<strong>HySense</strong> <strong>QT</strong> <strong>106</strong>CAN turbine volume flow sensorA version has been adapted for the CAN bus based on our precise and proven measuringturbine with inside thread connection according to DIN ISO 228.The turbines are factory calibrated for mineral oil at 30 cSt. Other calibration viscositiesare available.QualitiesMeasuring principlevolume fl owViscosity rangesee order dataMedium temperature max. +120 °CEnvironmental temperature -20 ... +85 °CStorage temperature -20 ... +85 °COutput signalCANopenSupply voltage Ub8.5 ... 30 VDCElectrical measuring connector 5 pole device connector, M12 x 1Protection type (EN 60529 / IEC 529) IP 67 (screwed)Tightening torque10 Nm (± 2 Nm)Calibration viscosity30 mm²/s (cSt)Material turbine casing Aluminium AlZnMgCu 1,5Material turbine wheel1.4122 (for measuring range 1,0 ... 10 l/min)1.0718 (for all other measuring ranges)Material sealingsFKMMaterial sensor casing 3.1645Current consumptionmax. 50 mA @ 24 VDCInterfaceCANopen (CIA-DS-301)CAN standard2.0A (opt. 2.0B)Transmission rate20 ... 1.000 kBit/sMeasured frequency (Hz) bytes 0 ... 3Measured volume fl ow (l/min) bytes 4 ... 7Resolutionthree decimal placesSuitable measuring cableCAN cableU31C7-01-35.030EN • 2009/05 • 1/4Pin assignment CANopen 2.0A4 3Pin 1 = CAN_SHLDPin 2 = CAN_V+5Pin 3 = CAN_GND1 2Pin 4 = CAN_HPin 5 = CAN_L<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com


<strong>HySense</strong> <strong>QT</strong> <strong>106</strong>Measuring range Max. working pressure Viscosity range Error limit Weight Order numberl/min bar MPa mm²/s (cSt) of current value g1 ... 10 420 42 1 ... 60 ± 1.0 % 671 31C7-01-35.0302 ... 75 420 42 1 ... 100 ± 0.5 % 859 31C7-70-35.0309 ... 300 420 42 1 ... 100 ± 0.5 % 1,190 31C7-71-35.03016 ... 600 350 35 1 ... 100 ± 0.5 % 1,488 31C7-72-35.030<strong>QT</strong> <strong>106</strong>AB~ 94C0,5* 0,5*GGA MINIMESS ® p/T test point for pressure andtemperature, series 1620B inductive sensor / amplifi erC MINIMESS ® test point, series 1620* depth of spot faceSWLMeasuring range SW L Gl/minmm1 ... 10 41 120 ISO 228-G¼U31C7-01-35.030EN • 2009/05 • 2/42 ... 75 46 130 ISO 228-G 3 /49 ... 300 55 150 ISO 228-G116 ... 600 60 174 ISO 228-G1¼<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com


<strong>HySense</strong> <strong>QT</strong> <strong>106</strong>Q = 1.0 ... 10 l/minQ = 7.5 ... 75 l/min4.5dp (bar)70 cSt9.0dp (bar)70 cSt3.046 cSt6.046 cSt1.530 cSt3.030 cSt002Q (l/min)4 68100015Q (l/min)30 456075Q = 9 ... 300 l/minQ = 16 ... 600 l/min9.0dp (bar)46 cSt70 cSt6.0dp (bar)46 cSt70 cSt6.030 cSt4.030 cSt3.02.00060Q (l/min)120 180 240 30000120Q (l/min)240 360 480 600U31C7-01-35.030EN • 2009/05 • 3/4<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com


NotesU31C7-01-35.030EN • 2009/05 • 4/4<strong>Hydrotechnik</strong> GmbH Holzheimer Str. 94-96D-65549 Limburg • GermanyPhone +49 (0) 6431 4004-0Fax +49 (0) 6431 45308www.hydrotechnik.cominfo@hydrotechnik.com