = Q optimalRecommended:Q optimal +10% / -20%21P 2 [W]0 0 20 40 60 80 100 120 140 160 [m 3 /h]0 10 20 30 40 50 [l/s]0 100 200 300 400 500 600 [lgpm]Q10832614200 20 40 60 80 100 120 140 160 [m 3 /h]QAs of: 06/2004 - Subject to change without prior notice79


Terminal diagram Wilo-Drain STS 80Sewage/FaecesWilo-Drain STS 80/100Terminal DiagramsTerminal U 1 V 1 W 1 WSK WSK PEWire No. 1 2 3 4 5 green/yellow3~400 V, 50 HzTerminal diagram Wilo-Drain STS 100Terminal U 1 V 1 W 1 V 2 W 2 U 2 WSK WSK PEWire No. 1 2 3 4 5 6 7 8 03~400 V, 50 HzTerminal Diagrams80 As of: 06/2004 - Subject to change without prior notice


ISewage/FaecesWilo-Drain STS 80/100Dimension Drawings, DimensionsDimension drawings STS 80Dimension Drawings, DimensionsStationary wet sump installation15409060142 x Ø 42,4 x 3,25)DIN 2440+Ø 650 700 x 1200abkdeE52FJkcSubmersible pumps+300 325DEF615(550 - 750)ABDN2CMHGDN185L12Ø 1200 Ø 1500+Portable wet sump installationmin80DN2H1GØ 195300ODN1N230,5380,5TKDimensionsWilo-Drain STS 80[mm]DN 1 DN 2 A B C D E F G H I J K80 80 200 160 19 146 81 228 660 300 70 185 355L M a b c d e k H 1 H N O T180 315 200 170 170 220 14 14 635 85 200 409As of: 06/2004 - Subject to change without prior notice81


ISewage/FaecesWilo-Drain STS 80/100Dimension Drawings, DimensionsDimension drawings STS 100Stationary wet sump installation8860+Ø 650 700 x 12004014802 x 1,5" (Ø 47,8 x 3,25)DIN 2440kdeEFJ300325+ABDEFabc68615(550 - 750)DN2kC*MGHDN1L85Ø 12DN 1+Ø 1200 Ø 1500Portable wet sump installationmin90DN2DN1TKH1GØ 220ON337,5260428DimensionsWilo-Drain STS 100[mm]DN 1 DN 2 A B C D E F G H I J K100 100 220 180 18 169 91 255 825 780 90 195 440L M a b c d e k H 1 N O T225 400 260 220 220 250 15 20 890 90 250 45082 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Pump CurvesTP 80 EWilo-Drain TP 80, TP 100, TP 150Pump Curves4-pole, 50 HzH[m]1614121085Wilo-DrainTP 80 E1 = TP 80 E 160/142 = TP 80 E 170/183 = TP 80 E 190/264 = TP 80 E 210/345 = TP 80 E 230/34All pump curves shown are based on a density of ρ = 1 kg/dm 3Submersible pumps64423120 0 20 40 60 80 100 120 140 [m 3 /h]0 10 20 30 40 [l/s]I = Q minX = Q optimalRecommended:Q optimal +10% / -20%43Q543P 2 [W]211200 20 40 60 80 100 120 140[m 3 /h]QTP 80 F4-pole, 50 HzH[m]14121086454321xxxxxWilo-DrainTP 80 F1 = TP 80 F 155/202 = TP 80 F 165/243 = TP 80 F 180/274 = TP 80 F 190/325 = TP 80 F 210/34All pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimal2Recommended:Q optimal +10% / -20%0 0 20 40 60 80 100 [m 3 /h]0 5 10 15 20 25 30 [l/s]0 100 200 300[lgpm]Q4P 2 [W]3215314200 20 40 60 80 100 [m 3 /h]QAs of: 06/2004 - Subject to change without prior notice83


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Pump CurvesTP 100 E4-pole, 50 Hz[m]1614Wilo-DrainTP 100 E1 = TP 100 E 160/142 = TP 100 E 180/223 = TP 100 E 210/304 = TP 100 E 230/34H121086424321xxxxAll pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimalRecommended:Q optimal +10% / -20%0 0 20 40 60 80 100 [m 3 /h]0 10 20 30 [l/s]P 2 [W]4321Q432100 20 40 60 80 100 [m 3 /h]QTP 100 E4-pole, 50 Hz[m]2016Wilo-DrainTP 100 E5 = TP 100 E 190/396 = TP 100 E 210/527 = TP 100 E 230/708 = TP 100 E 250/84P 2 [W] H12840 0 40 80 120 160 [m 3 /h]0 10 20 30 40 50 [l/s]864xQxxx55668778All pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimalRecommended:Q optimal +10% / -20%20 40 80 120 160 [m 3 /h]Q84 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Pump CurvesTP 100 F4-pole, 50 HzH[m]141210864xxxx xWilo-DrainTP 100F139 = TP 100 F 155/1810 = TP 100 F 165/2211 = TP 100 F 180/2512 = TP 100 F 180/3113 = TP 100 F 210/34All pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimalSubmersible pumpsP 2 [W]212911100 0 20 40 60 80 100 120 [m 3 /h]0 5 10 15 20 25 30 35 [l/s]0 100 200Q300 400 [lgpm]4133121129101Recommended:Q optimal +10% / -20%00 20 40 60 80 100 120 [m 3 /h]QTP 100 F4-pole, 50 Hz[m]2220Wilo-DrainTP 100F14 = TP 100 F 195/5915 = TP 100 F 220/7216 = TP 100 F 247/84181614All pump curves shown are based on a density of ρ = 1 kg/dm 3H1210864xxx1615I = Q minX = Q optimalRecommended:Q optimal +10% / -20%214P 2 [W]0 0 20 40 60 80 100 120 140 160 [m 3 /h]0 10 20 30 40 50 [l/s]0 100 200 300 400 500 600 [lgpm]Q10168156144200 20 40 60 80 100 120 140 160 [m 3 /h]QAs of: 06/2004 - Subject to change without prior notice85


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Pump CurvesTP 150 M4-pole, 50 Hz[m]2420Wilo-DrainTP 150M1 = TP 150 M 235/1302 = TP 150 M 250/1653 = TP 150 M 265/200H1612xxxAll pump curves shown are based on a density of ρ = 1 kg/dm 3I = Q minX = Q optimal84123Recommended:Q optimal +10% / -20%P 2 [W]0 080 160 240 320 [m 3 /h]0 10 20 30 40 50 60 70 80 90 100 [l/s]Q20321511050 80 160 240 320 [m 3 /h]QTP 150 E4-pole, 50 Hz[m]282420Wilo-DrainTP 150E4 = TP 150 E 280/1105 = TP 150 E 295/150All pump curves shown are based on a density of ρ = 1 kg/dm 3H16128xxI = Q minX = Q optimalRecommended:Q optimal +10% / -20%4450 080 160 240 320 [m 3 /h]0 10 20 30 40 50 60 70 80 90 100 110 [l/s]Q20155P 2 [W]105400 80 160 240 320 [m 3 /h]Q86 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Terminal DiagramsTerminal diagram Wilo-Drain TP 80 and TP 100 ( ≤ P 2 = 3.5 kW)Terminal U 1 V 1 W 1 WSK WSK/PE DI PEWire No. 1 2 3 4 5 6 green/yellow3~400 V, 50 HzTerminal diagram Wilo-Drain TP 100 ( > P 2 = 3.5 kW)Terminal U 1 V 1 W 1 V 2 W 2 U 2 WSK WSK/PE DI PEWire No. 1 2 3 4 5 6 7 8 9 03~400 V, 50 HzSubmersible pumpsTerminal diagram Wilo-Drain TP 150Terminal U 1 V 1 W 1 V 2 W 2 U 2 PE WSK WSK/PE DI – –Wire No. 1 2 3 4 5 6 0 1 2 3 4 53~400 V, 50 HzTerminal DiagramsAs of: 06/2004 - Subject to change without prior notice87


ISewage/FaecesWilo-Drain TP 80, TP 100, TP 150Dimension Drawings, DimensionsDimension drawings TP 80Stationary wet sump installation9060+Ø 650 700 x 1200kdeEFJ154014k2 x Ø 42,4 x 3,25DIN 2440abc52300 325+DEF615(550 - 750)ABDN2CMHGDN1LDN18512Portable wet sump installation+Ø 1200 Ø 1500Dimension Drawings, DimensionsVertical dry sump installationVhGf225DN 2ODN1H 1N GTUminPSQ>85R225264494DimensionsWilo-Drain TP 80[mm]DN 1 DN 2 A B C D E F G H I J K L M a b c d e kTP 80 F 80 80 200 160 19 146 81 228 725 300 80 200 428 185 315 200 170 170 220 14 14TP 80 E 100 80 200 160 19 146 81 228 725 300 80 200 428 185 315 200 170 170 220 14 1488 As of: 06/2004 - Subject to change without prior notice


ISewage/FaecesWilo-Drain TP 80, TP 100, TP 150Dimension Drawings, DimensionsDimension drawings TP 100Stationary wet sump installation4014708880+Ø 650 700 x 1200kdeEFJSubmersible pumps2 x 1,5" (Ø 47,8 x 3,25)kDIN 2440abc68300D325+ABDN2EF615(550 - 750)CHMGDN1LDN1110Ø 12+Ø 1200 Ø 1500Portable wet sump installationVertical dry sump installationGhf225DN 2ODN1H 1N GTUminPSQ>85R225264494DimensionsWilo-Drain TP 100 ...E160/14, E180/22, E210/30, E230/34,F155/18, F165/22,F180/25, F180/31, F210/34E190/39, E210/52, E230/70, E250/84F195/59, F220/72, F247/84DimensionsA B C D E F G H I J K L M a b c d e k[mm]220 180 18 168 91 228 725 340 100 200 428 225 400 340 300 210 203 16 20220 180 18 168 91 255 745 350 100 223 460 225 400 340 300 210 203 16 20As of: 06/2004 - Subject to change without prior notice89


ISewage/FaecesWilo-Drain TP 80, TP 100, TP 150Dimension Drawings, DimensionsDimension drawings TP 150Stationary wet sump installationdFJ40120+Ø 900 900 x 1600keE7080k2 x 1,5" (Ø 47,8 x 3,25)DIN 2440c+400 500ABDN2DEF920(800 - 950)CHGMDN1L85abDN 18512+Ø 1500 Ø 2000Portable wet sump installationVertical dry sump installationDN 2ODN 1H 1N GTUminGPQR381414hf381819S>85DimensionsWilo-Drain TP 150[mm]DN 1 DN 2 A B C D E F G H I J K L M a b c d e k150 150 285 240 22 237 100.5 320 932 415 100 250 536 265 510 320 280 280 335 11 2090 As of: 06/2004 - Subject to change without prior notice


ISewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesStationary wet sump installationSTS 80/100, TP 80/10054321For STC 80/100see dimension drawing of pumpTP 15054367Item 1aAHItem 1bItem 1a501263BLGHKMJ316346340COPDIN210EØ FWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesSTS, TP: Base elbow (Item 1a)Made of cast iron 25 (EN-GJL-250) includingpump support, profile seal, accessories for mountingand fastening to the ground, and guide pipebracket, cast iron 25 (EN-GJL-250), flanges PN 10/16 to DIN 2501 for DN 80/100.Guide pipe (2 x 1.5") must be provided onsiteSTS/TP 80 STS/TP 100A 300 400B 303.4 339C 180 225D 105 110E 110 130F Ø 40 Ø 48G 225 250H 210.5 238I 118.5 132or Item 1bStainless steel pump support, profile seal, accessoriesfor installation and fastening to the ground,and stainless steel cable guide 10 m for 5 m installationdepth, flanges PN 10/16, to DIN 2501Made of stainless steel, as for item 1a, but withstainless steel cable guide for 5 m installationdepth.TP 80 TP 100/150H 180 240I 345 385J 185 215K 217 350L 232 250M 211 246N 95 95O 182 182P 109 129Stainless steel pump support, profile seal, accessoriesfor installation and fastening to the ground,and stainless steel cable guide 10 m for 5 m installationdepth, flanges PN 10/16, to DIN 2501.Submersible pumps6290182942Item 1b24021538,5095182Made of cast iron 25 (EN-GJL-250), includingpump support, profile seal, and accessories forinstallation and fastening to the ground. The doublepipe guide (R 2) must be provided on-site.1350129246250As of: 06/2004 - Subject to change without prior notice91


Sewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesStationary wet sump installationSTC 80/100, STS 80/100, TP 80/1005Wilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesChain (Item 6)Made of stainless steel, including shackles,length: 5 m and 10 m, lifting capacity: 400kg43267Q*RSCheck valve body (Item 2)Made of cast iron 25, (EN-GJL-250), with unrestrictedpassage, incl. cleaning port and ventilationdevice, installation accessories, flanges PN 10/16,to DIN 2501, with(*) or without draw. No.(draw. No. 53.4-309)DN 80/100/150DN 80 DN 100 DN 150Q 240 270 335R 245 282 397S 260 300 4001TUGate valve (Item 3)Made of cast iron 25, (EN-GJL-250) installationaccessories, flanges PN 10/16 to DIN 2501,DN 80/100/150DN 80 DN 100 DN 150T 295 325 425U 80 190 210TP 150543VWPipe bend (Item 4)Made of nodular graphite iron (EN-GJS-400-15),with 2 flanges, installation accessories for a flangeconnection, flanges PN 10/16, DIN 28637,DN 80/100/150DN 80 DN 100 DN 150V 165 180 220W 165 180 22026XYZY-piece (Item 8)Made of galvanised steel 37, with 2 sets of installationaccessories, flanges PN 10/16, DIN 2501,DN 80/80/80, 100/100/100 or150/150/150DN 80 DN 100 DN 150X 615 615 920Y 168 208 287Z 167 207 2871Ø 5260STS/TP 80/100 pipe joint (Item 7)Made of galvanised steel, fits 2" guide pipe,required for guide pipes longer than 6 m130Installation accessories (Item 5)For a flange connection with 8 screws and nuts and1 flat seal, for flanges PN 10/16, DIN 250192 As of: 06/2004 - Subject to change without prior notice


ISewage/FaecesWilo-Drain STC 80/100, STS 80/100, TP 80-150Mechanical AccessoriesPortable wet sump installationSTS 80/100, TP 80/10015146Ø 1954903080300590359130Ø 22090337,5TP 80/100 ground support foot (Item 9)Made of stainless steel, consists of 3 support feet,1 base plate and mounting hardwareSTS 80 (Item 9a)STS 100 (Item 9b)Consists of 3 support feet, 1 base plate andmounting hardwareSubmersible pumps13230,5380,5Item 9a260428Item 9b1030125TP 150 ground support foot (Item 9)Made of stainless steel, consists of 3 supportfeet, 1 base plate and mounting hardware9441For STC 80/100see dimension drawing of pumpTP 150560Chain (Item 6)Made of stainless steel, including shackles,length: 5 m and 10 m, lifting capacity: 400kg6BACPipe bend (Item 10)Made of stainless steel, can be used for direct hoseconnection or mounting a Storz fixed coupling.Variable set-up possible with 45° hole pitch (TP100/150)DN 80 DN 100 DN 150A G 3 G 4 Ø 148B 240 280 432.5C Ø 89 – –15109FEDGStorz fixed coupling for mounting to pipebend (Item 13)AL, with R3 or R4 female thread for connectionnominal diameter 80/100DN 80 DN 100D 40 48E Ø 78 Ø 100F 105 133G R 3 R 4JHKStorz hose coupling (Item 14)Made of aluminium, for hose inner dia. 90/110 mmDN 80 DN 100H 140 170I 105 133J Ø 80 Ø 100K Ø 90 Ø 110can be wound upPressure hose for direct hose connection(Item 15)Material: Synthetic material PN 8 including 2 hoseclips, hose inner diameter 90/110/150 mm, length10, 20 and 30 mAs of: 06/2004 - Subject to change without prior notice93


Sewage/FaecesWilo-Drain TP 80, TP 100, TP 150Mechanical AccessoriesStationary, vertical dry sump installation TP 80-15023 1818AACWilo-Drain TP 80, TP 100, TP 150Mechanical AccessoriesSet-up set (Item 17)Includes mounting hardware and 2 flange connections(inlet and discharge ends).TP 80 TP 100 TP 150A 225 272 381B 264 337 414C 494 625 819minB1717Q*RSCheck valve body (Item 2)Made of cast iron 25, (EN-GJL-250), with unrestrictedpassage, incl. cleaning port and ventilationdevice, installation accessories, flangesPN 10/16, to DIN 2501, with or without draw. No.(draw. No. 53.4-309) DN 80/100/150TP 80 TP 100 TP 150Q 240 270 335R 245 282 397S 260 300 400TUGate valve (Item 3)Made of cast iron 25, (EN-GJL-250) installationaccessories, flanges PN 10/16 to DIN 2501,DN 80/100/150TP 80 TP 100 TP 150T 325/295* 325 425U 190/180* 190 210* Inlet DN 100/discharge side DN 80DExpansion joint (Item 18)Galvanised steel, PN 10/16, with installationaccessories DN 80/100/150TP 80 TP 100 TP 150D 135/130* 135 180* Inlet DN 100/discharge side DN 80XYZY-piece (Item 8)Made of galvanised steel 37, with 2 sets of installationaccessories, flanges PN 10/16, DIN 2501,DN 80/80/80, 100/100/100 or150/150/150TP 80 TP 100 TP 150X 615 615 920Y 68 208 287Z 167 207 28794 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain Electrical AccessoriesPump Equipment/FunctionWilo-Drain Electrical AccessoriesER1-A SK 530 DrainPump Equipment/FunctionControl PL1ApplicationsDrainControl PL2DrainControl 1DrainControl 2Switchgear for controlling pumps • • • • • • –Alarm switchgear – – – – – – •Number of pumps to be controlled 1 2 1 2 1 2 –Electrical connectionDirect activation [A] max.10 1) max. 2x8 Max.12 max. 2x12 Max.10 max. 2x10 –Star/delta connection optional 1) – – – > 10 A > 10 A –DesignMicroprocessor-controlled – – • • • • –Electronic • • – – – – •Housing materialPlastic • • • • • • •Metal optional – – – – – –EquipmentTest run • – • • – – –Pump start counter/impulse counter – – • • – – –LCD display – – • • • • –LED/indicator lamp • • • • • • –Main switch • – optional optional • • –Ampere meterVolt meteroptionalupon requ.optionalupon requ.– • • • 2) • 2) –– – – – – –Adjustable delay time • – • • • • –Operating hours counteroptionalupon requ.– • • • • –Level detection Float switch • 3) • 3) • 3) • 3) • 3) • 3) –Pneumatic pressure sensor – – • • – – –Level sensor (4-20 mA) – – • 4) • 4) • 4) • 4) –Electrodes – – – – – – •Alarm Mains-operated • • • • • • –Built-in (buzzer) – – • • – – •Pump Duty Cycling – • – • – • –Message/display functionCollective run signal • • – – – – –Collective fault signal • • • • • • –Individual run signal – optional – – • • –Individual fault signal – optional – • – – –Control functions (motor monitor)Thermal winding contacts (WSK) • • • • • • –PTC • – – – • • –Leakage (DI) – – – – • • –Electronic • • • •Protective motor switch – – optional optionalScope of delivery•(up to 10 A)•(>10 A)•(up to 10 A)•(>10 A)Float switch • • – – – – –Signal horn • • – – – – –KAS––Submersible pumps• = available, – = not available1) For other motor power ratings upon request2) For direct activation units only (up to 4 kW)3) In potentially explosive areas only with Ex isolating relay4) In potentially explosive areas only with Zener barrierAs of: 06/2004 - Subject to change without prior notice95


Applications• = available, – = not availableDrain-Alarm2Motor protectionplug CEEIsolationrelay forexplosionprotectionSewage/FaecesWilo-Drain Electrical AccessoriesZenerbarrierPump Equipment/FunctionFlashinglightSignal horn SK 545Switchgear for controlling pumps – • – – – – –Alarm switchgear • – – – – – –Number of pumps to be controlled – 1 – – – – 2Electrical connectionDirect activation – • – – – –Star/delta connection – – – – – –DesignElectronic • – • • • – •–Externalpower pack–Externalpower packElectromechanical – • – – – • –Housing materialPlastic • • • • • • •EquipmentLED/indicator lamp • • • – – – •Level detection Float switch • • • – – – –Level sensor (4-20 mA) – – – • – – –Alarm Battery-operated • – – – – – –Mains-operated • – – – – – –Built-in (buzzer) • – – – – – –Message/display functionIndividual fault signal • – – – – – –Control functions (motor monitor)Thermal winding contacts (WSK) – • – – – – •Leakage (DI) – – – – – – •Protective motor switch – • – – – – –96 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain Electrical AccessoriesDescription of AccessoriesDescription of AccessoriesWilo ER 1-A and Wilo SK 530 switchgearsFor automatic transmitter control of 1 or 2 Wilo-Drain series submersible wastewater/sewage pumps.– W=228 mm, H=265 mm, D=74 mm– Protection class IP 42– Switchover from pump 1 – pump 2 (SK 530)– Motor protection by WSK or electronic motor switch– Transmitter connection for float switch, Type WA 95– Automatic pump duty cycling (SK 530)– Selector switches:"Hand-2-Hand-1-0-Automatic" system (SK 530)"Hand-0-Automatic" system (ER 1-A)– Connection for high water alarm– Volt-free fault signal (changeover contact) and volt-free run signal (changeover contact),– Phase failure monitor (can be switched off)– Includes float switch WA 65, cable length 5 m (2x for ER 1-A, 3x for SK 530) and 230 V signal horn(requires external power supply), included separately in deliveryFor control of pumps in potentially explosive areas, Ex isolating relays must be used.Switchgears are not explosion-protected and may be used outside of potentially explosive areas only.Submersible pumpsP1P2OK. Drain . ControlWilo-DrainControlMicroprocessor-controlled switch unit for the fully automatic control of 1 or 2 Wilo-Drain submersiblewastewater/sewage pumps.• Hand-0-Automatic switch above membrane keyboard• Two-line LCD display with 2 x 16 characters, multi-lingual,menu-controlled operation possible using membrane keyboard• Input terminals for connecting a level probe• Automatic phase failure and phase sequence control• Operating hours counter• Automatic pump duty cycling (Control 2) after each operation sequence• Volt-free contacts for:– Collective fault signal– Signal horn (make contact)– Pump 1 operation (make contact)– Pump 2 operation (make contact) Control 2 only– Main switch– Built-in electronic motor current monitoring• max. ambient temperature 40 °C• Housing: Plastic for wall installation• Type of start-up: Direct or star-deltaFor control of pumps in potentially explosive areas, a level probe (with Zener barrier!) or float switch in conjunctionwith Ex isolating relays must be used.Switchgears are not explosion-protected and may be used outside of potentially explosive areas only.Niveau ControlPS1-LCDWilo-DrainControl PL 1Switchgear for level control of 1 submersible pump using the bubbling-through or dynamic pressuremethod.• LCD display• LEDs for alarm, operation/delay time, manual/automatic operation• Volt-free contacts for collective fault signal and high water alarm• Forced switch-on of the pump• Time-delayed pump stop• Built-in buzzer• Operating hours counterSwitchgears are not explosion-protected and may be used outside of potentially explosive areas only.As of: 06/2004 - Subject to change without prior notice97


Sewage/FaecesWilo-Drain Electrical AccessoriesDescription of AccessoriesWilo . Drain . Control1 2Wilo-DrainControl PL 2Switchgear for level control of 2 submersible pumps. The level can be detected using the bubblingthroughor dynamic pressure method or using an electronic level sensor(4 - 20 mA) or float switch.• LCD display, multi-lingual, adjustable• LEDs for alarm, operation/delay time, manual/automatic operation• Volt-free contacts for collective fault signal and high water alarm, pump 1 fault,pump 2 fault• Forced switch-on of the pump• Time-delayed pump stop• Automatic pump duty cycling after each operation sequence• Automatic fault switchover• Built-in buzzer• Operating hours, pump start countersFor control of pumps in potentially explosive areas, a level probe with Zener barrier or float switch in conjunctionwith Ex isolating relays must be used.Switchgears are not explosion-protected and may be used outside of potentially explosive areas only.Wilo KASMini alarm switchgear with 70 dBA signal bell, signal transmitter (electrode) with 3 m cable, selfrechargingpower supply pack (power reserve approx. 5 hrs.) in ISO plug housing (Schuko), protection classIP 30, 230 V~ / 9V=; 1.5 VA.Wilo Drain-Alarm 2Alarm switchgear for wall installation with visual and acoustic alarm signal(85 dBA buzzer, self-recharging power supply pack, volt-free contact,ISO housing, protective class IP 54, 1~230 V. As the transmitter, a WA typefloat switch is required.DrainAlarm 2Protective motor switch CEE(Up to rated motor power P2 < 4 kW) with phase inverter and rotation direction indicator, thermal motorprotection of the motor. Current ranges:• 2.6 – 3.7 A• 3.7 – 5.5 A• 5.5 – 8 A• 8 – 11.5 AFor TP 80/TP 100, evaluation of the thermal motor protection and leak monitoring.Level probeFor level detection.• Protection class IP 68• Measurement range 0 - 1 m WS; 0 - 2.5 m WS• Cable lengths 10, 30 or 50 m• Output signal 4 - 20 mA98 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-Drain Electrical AccessoriesDescription of AccessoriesFloat switch MS1Cable length 10 m, for sewage containing faeces,for connection to a Wilo-DrainControl 1 or 2.Type WA Float SwitchCable length 5 m, switch setting: high ON/low OFFWA 65 for media up to 65 °CWA 95 for media up to 95 °CSubmersible pumps1 2N L 3 4 5 6 7 8Ex isolating relayFor installation of float switches in potentially explosive areas.Suitable for connection of 3 – 5 float switches. Built into anISO housing, protection class IP 54, with transparent cover, for wall mounting(W = 182 mm, H = 180 mm, D = 165 mm).• 3-circuit (3 float switches can be connected)• 4-circuit (4 float switches can be connected)• 5-circuit (5 float switches can be connected)Zener barrierFor installation of a level probe in potentially explosive areas.Suitable for connection of a level sensor.Protection class IP40, housing for installation in non-potentially explosive areas(W = 75 mm, H = 150 mm, D = 106 mm).1 m pre-attached cable.Switch cabinet - outdoor installation of Wilo-Drain-SystemEmpty cabinet for outdoor installation, with glass fibre-reinforced polyester, with lock, air supply andexhaust. For pedestal mounting. Additional options such as ammeter, volt meter, heating, etc. feasible onrequest and can, if required and in conjunction with a Wilo-Drain-Control, be supplied assembled in theswitch board (at extra costs).(W = 590 mm, D = 320 mm, H = 875 mm)Flashing lightFor installation on control cabinet, outdoor installation, 230 VACAs of: 06/2004 - Subject to change without prior notice99


Sewage/FaecesWilo-Drain Electrical AccessoriesDescription of AccessoriesSignal hornFor connecting to a Wilo-DrainControl, 230 VACDynamic pressure systemThe pressure sensor (bell) senses changes of the fluid level in the shaft. The change of the pressure value inthe bell is transmitted to the Wilo-DrainControl PL via a leak-proof hose, and evaluated by measuring elementsin the switch box.Scope of delivery: Submersible bell wit 10 m hoseBubble-through systemDynamic pressure principle with permanent compressed air supply from the mini air compressor. The bell(dynamic pressure system) must be ordered separately.Scope of delivery: Mini air compressor, 3 m hose with T-piece and non-return valveWilo-SK 545Trigger device for monitoring of up to 2 Wilo TP 80,100 or 150 submersible pumps• For installation into existing switchgear or as a module for conventionally designedswitchgears, installation on 35 mm top hat rail• Phase sequence monitoring• 2-stage leak monitoring• Thermal winding monitoring (WSK)• Operating voltage 3~400 V max. 6 A fuse protection• Volt-free output contacts, max. load 250 V/1 A• Dimensions : H = 72mm, W = 100mm, D = 113mm100 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesSubmersible pumpsAs of: 06/2004 - Subject to change without prior notice101


<strong>Contents</strong>Lifting plants/Wet sump pumping stationsLifting plantsProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 104Product Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 105Condensate/Wastewater/Drainage Water. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Wilo-DrainLift Con . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 108Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 109Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 110Pump Curve, Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 111Wilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 112Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 114Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 115Wilo-DrainLift TMP . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 117Dimension Drawings, Installation Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 118Wilo-DrainLift Box . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119Pump Curves, Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 119Wilo-DrainLift FH/ D-FH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120Pump Curves, Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 120Sewage/Faeces . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Wilo-DrainLift KH . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 121Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 122Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 123Wilo-DrainLift KH 32 . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Pump Curve, Dimension Drawing, Installation Example . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 124Wilo-DrainLift S, M, L, XL, XXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 125Pump Equipment/Function . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 128Technical Data . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 129Wilo-DrainLift S . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131Pump Curve, Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 131Installation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 132Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 133Wilo-DrainLift M . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Pump Curve, Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 134Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 135Wilo-DrainLift L . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Pump Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 136Dimension Drawing . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 137Installation Examples . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 139Wilo-DrainLift XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140Pump Curve . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 140Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 141Installation Example, Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Wilo-DrainLift S, M, L, XL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 142Wilo-DrainLift XXL . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 144Dimension Drawings, Maße . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 145Installation Example, Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 146102 As of: 06/2004 - Subject to change without prior notice


<strong>Contents</strong>Lifting plants/Wet sump pumping stationsWet sump pumping stationsProduct Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 148Product Advantages . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 149Wilo-DrainLift WS, WB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Product Description . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 150Wilo-DrainLift WS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Pump Curve, Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 152Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 154Wilo-DrainLift WB . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Pump Curves . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 155Dimension Drawings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 156Mechanical Accessories . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 159Lifting plants/wet sump pumpingstationsAs of: 06/2004 - Subject to change without prior notice103


Wilo-DrainLift ConDuty chart (2-pole, 50 Hz)5H[m]4321Wilo-DrainLift ConLifting PlantsProduct OverviewWilo-DrainLift Lifting Plants• Condensate lifting plants• Applications:Removal of condensate, can be used in– Condensing boiler applications– Air conditioning and refrigeration systems(such as refrigerators and evaporators)00 50 100 150 200 250 300Q [l/h]Lifting Plants Wilo-DrainLift Lifting Plants Product OverviewWilo-DrainLift TMPDuty chart (2-pole, 50 Hz)H[m]7654321Wilo-Drain TMP• Wastewater lifting plant (above-floorinstallation)• Applications:Automatic drainage for showers, washstands,washing machines and dishwashersetc.Pumping rain, wastewater and drainagewater which does not contain faeces,fibrous materials, oils or fatty wastes.0 0 1 2 3 4 5 6 7 8Q[m 3 /h]Wilo-DrainLiftBoxDuty chart (2-pole, 50 Hz)H[m]108642Wilo-DrainLift Box• Wastewater lifting plant• Applications:For underground installation, can be usedin– Areas at risk of flooding– Garage entrances– Basement hatchways00 2 4 6 8 10 12 14Q [m 3 /h]Wilo-DrainLift FH/D-FHDuty chart (2-pole, 50 Hz)H[m]108642Wilo-Drain FH/D-FH• Wastewater lifting plant• Applications:Removal of water which does notcontain faeces, can be used in– Underground car parks– Pubs and inns– Commercial buildings00 5 10 15 20 25Q[m 3 /h]Wilo-DrainLift KH 32Duty chart (2-pole, 50 Hz)H[m]432Wilo-DrainLiftKH 32-0,4• Mini Sewage Lifting Plant• Applications:For limited use (directly connectedbehind a toilet) with macerator for disposalof wastewater from one toilettogether with one hand washing stand,one shower, or one bidet.100 1 2 3Q[m 3 /h]104 As of: 06/2004 - Subject to change without prior notice


Lifting PlantsProduct AdvantagesWilo-DrainLift Lifting PlantsWilo-DrainLift Con• Low-noise operation• 2 inlet openings• Standard alarm contact• Easy to install• Variable inlets/dischargesWilo-DrainLift TMP• Modern design• Shower drain possible from heights of 110 mm• Low-noise operation via integrated submersible pumpProduct AdvantagesLifting plantsWilo-DrainLiftBox• Easy to install due to built-in pump and non-return valve• Large tank volume• Easy to maintain• Removable pumps with pressure lineWilo-DrainLift FH/DFH• Increased reliability with:– Large collector tank– Large free ball passage• Switchgear with collective fault signal and battery-powered alarmWilo-DrainLift KH 32• Modern, compact design• Straightforward installation with self-sealing, direct toilet connectionAs of: 06/2004 - Subject to change without prior notice105


Lifting PlantsProduct OverviewWilo-DrainLift Lifting PlantsWilo-DrainLift SDuty chart (4-pole, 50 Hz)6H[m]41/51/7Wilo-DrainLift S• Sewage lifting plant• Applications:Suitable for handling untreated sewagewhich cannot be drained by naturalgravity flow to the sewer system.Single room drainage.200 10 20 30 40 50Q[m 3 /h]Wilo-DrainLift MDuty chart (4-pole, 50 Hz)H[m]642Wilo-DrainLift M• Sewage lifting plant• Applications:Suitable for handling untreated sewagewhich cannot be drained by naturalgravity flow to the sewer system.For drainage of single-family homes andsmall building complexes.0010 20 30 40Q[m 3 /h]Wilo-DrainLift LDuty chart (2-pole, 50 Hz)H[m]201510Wilo-DrainLift L• Sewage lifting plant• Applications:Suitable for handling untreated sewagethat cannot be drained by natural gravityflow to the sewer system.For drainage of multifamily houses andsmall facilities (cafés etc.).500 10 20 30 40 50Q [m 3 /h]Wilo-DrainLift XLDuty chart (2-pole, 50 Hz)H[m]2015105Wilo-DrainLift XL• Sewage lifting plant• Applications:Suitable for handling untreated sewagethat cannot be drained by natural gravityflow to the sewer system.For drainage of large facilities (pubs,stores etc.)00 10 20 30 40 50Q[m 3 /h]Wilo-DrainLift XXLDuty chart (4-pole, 50 Hz)H [m]161284Wilo-DrainLift XXL• Sewage lifting plant• Applications:Suitable for handling untreated sewagethat cannot be drained by natural gravityflow to the sewer system.For drainage of building complexes(hotels, hospitals etc.)00 40 80 120 160Q [m 3 /h]Product Overview106 As of: 06/2004 - Subject to change without prior notice


Lifting PlantsProduct AdvantagesWilo-DrainLift Lifting PlantsWilo-DrainLift S• Freely selectable inlets• Wall cavity installation possible• Lightweight• Compact installationWilo-DrainLift M• Freely selectable inlets• Lightweight• Battery-operated alarm• Built-in non-return valve• Large tank volumeLifting plantsWilo-DrainLift L• Freely selectable inlets• Lightweight• Battery-operated alarm• Built-in non-return valve• Large tank volume• Wide range of performance levelsWilo-DrainLift XL• Large tank volume• Battery-operated alarm• Only one discharge outlet (built-in breeches pipe)• Built-in non-return valve• Suitable for continuous operationWilo-DrainLift XXL• Large tank volume• Lightweight• Wide range of performance levels• Suitable for continuous operationProduct AdvantagesAs of: 06/2004 - Subject to change without prior notice107


Condensate/Wastewater/Drainage WaterWilo-DrainLift ConProduct DescriptionWilo-DrainLift ConAutomatic condensate lifting plantType keyExample: Wilo-DrainLift ConConCondensateApplicationsThe condensate lifting plant must be used if disposal is not possiblevia natural gravity flow, or if the installation location is below thebackflow level. It has been designed for installation in condensingboilers that generate aggressive condensate according to the specificationsof the "Arbeitsblatt A 251" as distributed by the ATV(German Association for Water, Wastewater and Waste). Because ofthe materials used in the manufacture of the plant, condensate witha pH value of up to 2.4 can be conveyed without any problems. For oilor gas-fired boilers with an output > 200 kW, the lifting plant mustbe installed downline of a neutralisation system. The condensatelifting plant can also be used in the air-conditioning and refrigerationplants where condensate is produced, for example refrigerators andfreezers, evaporators, and refrigerateddisplay cases.The plant can be installed in free-standing form or vertically wallmountedwith two fastening holes. The positioning of the motor uniton the tank is reversible, allowing a variable inlet and outlet.Design2 inlets in the lid (19 or 24 mm). Hose connection on discharge end,DN 10 mm with built-in check valve.Scope of deliveryFully-assembled lifting plant with standard alarm contact for connectionto condensing boiler or alarm switchgear. Incl. hose connectionwith built-in check valve. 5 m hose for discharge side, 1 m alarmcable and 2 m power cable with Schuko plug, wall-mounting hardwareand installation and operating manual.Accessories– Inlet adapter Ø 19 to 25 mm, Ø 19 to 30 mm,Ø 20 to 40 mm– Pressure hose, 25 m longCondensate/Wastewater/Drainage WaterWilo-DrainLift ConProduct Description108 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift ConPump Equipment/FunctionPump Equipment/FunctionDesign• = available, – = not availableDrainLift ConPump position Motor section outside of tank •Single-pump systemOpen multi-vane impellerMaterialsPump Plastic •Tank ABS •EquipmentLevel control Float switch •Alarm Volt-free contact •Built-in check valve bodyMounting hardwarePressure hose•••••Lifting plantsAs of: 06/2004 - Subject to change without prior notice109


Condensate/Wastewater/Drainage WaterWilo-DrainLift ConTechnical DataTechnical DataApproved fluidsStrongly alkaline condensate (pH ≥ 2.4)Electrical connectionWilo-DrainLift Con•Mains connection [V] 1~230Connected load P 1 [kW] 0.08Rated current [A] 0.8Mains frequency [Hz] 50Cable length from plant to switchgear/plug [m] 2Permissible range of applicationOperating modeS3Fluid temperature, max. [°C] 80ConnectionsDelivery connection [mm] 12Inlet connection [mm] 19/24MotorProtection class IP 20Dimensions/weightsGross volume [l] 1.5Weight [kg] 2• = available or authorised, – = not available or not authorised110 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift ConPump Curve, Dimension DrawingDrainLift Con2-pole, 50 HzPump Curve, Dimension Drawing[m]6Wilo-DrainLift Con54H32100 50 100 150 200 250 300 350Q[l/h]Lifting plantsDimension drawingØ 1282,5169,521195As of: 06/2004 - Subject to change without prior notice111


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHProduct DescriptionWilo-DrainLift TMPWastewater lifting plant (above-floor installation)Type keyExample: Wilo-TMP 32- 0.5 EMTMP Wastewater lifting plant (above-floor)32 Nominal diameter of delivery connection(DN 32 / G 1 1 / 4 )– 0.5 Rated motor power [kW]EM AC 1~230 V, 50 HzApplicationsWastewater lifting plant for the automatic drainage of showers,washstands, washing machines, dishwashers etc. in old or new buildingswhere wastewater cannot be fed to the main sewers by naturalgravity flow or disposal of wastewater from below the backflow level.Suitable for handling drainage water that is free of faecal and fibrousmatter, non-aggressive rainwater, wastewater and drainage waterthat is free of fats and oils. The specifications of DIN EN 12050-2 andDIN 1986-100 must be complied with.Note:Handling of sewage that contains faeces in wastewater lifting plantsis not permitted. For these applications, we recommend using theWilo-DrainLift S-XXL series sewage lifting plants.DesignFully assembled, automatically switching wastewater lifting plantwith all required switching and control equipment and built-in nonreturnvalve.TMP 32:Active carbon filter with overflow protection for air intake andexhaust, 2 inlet ports DN 40 at different height levels, discharge portDN 40 (G 1 1 / 4 ). The ventilation can also be guided to above roof levelwith a self-sealing connecting sleeve (pipe outer diameter 25 mm).TMP 40:Flexibility for use with inlets possible both on the side and on the top(a particular advantage for retrofitted installations), easy-to-maintainsystem construction with built-in TMW 32, DN 40 dischargeport.Wilo-DrainLift BoxSubmersible wastewater plantType keyExample: Wilo-DrainLift Box 32/8Box Wastewater lifting plant32 Nominal diameter of delivery connection(DN32, Ø 40)8 Max. delivery head [m]ApplicationsDrainage of flood-endangered rooms, garage entrances and basementsand basement hatchways as well as showers, washbasins etc.in old and new buildings fur sub-floor installation.DesignAutomatically switching lifting plant with built-in submersible pump.Ready-to-install for sub-floor applications. Flexibility for use withthree inlet options in DN 100, of which one inlet can be used for connectionto another tank.Scope of deliveryFully installed and assembled pump with attached float switch in animpact-proof plastic container for sub-floor installation. Completelyready-to-operate with installed pressure line and non-return valve.Pump cable (5 m or 10 m long) with attached Schuko plug. Installationand operating manual.Wilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHProduct DescriptionScope of deliveryFully assembled, automatically switching wastewater lifting plantwith active carbon filter (for TMP 32) and installation and operatingmanual.112 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHProduct DescriptionWilo-DrainLift FH / D-FHSubmersible wastewater plantType keyFH Single-pump lifting plantD-FH Double-pump lifting plantLifting plantsApplicationsWastewater lifting plant for drainage of sewage free of faeces inaccordance with DIN EN 12056 in buildings located below the backflowlevel. Outside of the area in which DIN EN 12050/12056 is valid,it can also be used as a faeces lifting plant. However, we recommendusing DrainLift S-XXL sewage lifting plants for this purpose.Areas of application:– Basement/drainage, garage entrances, basement hatchways– Underground car parks– Buildings– Wastewater with impurities ≤ 35 mm Ø– Showers and bathtubs– Washing machines, dishwashersDesignFully assembled wastewater lifting plant with a 200-litre or400-litre collector tank.Equipped with 1 or 2 free-flow impeller pumps of series Drain TC 40,TP 50, TP 65.Wilo-DrainLift FH series:Single-pump plant with a 200 l collector tank.AC model with built-in float switch and power cable withSchuko plug.Three-phase current model with switchgear. switchgear with CEEplug, volt-free high water alarm contact, battery-operated alarm.Wilo-DrainLift D-FH series:Double-pump plant with a 400 l collector tank.Pumps available in AC or three-phase current models. Switchgearwith volt-free high water alarm contact, built-in battery-operatedalarm (battery).With automatic duty cycling, standby and peak load operation.Scope of deliveryFully assembled wastewater lifting plant including switchgear or plugand installation and operating manual.As of: 06/2004 - Subject to change without prior notice113


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHPump Equipment/FunctionPump Equipment/Function• = available, – = not availableDrainLift TMP32-0.5.1 EMDrainLift TMP40/8DrainLiftBox 32DrainLiftBox 40Pump/motor sealsIn pumping medium area: Mechanical seal – • • • •Oil seal chamber – – • •DesignPump position Submersible pump in tank • • • • •Single-pump plant • • • • •Double-pump plant – – – – •Free-flow impeller • • • • •DrainLiftFH/D-FHDepending onpumpPatented turbulator – – • – –MaterialsMotor Stainless steel • • • • •Hydraulic housing Plastic • PP-GF30 PP-GF30 –Cast iron – – – EN-GJL-200Depending onpumpDepending onpumpTank Plastic ABS PE PE PE PEEquipmentMotor Temperature (WSK) – • • • •monitorLevel control Float switch – • • • •Pneumatic pressure sensor • – – – –Alarm Battery-operated – – – –Detachable pump cable – – – –•Type-dependentPre-assembled • • • • •Depending onpumpBuilt-in check valve body • • • • –Inlet seal – – – – –Installation kit for pressure line connection • • • • –Mounting hardware • • – – •Active carbon filter • – – – –114 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHTechnical DataWilo-DrainLift ...Technical DataTMP 32-0.5.1 EM TMP 40/8 Box 32/8 Box 32/11 Box 40/10Approved fluidsDomestic sewage not containing faeces • • • • •Domestic sewage containing faeces – – – – –Washing machine soap and water mixture (without longfibreparticles)• • • • •Non-chlorinated shower and bath water • • • • •Strongly alkaline condensate – – – – –Electrical connectionMains connection [V] 1~230 1~230 1~230 1~230 1~230Connected load P 1 [kW] 0.33 0.45 0.45 0.75 0.94Rated motor power P 2 [kW] 0.25 0.37 0.37 0.55 0.6Rated current [A] 1.5 2.1 2.1 3.6 4.4Mains frequency [Hz] 50 50 50 50 50Cable length from plant to switchgear/plug [m] 1.2 2.5 10 10 5Permissible range of applicationOperating mode S 1 (1000 h) S 3 -25% S 3 -25% S 3 -25% S 3 -25%Max. frequency switching[per hour] – 60 60 60 30Max. permitted pressure in the pressure line [bar] 1.0 1.1 1.1 1.1 1.1Fluid temperature, max. [°C] 45 35 35 35 35Fluid temperature, short periods up to 3 min. [°C] 75 90 90 90 –ConnectionsDelivery connection [mm]Inlet connection [mm]Ø 32(G 1 1 / 4 )40(2 x G 1 1 / 4 )Ø 40 Ø 40 Ø 40 Ø 4025/32/40 100 100 100Vent line [mm] 25 32 100 100 100MotorInsulation class F F F F BProtection class IP 44 IP 67 IP 67 IP 67 IP 67Dimensions/weightsGross volume [l] 17 32 85 85 85Switching volume [l] 2.6 15 22 22 30Weight [kg] 7.1 8.0 30 32 38Lifting plants• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice115


Approved fluids• = available or authorised, – = not available or not authorisedCondensate/Wastewater/Drainage WaterWilo-DrainLift TMP, Wilo-DrainLift Box, FH/D-FHFH 40-0.5D-FH 40-0.5FH 40-0.6D-FH 40-0.6Wilo-DrainLift ...FH 50-0.7D-FH 50-0.71) Outside of the area in which DIN EN 12050/12056 is valid, it can also be used as for faeces (outside of buildings)FH 65-1.1D-FH 65-1.1Technical DataFH 65-1.5D-FH 65-1.5Domestic sewage not containing faeces • • • • •Domestic sewage containing faeces – – – – – 1)Washing machine soap and water mixture (without longfibreparticles)• • • • •Non-chlorinated shower and bath water • • • • •Strongly alkaline condensate – – – – –Electrical connectionRated motor power P 2 [kW] 0.5 0.6 0.75 1.1 1.5Rated current for 1~230 V [A] 1.9 4.7 5.5 7.7 –Rated current for 3~400 V [A] – – 2 3.2 3.6Mains frequency [Hz] 50 50 50 50 50Cable length from plant to switchgear/plug [m] 5Permissible range of applicationOperating mode S 3Max. frequency switching[1per hour] 20 20 30 30 30Max. permitted pressure in the pressure line [bar] 2.5 2.5 2.5 2.5 2.5Fluid temperature, max. [°C] 40 40 35 35 35Fluid temperature, short periods up to 3 min. [°C] 60 60 60 60 60Ambient temperature, max. [°C] 40 40 35 35 34ConnectionsFree ball passage [mm] 35 35 44 44 44Delivery connectionInlet connection [mm] 100Vent line [mm] 100MotorInsulation classProtection class (without switch box) IP 68Dimensions/weightsTank volume [l] 200/400Weight [kg] 52/84 49/80 57/94 67/113 68/115G2F116 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMPPump CurvesTMP 32-0,5.12-pole, 50 Hz[m]65Wilo-Drain-TMP32Wilo-DrainLift TMPPump CurvesIn accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.4H32100 1 2 3 4 Q[m 3 /h]0 0,5 1[l/s]QTMP 40/82-pole, 50 HzLifting plants[m]8Wilo-Drain-TMP 40/8In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.6H4200 24 6 80 0,5 1 1,5 22,5[m 3 /h][l/s]QAs of: 06/2004 - Subject to change without prior notice117


Condensate/Wastewater/Drainage WaterWilo-DrainLift TMPDimension Drawings, Installation ExampleDimension drawingsDimension Drawings, Installation ExampleTMP 32-0,5.1419815213ARear viewBFront view300131 = Inlet DN 402 = Inlet DN 40 (shower)3 = Discharge port G1 1/4 (DN 32)4 = Vent line DN 2541214520424A268,5255,5511BTMP 40/83 21385310 30059041 = Pressure line DN 402 = Vent line DN 323 = Inlet DN 32 (wash basin)4 = Inlet DN 25 (washing machine)5 = Inlet DN 40 (shower)7512551040030015078 75Typical installation scheme TMP 32/40Wilo-Opti-Drain-Box- TM P 3 2 - 0,5 E M2 11: Pressure line2: Vent line (optional)1:50DN 401:50180 (TMP 40/8)110 (TMP 32)Wilo-Drain TMP 32 - 0,5 EM1200118 As of: 06/2004 - Subject to change without prior notice


Condensate/Wastewater/Drainage WaterWilo-DrainLift BoxPump Curves, Dimension DrawingsDrainLift Box2-pole, 50 HzH[m]12108Wilo-DrainLift BoxWilo-DrainLift BoxPump Curves, Dimension Drawings1 = DrainLift Box 32/82 = DrainLift Box 32/113 = DrainLift Box 40/10In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.64122300 2 4 6 8 10 12 14 16 [m 3 /h]QDimension drawingsDrainLift Box 32 DrainLift Box 40Lifting plants350Ø 295350Ø 295110Ø 40Ø 5044576070550500730880DN100110Ø 40110100720DN100100720100110DN10030071044576070550500730880DN100110100DN100110DN100Ø 50300710Ø 500Ø 500As of: 06/2004 - Subject to change without prior notice119


Condensate/Wastewater/Drainage WaterWilo-DrainLift FH/ D-FHPump Curves, Dimension DrawingsDrainLift FH/D-FH2-pole, 50 Hz[m]10Wilo-Drain FH/D-FHWilo-DrainLift FH/ D-FHPump Curves, Dimension Drawings1 = FH 40 -0.5 (3~) and D-FH 40 -0.5 (3~)2 = FH 40 -0.6 (1~) and D-FH 40 -0.6 (1~)H86In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.421 200 2 4 6 8 10 12 14 16Q[m 3 /h]2-pole, 50 Hz[m]10Wilo-Drain FH/D-FH3 = FH 50 -0.7 (1~) and D-FH 50 -0.7 (1~)4 = FH 65 -1.1 (1~) and D-FH 65 -1.1 (1~)5 = FH 65 -1.5 (3~) and D-FH 65 -1.5 (3~)H864In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.234500 5 10 15 20 25 30 35Q[m 3 /h]Dimension drawings20FH 40, 50, 65 D-FH 40, 50, 65Baqckflow loop695725Inlet or drain6756501007501050800Gate valveL140520Checkvalve body200REF200 650730Handdiaphragmpump125LØ G1A B BA = Float switch (alarm), B = Float switch (start/stop)120 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift KHProduct DescriptionDesignAutomatically operating mini lifting plant with macerator, all requiredswitch and control equipment, built-in non-return valve, active carbonfilter, flexible discharge port and facilities for connecting a WC,two additional wastewater sources and a vent line.The KH 32 minilifting plant is directly connected to a toilet pan with a horizontalconnecting piece. Connections from additional sanitary fixtures andthe pressure line are at the rear side of unit and can be optionallyconnected to from the right- or left-hand side. The unit is ventedeither directly into the room via an active carbon filter or above rooflevel by means of a vent pipe.Wilo-DrainLift KHMini Sewage Lifting plantType keyExample: Wilo-KH 32- 0.4 EMKH Mini lifting plant with macerator for sewagecontaining faeces32 Nominal diameter of delivery connection (DN25/32)– 0.4 Rated motor power [kW]EM AC 1~230 V, 50 HzApplicationsReady-to-use, limited-use lifting plant for wastewater containingfaeces (for direct connection behind a toilet) with macerator forwaste disposal from a single toilet and additional hand-washingbasin, shower or bidet, from which the wastewater/sewage cannotbe fed to the local sewer system using natural gravity flow, or that isbelow the backflow level. The specifications of DIN EN 12050-3 andDIN 1986-100 must be complied with.For connecting a greater number of sewage sources, or sources of adifferent kind, we recommend using Wilo-DrainLift series products.Inlet connection:– DN 100 (connected directly using sealing collar)– 2 inlets – DN 40 incl. cover plate and one non-return valveDischarge side connection:– Delivery connection: elbow hose connector DN 25/32 includingnon-return valveVent line:Either integrated active carbon filter with overflow protection orseparate vent pipe above roof level using a self-sealing connectingsleeve (pipe outer diameter 25 mm).Scope of deliveryFully assembled lifting plant with macerator, active carbon filter,flexible discharge port and installation and operating manual.Sewage/FaecesWilo-DrainLift KHProduct DescriptionLifting plantsmax. discharge line lengths DN 32,for best performance, the discharge line should be laidfirst as vertical as possible and then as horizontal as possible(2 x 90-degree bends and one integrated non-return valveare taken into account)Delivery head in m4,03,53,02,52,01,51,020 m25 m30 m35 m40 m45 m50 m0As of: 06/2004 - Subject to change without prior notice121


Sewage/FaecesWilo-DrainLift KHPump Equipment/FunctionPump Equipment/FunctionDesign• = available, – = not availableDrainLift KH 32-0.4 EMPump position Submersible pump in tank •Single-pump plantFree-flow impellerMaceratorMaterialsMotor housing Stainless steel 1.4301Hydraulic housing Plastic PP-GF30Tank Plastic ABSEquipmentLevel control Pneumatic pressure sensor •Pre-assembledBuilt-in check valve bodyInlet sealInstallation kit for pressure line connectionMounting hardwareActive carbon filter•••••••••122 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift KHTechnical DataTechnical DataApproved fluidsDomestic sewage not containing faecesDomestic sewage containing faecesWashing machine soap and water mixture(without long-fibre particles)Non-chlorinated shower and bath waterElectrical connectionWilo-Drain Lift KH 32-0.4 EMMains connection [V] 1~230Connected load P 1 [kW] 0.45Rated current [A] 2.1Mains frequency [Hz] 50Cable length from plant to switchgear/plug [m] 1.2Permissible range of applicationOperating mode Intermittent service S3, 28%/36 sec. according to DIN EN 600034-1Max. frequency switching[per hour] 100Switch-on level (measured from floor) [mm] 70Max. permitted pressure in the pressure line [bar] 0.7Fluid temperature, max. [°C] 35Ambient temperature, max. [°C] 35ConnectionsFree ball passage [mm] 10Delivery connection [mm] DN 25/32Inlet connection [mm]••••2 x DN 40DN 100Vent line [mm] 25Min. inlet height (lowest point to top edge of inlet) 180MotorInsulation classProtection class IP 44Dimensions/weightsGross volume [l] 17Switching volume [l] 2.6Impoundment volume (lowest point to top edge of inlet)[l]Weight [kg] 7.8F15.5Lifting plants• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice123


Sewage/FaecesWilo-DrainLift KH 32Pump Curve, Dimension Drawing, Typical Installation SchemeKH 322-pole, 50 Hz[m]5Wilo-DrainLift KH 32-0,4Wilo-DrainLift KH 32Pump Curve, Dimension Drawing, Typical Installation SchemeIn accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.4H32100 1 2 3Q[m 3 /h]Dimension drawing2A1B5323,52276,5319815241414520445A255,5511B268,51 W.C.-Inlet DN 1002 Inlet DN 403 Connection pressure tube4 Inlet DN 405 VentTypical Installation Scheme211: Discharge line2: Vent line (optional)DN 401:50DN 401:50(*110)≥ 180180≥ 120 0270124 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLProduct DescriptionDesignStainless steel motorProven construction in modern INOX & composite design, incl. highefficiencyfree-flow impeller.Carrying handle and fastening plateSimple to handle, secure fastening in compliance with applicablestandards.Inlet DN 40For additional inlets from washstands, bathtubs etc.Wilo-DrainLift SSewage lifting plantType keyExample: Wilo-DrainLift SSSewage lifting plant for wall cavityinstallations, direct toilet connection or completeroom drainageFreely selectable inletsFree surfaces on both side walls and one front wall allow the greatestdegree of connection flexibility (see graphic below). Observe theminimum inlet height of the drainage sources.Mounting beadsFor commercially available free-standing installation systems.Standard sound insulation matsPrevent transmission of mechanical vibration.Lifting plantsApplicationsComplete, fully assembled sewage lifting plant to DIN EN 12050-1.Suitable for handling untreated sewage which cannot be disposed ofby natural gravity flow to the sewer system.Wilo-DrainLift S meets the requirements of DIN EN 12050-1 as wellthe construction and testing requirements of the Deutsches Institutfor Bautechnik (2The German Institution for Structural Engineering").Compact dimensions and a small base area requirement allow a multitudeof applications, such as:– Retrofitting of showers, toilets, saunas etc.– Installing toilets in basement apartments– Adding on/renovating apartments and buildingsInnovative combination of different installation options of sewagelifting plants into a single device, such as:– Direct toilet connection– Single-room drainage– Free-standing/back-to-wall installationLarge inspection opening. Sloping collection chamber for sedimentfree,reliable operation. Available connections for a vent line DN 70and for a hand diaphragm pump.Scope of deliveryFully assembled sewage lifting plant including switchgear/plug, curvecutter and installation and operating manual.Connection flexibilitySuitable for the following types of installations:As a conventional sewage lifting plant for connection to a wallmountedor free-standing WC or for drainage of an entire room.Requires a minimum of space because of the compact dimensions ofthe plant.In conjunction with free-standing or back-to-wall installation as asewage lifting plant, integrated into commercially available freestandinginstallation systems in both back-to-wall and pedestaltypeversions.Wilo-DrainLift S, M, L, XL, XXLProduct DescriptionNote:After the tiles are applied, the plant must be able to be freelyinstalled and removed. Always refer to and observe the instructionsof the installation manuals for unit and accessories.As of: 06/2004 - Subject to change without prior notice125


Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLProduct DescriptionOptionDrainLift L1/L2 C model, switchgear with individual fault signal andadjustable delay time.Scope of deliverySee "Pump equipment/Function" table.Wilo-DrainLift M, L, XLSewage lifting plantType keyExample: DrainLift L1/25(3~)Sewage lifting plant for drainage ofresidential and commercial buildingsM1/L1 = Single-pump plantsM2/L2/XL2 = Double-pump plants/25 Max. delivery head [m](1~) AC – 1~230 V, 50 Hz(3~) Three-phase current – 3~400 V, 50 HzApplicationsSewage lifting plant for drainage of residential and commercial buildings(e.g. pubs, stores etc.) Untreated sewage that cannot be fed tothe public sewer system by gravity flow and sewage coming in fromtoilets below the backflow level must, according to the requirementsof DIN EN 12056/DIN 1986-100, be fed to the public sewer systemusing an automatic lifting plant. Sewage containing petroleum oils orhazardous substances must be disposed of via an oil or petrol trap,those containing fats via a grease trap and those containing sand viaa sand trap. For installations in which the feed to the lifting plant maynever be interrupted during normal operation, the lifting plant mustbe equipped with a second conveyor (DrainLift M2/L2/XL2) withequivalent capacity, which switches on automatically when necessary(DIN EN 12050-1 A1).DesignFully assembled, fully submersible sewage lifting plant (submersionheight: 2m, submersion duration: 7 days) with gas-tight and watertightcollection tank and buoyancy protection. Centrifugal pumpwith free-flow impeller.DrainLift M1/L1Single-pump plant with AC or three-phase motor for automaticoperation. Switchgear with Schuko or CEE plug, volt-free contact,built-in alarm, built-in battery for mains-independent operation.DrainLift M2/L2/XL2:Double-pump system with three-phase motor for automatic operation(with automatic duty cycling, standby and peak load operation).Built-in double non-return valve requires only one pressure line connection.Switchgear with Schuko or CEE plug, volt-free contact,built-in alarm, built-in battery for main-independent operation.126 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLProduct DescriptionScope of delivery– Microprocessor-controlled switchgear for automatic duty cycling,standby and peak load operation. Volt-free contacts and runningand fault indicator lights for each pump.– Flexible hose connection for vent line DN 70– Flexible hose connection for connecting a hand diaphragm pump.– Set containing fittings for pump to tank connections (includingvent flange and hose)See also "Pump equipment/Function" table.Wilo-DrainLift XXLSewage lifting plantType keyExample: DrainLift XXL 1080-2/8.4XXL Packaged sewage set for large projects10(8) Discharge port DN 100(80)80 Total volume 800 l40 = Total volume 400 l2 Double-pump plant8.4 Power P 2 per pump [kW]Lifting plantsApplicationsUntreated sewage that cannot be fed to the public sewer system bygravity flow and sewage coming in from toilets below the backflowlevel must therefore (according to the requirements of DIN 1986/EN 12050) be fed to the public sewer system using an automatic liftingplant.Sewage containing petroleum oils or hazardous substances must bedisposed of via an oil or petrol trap, those containing fats via a greasetrap and those containing sand via a sand trap.Sewage containing acid must first be neutralised. For sewage linesthat cannot be interrupted, a standby pump (double-pump plant) isrequired in accordance with DIN 1986/EN 12050.DesignFully assembled, fully submersible compact plant (submersionheight: 2m, flood duration: 7 days) with one or two gas-tight andwatertight collection tanks.Equipped with two Wilo-Drain TP 80 or TP 100 series sewage pumps(material: Inox and composite). Easy handling due to the low totalweight of the plant; for example, double-pump plant with TP 80pump is only 160 kg (heaviest part: the pump, at 62 kg). Excellenttank drainage due to low suction location.Note: The switchgear is not submersible and thus must be installedin such a way that it is protected from flooding.As of: 06/2004 - Subject to change without prior notice127


Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLPump Equipment/FunctionPump Equipment/Function• = available, – = not availableDrainLiftS1/5DrainLiftS1/7DrainLiftM1DrainLiftM2DrainLiftL1DrainLiftL2DrainLiftXL2Pump/motor sealsIn pumping medium area:Mechanical seal • • • • • • • •Oil seal chamber • • • • • • • •DesignPump position Motor section outside of tank • • • • • • • –Submersible pump, dry external – – – – – – – •Freely selectable inlet position • • • • • • – –Single-pump plant • • • – • – – –Dual pump station – – – • – • • •Open single-vane impeller – – – – – – – •Free-flow impeller • • • • • • • –MaterialsMotor housing Stainless steel 1.4404Hydraulic Plastic PURTank Plastic PEEquipmentForced-flow casing cooling – – – – – – • •Motor Temperature (WSK) • • • • • • • •Monitoring Leakage – – – – – – – •Level control Float switch – – • • • • • •Pneumatic pressure sensor • • – – – – – –Alarm Battery-operated – – • • • • • –Volt-free contact • • • • • • • •Detachable pump cable • • • • • • • •Pre-assembled • • • • • • • –Check valve body • • • • • • • –Inlet seal • • • • • • – –Curve cutter for drilling inlet hole • • • • • • – –Hose connection for vent • • • • • • • •Hose connection for hand diaphragm pump • • • • • • • •Installation kit for pressure line connection – • • • • • • •Mounting hardware • • • • • • • •Soundproofing materials • • • • • • – –Switchgear – – • • • • • •DrainLiftXXL128 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLTechnical DataWilo-DrainLift ...Technical Data S1/5 S1/7 M1 M2 L1/10/15/20/25Approved fluidsL2/10/15/20/25Domestic sewage not containing faeces • • • • • • •Domestic sewage containing faeces • • • • • • •Washing machine soap and water mixture(without long-fibre particles)• • • • • • •Non-chlorinated shower and bath water • • • • • • •Electrical connectionConnected load P 1 at 1~230 V, 50 Hz [kW] 1.25 1.6 1.6 1.6 – – –XL10/15/20/25Connected load P 1 at 3~400 V, 50 Hz [kW] 1.1 1.5 1.5 1.5 2.95 - 5.3 2.95 - 5.3 2.95 - 5.3Rated current at 1~230 V, 50 Hz [A] 6.8 7.5 7.5 7.5 – – –Rated current at 3~400 V, 50 Hz [A] 2.6 3.0 3.0 3.0 5.95 - 8.9 5.95 - 8.9 5.95 - 8.9Mains frequency 50 50 50 50 50 50 50Pump speed [rpm] 1,450 1,450 1,450 1,450 2,900 2,900 2,900Cable length from plant to switchgear/plug [m] 4 4 4 4 4 4 4Permissible range of applicationOperating mode S3 15% S3 15% S3 15% S3 15% S3 15% S3 15%Max. frequency switching[per hour] 30 30 30 60 30 60 60Switch-on level (measured from floor) [mm] 180 180 170 180 170 180 650Max. permitted pressure in the pressure line [bar] 1.5 1.5 1.5 1.5 2.5 2.5 2.5Fluid temperature, max. [°C] 35 35 40 40 40 40 40Fluid temperature, short periods [°C] 60 60 60 60 60 60 60Ambient temperature, max. [°C] 40 40 40 40 40 40 40ConnectionsFree ball passage [mm] 40 40 45 45 40 40 40Delivery connection [mm] DN 80 DN 80Inlet connection [mm]DN 40DN 100DN 40DN 100DN 65DN 80DN 40DN 100DN 65DN 80DN 40DN 100Vent [mm] DN 70DN 65DN 80DN 40DN 100DN150DN 65DN 80DN 40DN 100DN150Min. inlet height (lowest point to top edge of inlet) 180 180 180 180 180 180 700MotorInsulation classProtection class (without switch box) IP 67Dimensions/weightsGross volume [l] 45 45 90 130 90 130 440Switching volume [l] 20 20 30 40 30 40 220Weight [kg] 30 30 45 72 55 85 135HS1S3 60%DN 65DN 80DN 100DN 150Lifting plants• = available or authorised, – = not available or not authorisedAs of: 06/2004 - Subject to change without prior notice129


Approved fluidsDomestic sewage not containing faecesDomestic sewage containing faecesWashing machine soap and water mixture(without long-fibre particles)Non-chlorinated shower and bath waterElectrical connection• = available or authorised, – = not available or not authorised840-2/1.4880-2/1.4840-2/1.8880-2/1.8Sewage/FaecesWilo-DrainLift S, M, L, XL, XXLWilo-DrainLift XXL...1040-2/3.91080-2/3.9••••1040-2/5.21080-2/5.21040-2/7.01080-2/7.0Technical Data1040-2/8.41080-2/8.4Mains connection [V] 3~400 3~400 3~400 3~400 3~400 3~400Connected load P 1 [kW] 1.9 2.3 4.4 6.2 8.4 10.0Connected load P 2 [kW] 1.4 1.8 3.9 5.2 7.0 8.4Rated current [A] 4.5 5.1 10.5 12.8 15.6 18.1Mains frequency 50Pump speed [rpm] 1,450Cable length from plant to switchgear/plug [m] 10Permissible range of applicationOperating modeMax. frequency switching [per hour] 60Switch-on level (measured from floor) [mm] 560Max. permitted pressure in the pressure line [bar] 2.5Fluid temperature, max. [°C] 40Fluid temperature, short periods [°C] 65Ambient temperature, max. [°C] 40ConnectionsFree ball passage [mm] 80Delivery connection [mm] DN 80 DN 100Inlet connection [mm]S33 x DN 100/1501 x DN 100Vent [mm] 70Min. inlet height (lowest point to top edge of inlet) [mm] 700MotorInsulation classProtection class (without switch box) IP 68Dimensions/weightsGross volume [l] 400/800Switching volume [l] 200/400Tank volume [l] 400/2 x 400Weight [kg] 160/195 195/230F130 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift SPump Curve, Dimension DrawingDrainLift SWilo-DrainLift SPump Curve, Dimension Drawing4-pole, 50 Hz[m]Q minDN 80Q minDN 100Wilo-DrainLift S1 = DrainLift S 1/52 = DrainLift S 1/76H4In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.2100 10 20 30 40 50Q2[m 3 /h]Lifting plantsDimension drawingDN80/1003DN80DN80190213503922604250180350250180135180250350150 30079934015053371937879963763002451501007As of: 06/2004 - Subject to change without prior notice131


Sewage/FaecesWilo-DrainLift STypical Installation SchemesTypical installation schemesDirect toilet connectionTypical Installation Schemes250180Free-standing type1 1 11 Installation FrameHand diaphragm pump connected when neededStationary hand diaphragm pump connection132 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift SMechanical AccessoriesMechanical accessories55Mechanical AccessoriesSingle ended flange nipples (Item 1)DN 80/100 (in the scope of delivery of the DrainLiftS 1/7 plant).1260Check valve body (Item 2)With unrestricted passage, installation accessories,flanges PN 10/16, to DIN 2501, DN 8032240*245* Dimensionwith Z No.4180Gate valve (Item 3)Made of cast iron 25 (EN-GJL-250), installationaccessories, flanges PN 10/16 to DIN 2501, DN 80180Ø 75220295°45Vent combination pipe (Item 4)DN 70, plastic, for connecting the hand diaphragmpump in an emergencyLifting plantsHand diaphragm pump (Item 5)R 1 1 ⁄ 2 , 16 kgInstallation accessoriesFor a flange connection with 8 screws and nuts and1 flat seal, for flanges PN 10/16, DIN 2501, DN 80Inspection frame(H 50 x W 85 cm) steel door, painted white for freestanding-typeinstallationMetal door 800 x 500 mmMagnets to holdmetal doorMetal doorfor tilesInspection frame(H 50 x W 85 cm) Sheet steel, suitable for tiledinstallationsInstallationdepth 85 mmConcealed distribution boxIncl. motor protection, acoustic alarm signal forWilo-DrainLift S with bare cable endWilo KASMini alarm switchgear with 70 dBA signal bell, signaltransmitter (electrode) with 3 m cable, selfrechargingpower supply pack (power reserveapprox. 5 hrs.) in ISO plug housing (Schuko).Protection class IP 30, 230 V~/9 V=; 1.5 VAAs of: 06/2004 - Subject to change without prior notice133


Sewage/FaecesWilo-DrainLift MPump Curve, Dimension DrawingDrainLift MWilo-DrainLift MPump Curve, Dimension Drawing4-pole, 50 Hz[m]Q minDN 80Q minDN 100Wilo-DrainLift MIn accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.6H4200 10 20 30 40 50Q[m 3 /h]Dimension drawing DrainLift M1DN 40DN 7050505552505552501804518045400DN 40770Angle bracketDN 4050504630DN 10055174188 77710200134 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift MDimension DrawingDimension drawing DrainLift M2Dimension DrawingDN 40DN 705050Lifting plants5552501804525018045470640DN 40755Angel bracketDN 4050DN 10083070065215188 77,5710400As of: 06/2004 - Subject to change without prior notice135


Sewage/FaecesWilo-DrainLift LPump CurveDrainLift LWilo-DrainLift LPump Curve2-pole, 50 Hz[m]Q minDN 80Q minDN 100Wilo-DrainLift L1 = DrainLift L 1/10 and L 2/102 = DrainLift L 1/15 and L 2/15203 = DrainLift L 1/20 and L 2/204 = DrainLift L 1/25 and L 2/2515H104In accordance with EN 12056-4.6.1, a flowvelocity (in the pressure line) of between0.7 and 2.3 m/s is to be maintained.351200 10 20 30 40 50 60Q[m 3 /h]136 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift LDimension DrawingDimension drawingDrainLift L1Dimension DrawingDN40505040055525018045DN40770DN4045565630Lifting plantsAngle bracket630504557750174192,5715200As of: 06/2004 - Subject to change without prior notice137


Sewage/FaecesWilo-DrainLift LDimension DrawingDimension drawingDrainLift L2DN40DN70555565502501804550DN40640830700DN40 7556519371550630Angle bracket45400138 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift LTypical Installation SchemesTypical installation schemes3 576Backflow level(usually road tops)01 Gate valve DN 100 or DN 150(accessories)02 Single ended flanged nipple DN 100 orDN 150 with hose (accessories)03 Single ended flanged nipple DN 80/10004 Check valve body (built intodischarge pipe)05 Gate valve DN 80 (accessories)06 Switchgear DrainLift L07 Hand diaphragm pump (accessories)08 3-way stop cock (accessories)09 Check valve body (accessories)10 Drainage pump (Twister)11 Vent connection (DN 70)111489Typical Installation SchemesLifting plants102180 250As of: 06/2004 - Subject to change without prior notice139


Sewage/FaecesWilo-DrainLift XLPump CurveDrainLift XLWilo-DrainLift XLPump Curve2-pole, 50 Hz[m]20Q minDN 80Q minDN 100Wilo-DrainLift XL1 = DrainLift XL 2/102 = DrainLift XL 2/153 = DrainLift XL 2/204 = DrainLift XL 2/2515H1051234In accordance with EN 12056-4.6.1,a flow velocity (in the pressure line) ofbetween 0.7 and 2.3 m/s is to bemaintained.00 10 20 30 40 50 60Q[m 3 /h]140 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift XLDimension DrawingDimension drawingDimension Drawing5050DN 40DN 70680100700100090050575Lifting plantsØ 160840640Ø 10193975990975110070460640Ø 10 DN 40As of: 06/2004 - Subject to change without prior notice141


Sewage/FaecesWilo-DrainLift S, M, L, XLDimension Drawings, AccessoriesTypical Installation SchemeDimension Drawings, Accessories11135678Backflow level(usually roadtops)01 Gate valve DN 100 or DN 150(accessories)02 Single ended flanged nipple DN 100 orDN 150 with hose (accessories)03 Single ended flanged nipple DN 80/10004 Check valve body (built intodischarge pipe)05 Gate valve DN 80 (accessories)06 Switchgear DrainLift XL07 Hand diaphragm pump (accessories)08 3-way stop cock (accessories)09 Check valve body (accessories)10 Drainage pump (e.g. Twister)11 Vent connection (DN 70)42910Inlet connection:Wilo-DrainLift S, M, L, XLAccessoriesGate valve * (Item 1)DrainLiftSDrainLiftMDrainLiftLDrainLiftXLDNDDN L [mm] D [mm]100 190 325150 210 425DN 100DN 100orDN 150DN 100orDN 150DN 100orDN 150LDNLSingle ended flanged nipple with hoseand hose clip * (Item 2)DNL [mm]100 190150 2102xDN 1002xDN 100or2xDN 1502xDN 100or2xDN 1502xDN 100or2xDN 150Discharge side connection:Check valve body * (Item 4)HDN H [mm] L [mm]80 245 260DN 80 built-in built-in built-inLGate valve * (Item 5)DN L [mm] D [mm]80 180 295 DN 80 DN 80 DN 80 DN 80DNDLDNLSingle ended flanged nipple with hoseand hose clip * (Item 3)DNL [mm]80 180100 190S 1/5DN 80S 1/7DN 80/100built-in80/100built-in80/100built-in80/100built-in142 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift S, M, L, XLAccessoriesOther connections/accessoriesR1 1 /2Wilo-DrainLift S, M, L, XLAccessoriesHand diaphragm pump 1 1/2(Item 7)DrainLiftSDrainLiftMDrainLiftLDrainLiftXL500378• • • •246R1 1 /23-way stop cock (Item 8)• • • •KAS *,Mini alarm switchgear with signal bell•Built-in,battery-operated alarm systemLifting plantsorDrainAlarm 2 *, battery-operated alarmwith visual and acoustic alarm•Built-in,battery-operated alarm systemDrainAlarm 2* Required for installation in accordance with applicable standards/recommendations.As of: 06/2004 - Subject to change without prior notice143


DrainLift XXL4-pole, 50 HzH[m]2016128Wilo-DrainLiftXXLWilo-DrainLift XXLPump CurvesSewage/FaecesWilo-DrainLift XXLPump Curves1 = DrainLift XXL 840-2/1.4 and 880-2/1.42 = DrainLift XXL 840-2/1.8 and 880-2/1.83 = DrainLift XXL 1040-2/3.9 and 1080-2/3.94 = DrainLift XXL 1040-2/5.2 and 1080-2/5.25 = DrainLift XXL 1040-2/7.0 and 1080-2/7.06 = DrainLift XXL 1040-2/8.4 and 1080-2/8.4In accordance with EN 12056-4.6.1, a flow velocity(in the pressure line) of between 0.7 and 2.3 m/s isto be maintained.4Q min Q min4DN 80 DN 1001 23004080120160[m 3 /h]0 10 20 30 40 50 [l/s]Q56Dimension drawingsSingle Tank Wilo-DrainLift XXLDimension DrawingØ 75Air ventingHand diaphragmpump200DN80/DN100780 880170 815170FHG700Inlets optionalØ 110/160850 200 19031 788 463CAManual diaphragmpump connection Ø 50500BDEInlets optionalØ 110/160144 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift XXLDimension Drawing, DimensionsDimension drawingsDimension Drawing, DimensionsDual Tank Wilo-DrainLift XXLØ 75Air ventingHand diaphragmpump200DN80/DN100880700TankconnectionLifting plantsManual diaphragmpump connection Ø 50Inlets optionalØ 110/160815560560170 60B840HG850200 190D31 788 463CA170FEInlets optionalØ 110/160Inlet optionalØ 110DimensionsWilo-DrainLift XXL...840 and 880-2/1.4840 and 880-2/1.81040 and 1080-2/3.91040 and 1080-2/5.21040 and 1080-2/7.01040 and 1080-2/8.4ABwith 1 tankBwith 2 tanksDimensionsC D E F G H DN 80 H DN 100[mm]1,965 930 1,695 1,345 238 500 260 180 1,470 1,5501,990 960 1,710 1,355 260 547 300 190 - 1,650As of: 06/2004 - Subject to change without prior notice145


Sewage/FaecesWilo-DrainLift XXLDimension Drawings, AccessoriesTypical Installation:Wastewater and sewage lifting plant (sewage includingfaeces); Wilo-DrainLift XXLl double-pump plantInletVentilation1 2 3 594a111087612Backflow level(usually roadtops)Dimension Drawings, Accessories01 Gate valve DN 100 or DN 150(accessories)02 Single ended flanged nipple with hose andhose clip03 Flexible vent hose connector04 Connector installation kit04a Gate valve DN 10005 Hand diaphragm pump (accessories)06 Check valve body07 Gate valve08 Single ended flanged nipple with hose andhose clip09 3-way stop cock (accessories)10 Breeches pipe11 Microprocessor controlled switchgear12 Mini alarm switchgear4Drainage pumpInlet connection:Gate valve * (Item 1)Pump curves 1 and 2Pump: TP 80Discharge port DN 80Pump curves 3 to 6Pump: TP 100Discharge port DN 100LDNDDN L [mm] D [mm]100 190 325150 210 425DN 100 or DN 150 DN 100 or DN 150DNDischarge side connection:LSingle ended flanged nipple with hoseand hose clip * (Item 2)DNL [mm]100 190150 210Check valve body * (Item 6)DN 100 or DN 150 DN 100 or DN 150HLDN H [mm] L [mm]80 245 260100 282 300DN 80 (x 2) DN 100 (x 2)Gate valve * (Item 7)LDNDN L [mm] D [mm]80 180 295100 190 325DN 80 (x 2) DN 100 (x 2)DDNLSingle ended flanged nipple with hoseand hose clip * (Item 8)DNL [mm]80 180100 19080/100 190DN 80 (x 2)orDN 80/100 (2x)DN 100 (x 2)146 As of: 06/2004 - Subject to change without prior notice


Sewage/FaecesWilo-DrainLift XXLDimension Drawings, AccessoriesGate valve (Item 10)Pump curves 1 and 2Pump: TP 80Discharge port DN 80Pump curves 3 to 6Pump: TP 100Discharge port DN 100ABDN A [mm] B [mm] No. oftanks80 500 260 1100 500 465 180 260 2100 465 2DN 80/80/80 DN 100/100/100Other Connections(no illustration available)Installation set for pump to tank connectionsincl. vent flange and hose andflexible connection to hand diaphragmpump (Item 4)Included in the scope ofdeliveryIncluded in the scope ofdeliveryLDNGate valve * (Item 4)DN L [mm] D [mm]100 190 325DN 100 (x 2) DN 100 (x 2)Lifting plantsDR1 1 /2500378R1 1 /2Hand diaphragm pump R 1 1 / 2(Item 5)AccessoriesAccessories246DNLFlexible hose connection for vent(Item 3)DNL [mm]70 130Included in the scope ofdeliveryIncluded in the scope ofdelivery3-way stop cock (Item 9)AccessoriesAccessoriesMicroprocessor-controlled switchgear(Item 11)Included in the scope ofdeliveryIncluded in the scope ofdeliveryKAS * (Item 12), mini alarm switchgearwith signal bellAccessoriesAccessoriesorDrainAlarm 2 *, battery-operated alarmsystem with visual and acoustic alarmAccessoriesAccessoriesDrainAlarm 2* Required for installation in accordance with applicable standards/recommendations.As of: 06/2004 - Subject to change without prior notice147


Wet Sump Pumping StationsProduct OverviewWilo-DrainLift WSDuty chart (2/4-pole, 50 Hz)H[m]322416 TP 40SWilo-DrainTP40S, TP50,TP65, TP80,• Moulded PE sump pump station• Applications:For pumping wastewater and sewagefrom building systems, rooms and surfacesunder the backflow level outsideof buildings.8TP 50TP 65 TP 8000 20 40 60 80 100Q[m 3 /h]Wilo-DrainLift WBDuty chart (2-pole, 50 Hz)H[m]3224168TP50TP40 STP6500 10 20 30 40 50Duty chart (4-pole, 50 Hz)Wilo-DrainTP40S, TP50, TP65Q[m 3 /h]• Sump pump station, concrete• Applications:Mechanical building services for collectionand pumping of wastewater andsewage from– Basement floors– Air raid shelters– Underground car parkingMunicipal and industrialsewage disposal.H[m]25Wilo-DrainTP80 - TP1502015105TP 80TP 100TP 15000 50 100 150 200 250 300Q[m 3 /h]Duty chart (2/4-pole, 50 Hz)H[m]60Wilo-DrainSTC 80/10050403020STC 80STC 100100 40 80 120 160 200Duty chart(4-pole, 50 Hz)H[m]20Q[m 3 /h]Wilo-DrainSTS 80/10015105STS 80STS 10000 50 100 150 200Q[m 3 /h]Wet Sump Pumping StationsProduct Overview148 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsProduct AdvantagesWilo-DrainLift WS• Sediment-free collection chamber• Maximum stability due to hemispherical shaft bottom• 2/4 inlets selectable on-siteWilo-DrainLift WB• Large scope of delivery• Allows individual solutionsProduct AdvantagesWet Sump Pumping StationsAs of: 06/2004 - Subject to change without prior notice149


Wet Sump Pumping StationsWilo-DrainLift WS, WBProduct DescriptionTP 40 SFor heavily contaminated fluids and sewage. Explosion protection asstandard (3~400 V only), detachable power cable. With patentedmacerator:– Inside rotating blade– Conically designed macerator– Absolutely reliable operationWilo-DrainLift WSMoulded PE sump pump stationType keyExample: WS 900 E/TP 40 SWS Moulded PE sump pump station900 Sump diameter900 = 900 mm1,100 = 1,100 mmETP 40 SE = Single pumpD = Double pumpSelected pump typeApplicationsPumping wastewater and sewage from building systems, rooms andfrom surfaces below the backflow level (EN 752/EN 12050). Themoulded PE sump pump station is designed for outdoor undergroundinstallation without the necessity of associated concrete work. Atimesaving, cost-effective and easy-to-install solution for everyplanner and builder.Suitable for use as a ready-to-install sump pump station in pressuredrainage applications and as a collector pump station in gravitydrainage systems.Applicable Pump TypesDesign– Maximum working load 5 kN/m 2 (in accordance with DIN EN 124,Group 1)– Maximum pressure in the pressure line 6 bar– Moulded PE sump pump station made of recyclable PE– Highest degree of buoyancy protection due to 2/4 (WS 900 = 2,WS 1100 = 4) side fins fitted as standard (no concrete ringsrequired)– 2/4 inlets selectable on-site– Maximum stability due to hemispherical shaft bottom– Wilo above-water coupling– 2 ports DN 100 for vent and power cable– Sediment-free collection chamber due to hemispherical shapeofthe pump sump– Easy access to the level sensor due to installation with suspendedholding rodScope of delivery– Stainless steel discharge pipe from pump discharge port toapprox. 10 cm outside the shaft– Above water coupling system including seals– Check valve, gate valve, completely assembled– Flushing connection G 1 1 / 2– Stainless steel chain including fixing hook– Holding pipe for level monitoring (level sensor Type N,Float switch)– Installation and operating manualDouble pump stations are always supplied with twice the number ofabove-water couplings and fittings.Wet Sump Pumping StationsWilo-DrainLift WS, WBProduct DescriptionTS 40For slightly contaminated fluids, 10 mm free ball passage, detachablepower cable.TP 50For heavily contaminated fluids, 44 mm free ball passage, detachablepower cable.TP 65For heavily contaminated fluids, 44 mm free ball passage, detachablepower cable.TP 80For heavily contaminated fluids and faeces, 78 mm free ball passage.Explosion protection as standard, detachable power cable (singlepump station only).150 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsWilo-DrainLift WS, WBProduct DescriptionWilo-DrainLift WBConcrete shaft pumping stationType keyExample: WB 100 E/TP 40 SWB Sump pump station, concrete100 Inner diameter of shaft [cm]ETP 40 SE = Single pumpD = Double pumpSelected pump typeApplicationsMechanical building services for collection and pumping of wastewaterand sewage from– Basement floors– Air raid shelters– Underground car parksMunicipal and industrial sewage disposal. Suitable for use as a fullyassembled sump pump station in pressure drainage applications andas a collective pumping station in gravity drainage.Applicable Pump TypesTP 40 SFor heavily contaminated fluids and faeces, detachable power cable.With patented macerator:- Internally located cutters- Conically designed macerator- Absolutely reliable operationDesignWB sump pump stations are available in two design variants:Individual:Sump dimensions, inlet and discharge connections are freely selectable,and a wide range of accessories, including shaft ladders, pedestals,special paints etc. is available. For quotations for individualprojects please contact your local Wilo representativeStandard:Details on sump dimensions, inlet and discharge connections arelisted on the following data sheets. Accessories can be supplied inthe listed variants; however, modifications other than those variantsare not possible.Freight and installation are customised. Please contact your localWilo representative.The standard version is made of monolithic, statically tested, impermeablereinforced concrete elements in accordance with DIN 4281,Part 1 and DIN 1045 of class B 45 concrete with a load capacity of upto SLW 60, and has an almost sediment-free collection chamber withsilicified interior.Scope of delivery (standard version)– Steel discharge pipe– Elbow base– Chain 5 m– Guide pipe/cable– Gate valve– Check valve body– Y-piece (for dual pump plant)– Discharge connection : Plasson threaded fittings orEKS-piece– F-sleeve DN 100 for on-site cable lead-throughs and vent connectionsoffset by 180º– Cover plate with a loading capacity of up to SLW 60 with 1 or 2openings, (Ø 610 x 250 mm, for TP 150 Ø 800 x 150 mm)– 1 or 2 class B covers (Ø 610 x 150 mm,for TP 150 Ø 800 x 150 mm)– Installation and operating manualDouble pump stations are always supplied with twice the number ofabove-water couplings and fittings.Wet Sump Pumping StationsTP 50 and TP 65For heavily contaminated fluids, 44 mm free ball passage. Explosionprotection as standard, detachable power cable.STC, STS, TP 80-150For heavily contaminated fluids and sewage.As of: 06/2004 - Subject to change without prior notice151


Wet Sump Pumping StationsWilo-DrainLift WSPump Curve, Dimension DrawingsDrainLift WSWilo-DrainLift WSPump Curve, Dimension DrawingsPump chart Wilo-Drain TP (50 Hz)[m]3224Wilo-DrainTP40S, TP50, TP65, TP80For individual pump curves, refer tothe technical data for the respective pump.In accordance with EN 12056-4.6.1,a flow velocity (in the pressure line)of between 0.7 and 2.3 m/s is to bemaintained.H16TP 40S8TP 50TP 65TP 8000 20 40 60 80 100Q[m 3 /h]Dimension drawingsWilo-DrainLift WS 900 - Dimensions for sump shorteningsA430315195Ø 840Ø 740830G 1 1/2 "100405740117018008562 x DN1002 x DN150560OFFAA126045°152 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsWilo-DrainLift WSPump Curve, Dimension DrawingsWilo-DrainLift WS 1100 - Dimensions for shaft shortenings375250125G 1 1/2 "AØ 840Ø 74076510052767510951800Ø 10842 x DN100625OF FA1500AWet Sump Pumping Stations150022,5°4 x DN15045°4x90° = 360 °Wilo-DrainLift WS 900 with pumpWilo-DrainLift WS 1100 with pumpTS 40 TP 50 TP 65 TP 40 S TP 50 TP 65 TP 80 TP 40 Ssingle double single single single double single double single single single doublePump hight „Stopp“ dimension A 200 354 220 285 180 230 310 260 360 330 200 240As of: 06/2004 - Subject to change without prior notice153


Wet Sump Pumping StationsWilo-DrainLift WSAccessories for WS sump pump stationMechanical AccessoriesShaft extensions made of PE(Ø 730 x 800 mm), incl. installation accessories,seal and holding rod extension for level sensor(custom lengths available upon request).Extensions may not be connected to eachother. A maximum of 1 extension is possible pershaft.Mechanical AccessoriesSump cover made of PE"Standard" Ø 830 mm incl. non-slip profile onthe top side and two locks on the inside. Class Afor pedestrian trafficSump cover made of PE"Submersible" Ø 960 x100 mm includes nonslipprofile on the top and six stainless steellocks for locking to the outside. Class A forpedestrian trafficClamping connector made of PEfor discharge pipe connection outside of thesump– 1 1 / 2 " (Rp (JG)) with 50 mm outer Ø– 1 1 / 2 " (Rp (JG)) with 63 mm outer Ø– 2" (Rp (JG)) with 63 mm outer Ø154 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsWilo-DrainLift WBPump CurvesDrainLift WBWilo-DrainLift WBPump Curves2-pole, 50 Hz2/4-pole, 50 Hz[m]Wilo-DrainTP40S, TP50, TP65[m]70Wilo-Drain STC 80/10032602450TP40 S40H16H30STC 100STC 80208TP50TP651000 10 20 30 40 50 60[m 3 /h]0 40 80 120 160 200[m 3 /h]QQ4-pole, 50 Hz4-pole, 50 Hz[m]20Wilo-DrainSTS 80/100[m]25Wilo-DrainTP80 - TP15020H15105STS 80STS 10000 50 100 150 200Q[m 3 /h]In accordance with EN 12056-4.6.1, a flow velocity(in the pressure line) of between 0.7 and 2.3 m/s is to be maintained.H15105TP 80TP 100TP 15000 50 100 150 200 250 300 350Q[m 3 /h]Wet Sump Pumping StationsAs of: 06/2004 - Subject to change without prior notice155


Dimension drawingsPrefabricated self-contained concrete sump WB 100 – standardDuctwork forventilationDN 100 PVC-KG1400Class B KN 125650aWet Sump Pumping StationsWilo-DrainLift WBDimension DrawingsSingle pump station- WB 100 E/TP 40 S- WB 100 E/TP 50- WB 100 E/TP 65- WB 100 E/TP 80- WB 100 E/TP 100Dimension DrawingsDN 150Inlet1000DN (b)2400175010001240Ductwork for ventilationDN 100 PVC-KGInlet D N 150for PVC-KG pipeCable conduitwith wire pullDN 100 PVC-KGto be laid on site(a)Prefabricated self-contained concrete sump WB 100 – standardDuctwork forventilationDN 100 PVC-KGClass B KN 152650aDouble pump station- WB 100 D/TP 40 S- WB 100 D/TP 50- WB 100 D/TP 65Inlet10001400DN 1502400DN (b)175010001240Ductwork for ventilationDN 100 PVC-KGInlet DN 150for PVC-KG pipe(a)Cable conduitwith wire pullDN 100 PVC-KGto be laid on site156 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsWilo-DrainLift WBDimension DrawingsPrefabricated self-contained concrete sump WB 150 – standardClass B KN 125Single pump station- WB 150 E/TP 150Ductwork forventilationDN 100 PVC-KG650(a)Inlet10001900DN 1502900DN (b)225015001800Ductwork for ventilationDN 100 PVC-KGInlet DN 150for PVC-KG pipePrefabricated self-contained concrete sump WB 150 – standardDuctwork forventilationDN 100 PVC-KGClass B KN 125(a)Cable conduitwith wire pullDN 100 PVC-KGto be laid on site650(a)Double pump station- WB 150 D/TP 80- WB 150 D/TP 100Wet Sump Pumping StationsInlet10001900DN 1502900DN (b)225015001800Ductwork for ventilationDN 100 PVC-KGInlet D N 150for PVC-KG pipeCable conduitwith wire pullDN 100 PVC-KGto be laid on site(a)As of: 06/2004 - Subject to change without prior notice157


Wet Sump Pumping StationsWilo-DrainLift WBDimension DrawingsPrefabricated self-contained concrete sump WB 200 – standardDuctwork forventilationDN 100 PVC-KGClass B KN 125650(a)Double pump station- WB 200 D/TP 150Inlet10001900DN 2002900DN (b)225020002300Ductwork for ventilationDN 100 PVC-KGInlet DN 200for PVC-KG pipeCable conduitwith wire pullDN 100 PVC-KGto be laid on site(a)100E/TP 40 S100E/TP 50100E/TP 65100E/TP 80100E/TP 100Wilo-DrainLift WB...100D/TP 40 S100D/TP 50100D/TP 65150E/TP150150D/TP 80150D/TP 100min. level pump „off“ dimension A 245 510 510 315 370 245 510 510 410 315 370 410Pressure tube dimension B DN 50 DN 50 DN 65 DN 80DN100200D/TP150DN 50 DN 50 DN 65 - - - -158 As of: 06/2004 - Subject to change without prior notice


Wet Sump Pumping StationsWilo-DrainLift WBMechanical AccessoriesAccessories WB 100, 150, 200625825160Mechanical AccessoriesWB 100, WB 150:Class D cover, 400 kNØ 625 x 160 mm, weight: 164 kg8001000100WB 150 E/TP 150, WB 200:Class D cover, 400 kNØ 800 x 100 mm, weight: 160 kg1000500WB 100:Sump Extension RingsØ 1,000 x 500 mm, weight: 500 kg12401000750WB 100:Sump Extension RingsØ 1,000 x 750 mm, weight: 750 kg12401000124015001000500WB 100:Sump Extension RingsØ 1,000 x 1,000 mm, weight: 1,000 kgWB 150:Sump Extension RingsØ 1,500 x 500 mm, weight: 950 kgWet Sump Pumping Stations180015001000WB 150:Sump Extension RingsØ 1,500 x 1,000 mm, weight: 1,900 kg1800As of: 06/2004 - Subject to change without prior notice159


Notes160 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice161


Notes162 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice163


Notes164 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice165


Notes166 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice167


Notes168 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice169


Notes170 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice171


Notes172 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice173


Notes174 As of: 06/2004 - Subject to change without prior notice


NotesAs of: 06/2004 - Subject to change without prior notice175

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!