Subsea Control Systems - Weatherford International

Subsea Control Systems - Weatherford International

Subsea Control Systems - Weatherford International

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>Subsea</strong> <strong>Control</strong> <strong>Systems</strong><br />

<strong>Weatherford</strong> <strong>International</strong> Ltd.<br />

515 Post Oak Blvd., Suite 600<br />

Houston, Texas 77027 USA<br />

Tel: 713-693-4000<br />

weatherford.com<br />

Production Optimization<br />

<strong>Weatherford</strong> is a leading provider of multiplex subsea, surface<br />

wellhead, and integrated control systems for enhancing oil and gas<br />

production. The electro-hydraulic multiplex subsea control system is<br />

a modular design concept that incorporates well-proven technology<br />

and qualified components to optimize production and minimize costs.<br />

<strong>Weatherford</strong>’s integrated system provides the requisite monitoring,<br />

control, and shutdown functions by means of multiplexed electrohydraulic<br />

control, using communications on power between a surface<br />

master control station (MCS) and subsea control module (SCM) via<br />

a composite services umbilical, and appropriate subsea distribution<br />

unit(s).<br />

Communications between surface and subsea are by means of a<br />

LonWorks ® power-line carrier. Communications can be adapted to suit on power, twisted pair, or fiber<br />

optic, depending on configuration.<br />

The system is designed for deployment and intervention by means of a remotely operated vehicle (ROV),<br />

assisted guideline, and guideline-less running tool (available for rental with ROV assistance in very deep<br />

water). The ROV features a simple sliding-plate design with locking down mechanism. A similar module is<br />

also available for diver installation.<br />

The subsea electronics module (SEM) is surface removable and replaceable without the need to disturb<br />

the module’s hydraulics chamber. Electric and hydraulic connections are made with low-force connectors<br />

mounted on the base of the unit; they connect when the unit is locked into place.<br />

The SCM housing is filled with dielectric fluid prior to installation and is pressure-compensated to<br />

safeguard against over or under pressurization. The SCM housing is fabricated from structural steel<br />

manufactured to BS EN 10 025 Grade Fe430C or Fe510 D1/D2 and finish painted to <strong>Weatherford</strong>’s<br />

standard subsea paint specifications. All hydraulic and electric couplings are manufactured from 316<br />

stainless steel (SS) or higher grade materials.<br />

The hydraulic system consists of self-latching, solenoid-operated, shear-seal, directional-control<br />

valves, mounted on a SS block manifold, with single or dual hydraulic supplies, depending on client’s<br />

specifications. Electrically held-open valves also can be mounted in the unit for emergency shutdown<br />

(ESD) system functionality, if required.<br />

Individual high-pressure (HP) and low-pressure (LP) hydraulic supply filters are mounted within the<br />

control module to maintain fluid cleanliness specifications. Both types of hydraulic supply filters have<br />

pressure transducers to indicate system pressure within the control module.<br />

The tree valve hydraulic actuator’s inferred status is sensed by individual pressure transducers, integral<br />

to the directional control valves, which relay the function line pressures to topside, where they may be<br />

displayed on the master control station (MCS) screen; they can also be made available to the distributed<br />

control system (DCS) platform control system.<br />

© 2008 <strong>Weatherford</strong>. All rights reserved. 5347.00


<strong>Subsea</strong> <strong>Control</strong> <strong>Systems</strong><br />

<strong>Subsea</strong> <strong>Control</strong> Module (SCM)<br />

<strong>Weatherford</strong> <strong>International</strong> Ltd.<br />

515 Post Oak Blvd., Suite 600<br />

Houston, Texas 77027 USA<br />

Tel: 713-693-4000<br />

weatherford.com<br />

(2)<br />

Production Optimization<br />

An accumulator can be accommodated within the control module to help prevent pressure drop during<br />

valve operations on large step outs; alternatively, separate subsea-accumulator modules can be provided<br />

to maintain local pressure levels.<br />

Electronics<br />

The subsea electronics are enclosed in a 1-atmosphere dry nitrogen-purged housing located within the<br />

main SCM housing, with proprietary penetrators to allow connection to the SCM. Within the SEM housing,<br />

ambient temperature and pressure are continually monitored; an alarm may be sent to the MCS should<br />

abnormal conditions arise.<br />

The SCM incorporates dual 230-Vac at 50 Hz power supplies and uses a super-imposed, high-frequency<br />

carrier on each power line, along with the LonWorks network communications protocol, enabling control<br />

and monitoring via either or both power/communications lines.<br />

The SEM will operate with a twisted-pair communication line and separate power supply, or with a powerline<br />

carrier. Using a power-line carrier reduces umbilical costs and also provides performance benefits.<br />

The subsea electronic control and communication system is based around the neuron 3150 processor<br />

chip, with the surface being PC/PLC based. Responses from the surface or subsea units are propagated<br />

back to the PCS via a ModBus ® -compliant serial channel from the MCS. The SEM also runs diagnostics<br />

showing the state of all power supplies and communications. Bad communications are detected and<br />

rejected to prevent incorrect data from causing unpredictable actions.<br />

Diagnostic tools and displays are available to the operators via the topside MCS.<br />

Unit Characteristics<br />

• Four HP hydraulic outputs<br />

• LP hydraulic outputs (22)<br />

• Dual HP hydraulic inputs via shuttle valve<br />

• Dual LP hydraulic inputs via shuttle valve<br />

• HP-ESD valve<br />

• LP-ESD valve<br />

• Directly mounted digital control valves to single manifold block<br />

•<br />

HP and LP vents to sea or closed loop returns<br />

© 2008 <strong>Weatherford</strong>. All rights reserved. 5347.00


<strong>Subsea</strong> <strong>Control</strong> <strong>Systems</strong><br />

<strong>Subsea</strong> <strong>Control</strong> Module (SCM) (continued)<br />

<strong>Weatherford</strong> <strong>International</strong> Ltd.<br />

515 Post Oak Blvd., Suite 600<br />

Houston, Texas 77027 USA<br />

Tel: 713-693-4000<br />

weatherford.com<br />

(3)<br />

Production Optimization<br />

External Standards<br />

• Carbon steel-fabricated housing, painted to standard subsea paint specification<br />

• Installation and intervention by ROV-assisted running tool or diver onto mounting base<br />

• Dielectric fluid filled pressure compensated housing and atmospheric SEM housing<br />

• Designed for use up to 10,000 ft (3,000 m) of water<br />

• 1.5-atmosphere nitrogen-filled electronics housing with temperature monitoring<br />

• Dual HP and LP supplies, incorporating individual hydraulic supply line filters with B3 = 200 rated<br />

elements<br />

• <strong>Control</strong> of hydraulic valve actuators by stainless steel body, sheer seal-type solenoid valves<br />

• Earth strap for bonding and low resistance connection to the module mounting base on the manifold<br />

cathodic protection system<br />

• Connection points legibly identified by proprietary laminated nameplates<br />

• Stand-alone sacrificial anodes for cathodic protection are provided, based on isolation for six months on<br />

the seabed<br />

•<br />

Two outgoing electro-hydraulic ROV/diver stabplates, both mounted on SCM mounting base<br />

© 2008 <strong>Weatherford</strong>. All rights reserved. 5347.00


<strong>Subsea</strong> <strong>Control</strong> <strong>Systems</strong><br />

Specifications<br />

Environmental data<br />

Water depth - LAT (ft/m)<br />

Operating temperature Range<br />

9,843<br />

3,000<br />

Surface unit (°F/°C)<br />

32° to 104°<br />

0° to 40°<br />

<strong>Subsea</strong> unit (°F/°C)<br />

32° to 104°<br />

0° to 40°<br />

Shock<br />

NES 1004 ISS 2 DS 20 + Defense - Standard<br />

07-55-test. A3 up to drop test<br />

Vibration<br />

<strong>Subsea</strong> equipment design<br />

NES 1004 ISS 2 DS 25<br />

5 to 150 Hz at 2-g for 6 hours<br />

Design life 25 years<br />

Intervention ROV deployment and intervention<br />

SCM size (in./mm)<br />

33 × 33 × 30 high<br />

(excluding mounting base)<br />

850 × 850 × 750 high<br />

SCM weight<br />

In air (lb/kg)<br />

1,764<br />

800<br />

In water (approximate) (lb/kg)<br />

1,323<br />

600<br />

SCM housing Pressure-compensated, dielectric-fluid filled<br />

Mounting<br />

System pressures and fluid<br />

<strong>Subsea</strong> tree or manifold structure<br />

(ROV to AP1 17H or diver)<br />

High pressure (psi/bar)<br />

14,997 MWP<br />

1,034 MWP<br />

Low pressure (psi/bar)<br />

3,002 MWP<br />

207 MWP<br />

<strong>Control</strong> fluid (standard)<br />

Water-based biodegradable, open-loop<br />

or petroleum-based, synthetic-mineral oil<br />

<strong>Control</strong> fluid cleanliness NAS 1638 Class 6<br />

Supply filtration<br />

Electrical<br />

Integral single B3 - 200 rating elements (3-micron)<br />

Power supply 230 or 480 Volts, 60 Hz single-phase supply<br />

Communications Fiber or twisted pair<br />

LonWorks and ModBus are trademarks of their respective owners.<br />

<strong>Weatherford</strong> <strong>International</strong> Ltd.<br />

515 Post Oak Blvd., Suite 600<br />

Houston, Texas 77027 USA<br />

Tel: 713-693-4000<br />

weatherford.com<br />

(4)<br />

Production Optimization<br />

<strong>Weatherford</strong> products and services are subject to the Company’s standard terms and conditions, available<br />

on request or at weatherford.com. For more information contact an authorized <strong>Weatherford</strong> representative.<br />

Unless noted otherwise, trademarks and service marks herein are the property of <strong>Weatherford</strong>. Specifications<br />

are subject to change without notice. <strong>Weatherford</strong> sells its products and services in accordance with the<br />

terms and conditions set forth in the applicable contract between <strong>Weatherford</strong> and the client.<br />

© 2008 <strong>Weatherford</strong>. All rights reserved. 5347.00

Hooray! Your file is uploaded and ready to be published.