13.07.2015 Views

Methodology for the Evaluation of Natural Ventilation in ... - Cham

Methodology for the Evaluation of Natural Ventilation in ... - Cham

Methodology for the Evaluation of Natural Ventilation in ... - Cham

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

40-location card <strong>in</strong>serted <strong>in</strong>to <strong>the</strong> data-record<strong>in</strong>g device. Data could be measured anddownloaded to a computer <strong>in</strong> real time or to a designated file location on <strong>the</strong> computer. Thechannels, or locations, on <strong>the</strong> card were configured <strong>for</strong> record<strong>in</strong>g temperature measurements,us<strong>in</strong>g Type K <strong>the</strong>rmocouple wire, and an <strong>in</strong>ternal reference temperature. When <strong>the</strong> channelswere set up to record data with an <strong>in</strong>ternal reference temperature, ra<strong>the</strong>r than <strong>the</strong> external orsimulated, <strong>the</strong> measurements were all relative to one ano<strong>the</strong>r, ra<strong>the</strong>r than relative to a prescribedreference temperature or ambient reference temperature. By us<strong>in</strong>g <strong>the</strong> <strong>in</strong>ternal referencetemperature, <strong>the</strong> data collected us<strong>in</strong>g <strong>the</strong> Keithley® could be directly compared to <strong>the</strong>temperature data recorded us<strong>in</strong>g <strong>the</strong> CR10X. The Keithley® data acquisition system was set upto record data every 0.16 seconds. S<strong>in</strong>ce <strong>the</strong>re were 40 locations that were monitored at anygiven time, it took 6.4 seconds <strong>for</strong> each data set to be recorded. The average temperature over 15measurements was used as <strong>the</strong> temperature <strong>for</strong> data analysis purposes. The setup files <strong>for</strong> <strong>the</strong>Keithley® data recorder are provided <strong>in</strong> Appendix A.Thermocouples were used to measure temperatures not monitored with<strong>in</strong> <strong>the</strong> HVAC system.Type K <strong>the</strong>rmocouples were used throughout <strong>the</strong> test chamber to record temperaturemeasurements both <strong>in</strong>side and outside <strong>the</strong> scale model. The <strong>the</strong>rmocouples were <strong>the</strong>n placed on<strong>the</strong> <strong>in</strong>terior <strong>of</strong> <strong>the</strong> scaled model, <strong>of</strong>ten us<strong>in</strong>g a highly heat resistant duct tape to ensure that <strong>the</strong><strong>the</strong>rmocouple would rema<strong>in</strong> <strong>in</strong> place even when exposed to high temperatures (>70°C). In eachheated zone, six <strong>the</strong>rmocouples attached to <strong>the</strong> CR10X were placed at mid-height <strong>in</strong> each heatedzone <strong>of</strong> <strong>the</strong> model, and a <strong>the</strong>rmocouple was placed on each <strong>of</strong> <strong>the</strong> three sides <strong>of</strong> <strong>the</strong> atrium at <strong>the</strong>first floor level, and on <strong>the</strong> two sides <strong>of</strong> <strong>the</strong> second floor level. All <strong>the</strong>rmocouples were 2mm <strong>in</strong>diameter, and <strong>the</strong> junctions were coated with alum<strong>in</strong>um pa<strong>in</strong>t to reduce <strong>the</strong> effect <strong>of</strong> radiation onair temperature measurements. These <strong>the</strong>rmocouples rema<strong>in</strong>ed <strong>in</strong> place <strong>for</strong> <strong>the</strong> duration <strong>of</strong> <strong>the</strong>experiments. The <strong>the</strong>rmocouples attached to <strong>the</strong> Keithley® system were moved as neededamong different experiment configurations. These <strong>the</strong>rmocouples were primarily used to recordmore detailed temperature stratification measurements <strong>for</strong> specific areas <strong>of</strong> <strong>the</strong> model under<strong>in</strong>vestigation.Several globe anemometers were placed on <strong>the</strong> <strong>in</strong>terior <strong>of</strong> <strong>the</strong> model <strong>in</strong> order to measure <strong>the</strong><strong>in</strong>terior air velocity. The globe anemometers provide an air velocity measurement, but not <strong>the</strong>direction <strong>of</strong> airflow. The globe anemometers had silvered tips and were connected to a dataacquisition system located on <strong>the</strong> same computer as <strong>the</strong> CR10X <strong>the</strong>rmocouples. The s<strong>of</strong>twarepackage allows <strong>for</strong> <strong>in</strong>stantaneous read<strong>in</strong>gs us<strong>in</strong>g <strong>the</strong> globe anemometers.Several pieces <strong>of</strong> hand-held equipment were used to ga<strong>the</strong>r data that are more detailed on <strong>the</strong>reduced-scale model and <strong>the</strong> surround<strong>in</strong>g conditions. Hot-wire anemometers were used to takeair velocity measurements at <strong>in</strong>let and outlet open<strong>in</strong>gs. Due to <strong>the</strong> geometry <strong>of</strong> <strong>the</strong> open<strong>in</strong>gs, anaverage velocity was taken over <strong>the</strong> open<strong>in</strong>g area. The hot-wire anemometer, with a probe size<strong>of</strong> 1mm diameter, had precision <strong>of</strong> 0.1 m/s. An <strong>in</strong>frared temperature sensor was used to ga<strong>the</strong>rdata on <strong>the</strong> surface temperatures with<strong>in</strong> <strong>the</strong> model and surround<strong>in</strong>g <strong>the</strong> model to assure that<strong>the</strong>rmal radiation effects ei<strong>the</strong>r between surfaces with<strong>in</strong> <strong>the</strong> model or between <strong>the</strong> exteriorsurfaces <strong>of</strong> <strong>the</strong> model and <strong>the</strong> test chamber did not distort experimental results.Additionally, flow visualization equipment was used to determ<strong>in</strong>e <strong>the</strong> airflow patterns with<strong>in</strong> <strong>the</strong>model qualitatively and to ensure that <strong>the</strong>re were no significant leaks <strong>in</strong> <strong>the</strong> model. Draeger104

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!