instruments and accessories for apc - Elmed

instruments and accessories for apc - Elmed instruments and accessories for apc - Elmed

ARGON PLASMA COAGULATIONI n s t r u m e n t s a n d a c c e s s o r i e sINSTRUMENTS AND ACCESSORIES FOR APC


LegendImportant notesThe authors <strong>and</strong> ERBE Elektromedizin GmbH have taken the greatest possible care whilecompiling the catalogue with electro surgical <strong>accessories</strong>. Nevertheless, it is impossible toexclude the possibility that errors may be contained herein.The in<strong>for</strong>mation <strong>and</strong> recommendations given here may not be construed as constituting anybasis <strong>for</strong> any claims against ERBE Elektromedizin GmbH. Should legal regulations stipulateliability, such liability shall be limited to intentional misconduct or gross negligence.The data on the use of <strong>instruments</strong> is based on clinical ex perience. Medical science is subjectto a process of perman ent change based on research <strong>and</strong> clinical experience. There<strong>for</strong>e theproducts are subject to alterations in design <strong>and</strong> technique. Because of production tolerancesdimensions in the catalogue may marginally differ.We confirm that none of our products contain latex, except the rubber straps,Art. No. 20592-009 <strong>and</strong> 20592-011.Please read carefully the corresponding notes on use be<strong>for</strong>e using any instrument.Further product in<strong>for</strong>mationPackaging unit= 5 4 kVpMax. electrical capacityNotes on usemax 95 °C30191-682 max 134 °CTemperature <strong>for</strong> cleaning in washer disinfectorTemperature <strong>for</strong> sterilization in autoclaveSingle-use productSTERILE RSTERILE RSTERILE EOSterile packagingManual cleaning <strong>and</strong> disinfection02 www.erbe-med.com


ContentsArgon plasma coagulationInstruments <strong>for</strong> APCFiAPC probes, single use 04Flexible APC probes, reusable 07Flexible APC probes, single use 09APC applicators <strong>for</strong> APC connecting cables 11APC applicators <strong>for</strong> APC h<strong>and</strong>les 14Accessories <strong>for</strong> APCAPC connecting cables 17APC h<strong>and</strong>les 18APC irrigation adapters 19APC ignition test adapters 19OverviewAPC probe orAPC applicatorAPC h<strong>and</strong>le Irrigation adapter Connecting cableElectrosurgical unitArgon plasma coagulationCleaningAPC probe or APC applicatorLuer Lock connectorwww.erbe-med.com03


Instruments <strong>for</strong> APCBeam <strong>for</strong>msAxial beamASide Fire Wide BeamSWSide Fire Conical BeamSCCircumferential BeamCFiAPC probes, single useFiAPC probe 1500 A, ø 1.5 mm, flexible, length 1.5 mwith instrument recognition <strong>and</strong> integrated filter, e.g. <strong>for</strong> bronchoscopyNo. 20132-220= 10 4.3 kVp30132-344 STERILE EOFiAPC probe 2200 A, ø 2.3 mm, flexible, length 2.2 mwith instrument recognition <strong>and</strong> integrated filterNo. 20132-221= 10 4.3 kVp30132-344 STERILE EO04 www.erbe-med.com


Instruments <strong>for</strong> APCFiAPC probes, single useFiAPC probe 2200 A, ø 3.2 mm, flexible, length 2.2 mwith instrument recognition <strong>and</strong> integrated filterNo. 20132-222= 10 4.3 kVp30132-344 STERILE EOFiAPC probe 3000 A, ø 2.3 mm, flexible, length 3 mwith instrument recognition <strong>and</strong> integrated filterNo. 20132-223= 10 4.3 kVp30132-344 STERILE EOFiAPC probe 2200 SC, ø 2.3 mm, flexible, length 2.2 mwith instrument recognition <strong>and</strong> integrated filterNo. 20132-224= 10 4.3 kVp30132-344 STERILE EOwww.erbe-med.com05


Instruments <strong>for</strong> APCFiAPC probes, single useFiAPC probe 2200 C, ø 2.3 mm, flexible, length 2.2 mwith instrument recognition <strong>and</strong> integrated filterNo. 20132-225= 10 4.3 kVp30132-344 STERILE EOFiAPC probe 3000 A, ø 1.5 mm, flexible, length 3 mwith instrument recognition <strong>and</strong> integrated filter,e.g. <strong>for</strong> double-balloon enteroscopyNo. 20132-226= 10 4.3 kVp30132-344 STERILE EOAdapter <strong>for</strong> FiAPC probes<strong>for</strong> connection with APC 2 / APC 300No. 20132-227= 1 4.3 kVpmax 95 °C30132-346 max 138 °C06 www.erbe-med.com


Instruments <strong>for</strong> APCFlexible APC probes, reusableAPC probe 1500 A, ø 1.5 mm, flexible, length 1.5 mNo. 20132-183= 1 4 kVpmax 95 °Cwith instrument recognition, e.g. <strong>for</strong> bronchoscopy30132-326 max 138 °CAPC probe 1000 A, ø 2.3 mm, flexible, length 1 mNo. 20132-178= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °CAPC probe 2200 A, ø 2.3 mm, flexible, length 2.2 mNo. 20132-177= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °CAPC probe 3000 A, ø 2.3 mm, flexible, length 3 mNo. 20132-179= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °CAPC probe 2200 SW, ø 2.3 m, flexible, length 2.2 mNo. 20132-180= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °Cwww.erbe-med.com07


Instruments <strong>for</strong> APCFlexible APC probes, reusableAPC probe 2200 SC, ø 2.3 mm, flexible, length 2.2 mNo. 20132-181= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °CAPC probe 2200 A, ø 3.2 mm, flexible, length 2.2 mNo. 20132-182= 1 4.3 kVpmax 95 °Cwith instrument recognition30132-326 max 138 °CAPC connecting cable/irrigation adapter Length Piece No.Connecting cable <strong>for</strong> flexible APC probes,2.5 m 1 20132-158APC 2, APC 300Irrigation adapter <strong>for</strong> flexible APC probes toLuer Lock connector5 20132-203Bacteriological filter set, APC 2, APC 300,0.2 µm, sterile50 20132-05908 www.erbe-med.com


Instruments <strong>for</strong> APCFlexible APC probes, single useAPC probe 1500 A, ø 1.5 mm, flexible, length 1.5 mNo. 20132-155= 10 4 kVpwith instrument recognition, e.g. <strong>for</strong> bronchoscopy30132-309 STERILE EOAPC probe 3000 A, ø 1.5 mm, flexible, length 3 mNo. 20132-212= 10 4 kVpwith instrument recognition,e.g. <strong>for</strong> double-balloon enteroscopy30132-309 STERILE EOAPC probe 2200 A, ø 2.3 mm, flexible, length 2.2 mNo. 20132-156= 10 4.3 kVpwith instrument recognition30132-309 STERILE EOAPC probe 3000 A, ø 2.3 mm, flexible, length 3 mNo. 20132-166= 10 4.3 kVpwith instrument recognition30132-309 STERILE EOAPC probe 2200 SC, ø 2.3 mm, flexible, length 2.2 mNo. 20132-167= 10 4.3 kVpwith instrument recognition30132-309 STERILE EOwww.erbe-med.com09


Instruments <strong>for</strong> APCFlexible APC probes, single useAPC probe 2200 C, ø 2.3 mm, flexible, length 2.2 mNo. 20132-186= 10 4.3 kVp30132-309 STERILE EOwith instrument recognitionAPC probe 2200 A, ø 3.2 mm, flexible, length 2.2 mNo. 20132-157= 10 4.3 kVpwith instrument recognition30132-309 STERILE EOAPC connecting cable/irrigation adapter Length Piece No.Connecting cable <strong>for</strong> flexible APC probes,2.5 m 1 20132-158APC 2, APC 300Bacteriological filter set, APC 2, APC 300,0.2 µm, sterile50 20132-05910 www.erbe-med.com


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC connecting cablesColor codesSANlateral openingaxial openingwith needleAPC applicator 110 A, ø 2.3 mm, rigid, length 110 mmNo. 20132-107= 1 4.3 kVpmax 95 °C30132-245 max 138 °CAPC applicator 240 A, ø 2.3 mm, rigid, length 240 mmNo. 20132-111= 1 4.3 kVpmax 95 °C30132-245 max 138 °CAPC applicator 300 A, ø 2.3 mm, rigid, length 300 mmNo. 20132-113= 1 4.3 kVpmax 95 °C30132-245 max 138 °Cwww.erbe-med.com11


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC connecting cablesAPC applicator 500 A, ø 2.3 mm, rigid, length 500 mmNo. 20132-116= 1 4.3 kVpmax 95 °C30132-245 max 138 °CAPC applicator 110 SC, ø 2.3 mm, rigid, length 110 mmNo. 20132-106= 1 4.3 kVpmax 95 °C30132-245 max 138 °CProtection tongue <strong>for</strong> APC applicator 20132-106, elasticsilicone= 10No. 20132-129max 95 °C30132-270 max 134 °CAPC applicator 240 SC, ø 2.3 mm, rigid, length 240 mmNo. 20132-110= 1 4.3 kVpmax 95 °C30132-245 max 138 °C12 www.erbe-med.com


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC connecting cablesAPC applicator 110 N, ø 2.3 mm, rigid, length 110 mmNo. 20132-109= 1 4.3 kVpmax 95 °C30132-245 max 138 °Cwith exposed needle 6 mm, e.g. <strong>for</strong> tonsillectomyAPC applicator 116 SC, ø 2.3 mm, rigid, length 116 mmNo. 20132-126= 1 4.3 kVpmax 95 °C30132-245 max 138 °CAPC connecting cable/irrigation adapter Length Piece No.Connecting cable <strong>for</strong> APC applicators,2.5 m 1 20132-046APC 2, APC 300Irrigation adapter <strong>for</strong> APC applicatorswith Luer Lock5 20132-095www.erbe-med.com13


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC h<strong>and</strong>lesAPC applicator, ø 5 mm, rigid, length 25 mmNo. 20132-031= 1 4.3 kVpmax 95 °C30132-041 max 138 °CAPC applicator, ø 5 mm, rigid, length 100 mmNo. 20132-032= 1 4.3 kVpmax 95 °C30132-041 max 138 °CAPC applicator, ø 5 mm, rigid, length 320 mmNo. 20132-034= 1 4.3 kVpmax 95 °C30132-041 max 138 °CAPC applicator, ø 5 mm, rigid, length 320 mmNo. 20132-084= 1 4.3 kVpwith hook electrodemax 95 °C30132-041 max 138 °CAPC applicator, ø 5 mm, rigid, length 35 mmNo. 20132-054= 1 4.3 kVpmax 95 °C30132-041 max 138 °Cwith adjustable needle electrode14 www.erbe-med.com


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC h<strong>and</strong>lesAPC applicator, ø 5 mm, rigid, length 35 mmNo. 20132-057= 1 4.3 kVpmax 95 °C30132-041 max 138 °Cwith adjustable spatulaAPC applicator, ø 5 mm, rigid, length 100 mmNo. 20132-044= 1 4.3 kVpmax 95 °C30132-041 max 138 °Cwith adjustable needle electrodeAPC applicator, ø 5 mm, rigid, length 100 mmNo. 20132-056= 1 4.3 kVpmax 95 °C30132-041 max 138 °Cwith adjustable spatulaAPC applicator, ø 5 mm, rigid, length 220 mmNo. 20132-211= 1 4.3 kVpmax 95 °C30132-332 max 138 °Cwith adjustable needle electrodeAPC applicator, ø 5 mm, rigid, length 320 mmNo. 20132-133= 1 4.3 kVpmax 95 °C30132-332 max 138 °Cwith adjustable spatulawww.erbe-med.com15


Instruments <strong>for</strong> APCAPC applicators <strong>for</strong> APC h<strong>and</strong>leAPC applicator, ø 6 mm, flexible, length 100 mmNo. 20132-033= 1 4.3 kVpmax 95 °C30132-041 max 138 °CAPC applicator, ø 6 mm, flexible, length 200 mmNo. 20132-140= 1 4.3 kVpmax 95 °C30132-041 max 138 °CAPC applicator, ø 6 mm, tip flexible, length 320 mmNo. 20132-040= 1 4.3 kVpmax 95 °C30132-041 max 138 °C16 www.erbe-med.com


Accessories <strong>for</strong> APCAPC applicators <strong>for</strong> APC h<strong>and</strong>lesAPC h<strong>and</strong>les/irrigation adapters Length Piece No.VIO APC ReMode h<strong>and</strong>le, APC 2 3 m 1 20132-200VIO APC h<strong>and</strong>le, APC 2 3 m 1 20132-201VIO APC h<strong>and</strong>le, APC 2, APC 300 3 m 1 20132-043Irrigation adapter <strong>for</strong> APC applicatorswith Luer Lock5 20132-087APC connecting cablesConnecting cable <strong>for</strong> flexible APC probes, APC 2 / VIO, APC 300 / ICC, length 2.5 mNo. 20132-158= 1max 95 °C30132-363 max 138 °CConnecting cable <strong>for</strong> APC applicators, APC 2 / VIO, APC 300 / ICC, length 2.5 mNo. 20132-046= 1max 95 °C30132-363 max 138 °Cwww.erbe-med.com17


Accessories <strong>for</strong> APCAPC h<strong>and</strong>lesVIO APC ReMode h<strong>and</strong>le with 3 buttons <strong>for</strong> APC 2, with connecting cable 3 mwith instrument recognitionNo. 20132-200= 1 5 kVpmax 95 °C30132-301 max 138 °CVIO APC h<strong>and</strong>le with 2 buttons <strong>for</strong> APC 2, with connecting cable 3 mwith instrument recognitionNo. 20132-201= 1 5 kVpmax 95 °C30132-301 max 138 °CAPC h<strong>and</strong>le with 2 buttons, APC 2 / VIO, APC 300 / ICC, with connecting cable 3 mwith instrument recognitionNo. 20132-043= 1 4 kVpmax 95 °C30132-357 max 138 °C18 www.erbe-med.com


Accessories <strong>for</strong> APCAPC irrigation adaptersIrrigation adapter <strong>for</strong> flexible APC probes with Luer-Lock<strong>for</strong> APC applicators with APC connecting cables 20132-046= 5No. 20132-095max 95 °C30132-209 max 138 °CIrrigation adapter <strong>for</strong> flexible APC probes with Luer-Lock<strong>for</strong> APC probes with APC connecting cable 20132-158= 5No. 20132-203max 95 °C30132-209 max 138 °CIrrigation adapter <strong>for</strong> APC applicators with Luer Lock<strong>for</strong> APC applicators with APC h<strong>and</strong>les= 5No. 20132-087max 95 °Cmax 138 °CAPC ignition test adaptersAPC ignition test adapter <strong>for</strong> VIO, ICC, St<strong>and</strong>ard (NE 6 mm)No. 20183-070= 1max 95 °C30183-126 max 134 °CAPC ignition test adapter <strong>for</strong> VIO, ICC, International (NE 2-Pin)No. 20183-071= 1max 95 °C30183-126 max 138 °Cwww.erbe-med.com19


ELECTROSURGERYVESSEL SEALINGARGON PLASMA COAGULATIONCRYO SURGERYWATERJET SURGERYERBE Elektromedizin GmbHWaldhoernlestrasse 1772072 TuebingenGermanyPhone +49 7071 755-0Fax +49 7071 755-179info@erbe-med.comwww.erbe-med.com85100-169 10.13 © ERBE Elektromedizin GmbH 2013