a) Air Modelb) Water ModelFigure 50. Comparison <strong>of</strong> Reduced-Scale a) Air Model and b) Water Model 3 at a W<strong>in</strong>dowOpen<strong>in</strong>g7.1.2 Two Heated Zone CaseAs described <strong>in</strong> Chapter 6, with <strong>the</strong> two heated zone case, temperature and velocitymeasurements were recorded <strong>for</strong> experiments with <strong>the</strong> stacks open and with <strong>the</strong> stacks closed.The temperature stratification <strong>in</strong> each heated zone, at <strong>the</strong> column <strong>for</strong> each level where <strong>the</strong> heatedzone connected to <strong>the</strong> atrium, and with<strong>in</strong> <strong>the</strong> atrium were measured <strong>for</strong> comparison.In <strong>the</strong> two heated zone experiments, <strong>the</strong> lower w<strong>in</strong>dows were used <strong>for</strong> both <strong>the</strong> ground floor andfirst floor heated zones. The number <strong>of</strong> stacks open was varied, from three stacks open to allthree stacks closed. This affected <strong>the</strong> enter<strong>in</strong>g and exit<strong>in</strong>g air velocities and result<strong>in</strong>gtemperature distribution <strong>in</strong> both <strong>the</strong> heated zones and with<strong>in</strong> <strong>the</strong> atrium. The air velocitymeasured us<strong>in</strong>g <strong>the</strong> hot-wire anemometer and result<strong>in</strong>g airflow through <strong>the</strong> <strong>in</strong>let and outletopen<strong>in</strong>gs are presented <strong>in</strong> Table 33. The air velocities presented are <strong>the</strong> average <strong>of</strong> all <strong>the</strong>velocities measured at each w<strong>in</strong>dow <strong>for</strong> a given floor level. A schematic <strong>of</strong> <strong>the</strong> airflow patterns<strong>for</strong> <strong>the</strong> stacks open case is shown <strong>in</strong> Figure 51.3 Data provided by S. Livermore, BP Institute, Cambridge University. December 2004.126

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!