Figure 39. Two Heated Zone ModelWith two heated zones, one above <strong>the</strong> o<strong>the</strong>r, both <strong>the</strong> effects due to radiation from <strong>the</strong> heaters <strong>in</strong>each heated zone and any heat transfer between <strong>the</strong> zones due to conduction from <strong>the</strong> ceil<strong>in</strong>g <strong>of</strong><strong>the</strong> ground floor zone through <strong>the</strong> floor <strong>of</strong> <strong>the</strong> first floor zone had to be accounted <strong>for</strong>.Experiments were carried out with <strong>for</strong> two cases, one with <strong>the</strong> stacks open and one <strong>the</strong> stacksclosed. The w<strong>in</strong>dow location was kept constant <strong>for</strong> <strong>the</strong>se cases, with only a s<strong>in</strong>gle set <strong>of</strong> lowerw<strong>in</strong>dows <strong>in</strong> each heated zone was left open.A CFD model was created to compare <strong>the</strong> results <strong>of</strong> <strong>the</strong> experimental model with a numericalmodel. As with <strong>the</strong> s<strong>in</strong>gle-heated zone case, <strong>the</strong> total heat <strong>in</strong>put was equal to <strong>the</strong> comb<strong>in</strong>edheater output. In <strong>the</strong> two-zone case, however, not only <strong>the</strong> radiation from floor to ceil<strong>in</strong>g, butalso <strong>the</strong> heat transfer between <strong>the</strong> ground floor and first floor zones had to be accounted <strong>for</strong> <strong>in</strong><strong>the</strong> model. This modification was done <strong>in</strong> a similar manner to <strong>the</strong> way it was done <strong>in</strong> <strong>the</strong> s<strong>in</strong>glezonecase. Plates were located on <strong>the</strong> ceil<strong>in</strong>g to account <strong>for</strong> <strong>the</strong> radiation to <strong>the</strong> ceil<strong>in</strong>g <strong>for</strong> eachzone, and a plate was added to <strong>the</strong> floor <strong>of</strong> <strong>the</strong> first floor zone with a low-level heat flux <strong>of</strong> 15Watts per square meter to account <strong>for</strong> <strong>the</strong> heat transfer from <strong>the</strong> ground floor zone to <strong>the</strong> firstfloor zone.110

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!