STRESS exercise testing systemmortara’snextgenerationstressexercisetestingsystemp r o d u c t f e a t u r e s• Windows Operating System –X-<strong>Scribe</strong> ® <strong>II</strong> provides an intuitive user interface with flexibleconfigurations to facilitate ease-of-use.• Complete ST Presentation –In addition to continuous ST trends, the X-<strong>Scribe</strong> <strong>II</strong> presents STlevel and slope for all 12 average complexes and auto-comparisonwith reference complexes which can be edited both during andafter the procedure.• Wireless ECG Acquisition Option –The X12+ digitally transmits diagnostic quality 12-lead ECG datawithout the need for a conventional tethered patient cable.• Source Consistency Filter –Mortara’s patented Source Consistency Filter reduces noise andbaseline artifact while preserving a diagnostic quality ECG signal.• Beat By Beat <strong>Rev</strong>iew Mode –Post-test playback allows for full disclosure review of the entire test.• Report Export and Network Option –Non-Proprietary PDF technology is used to create a portable electronicfile that can be e-mailed or transferred across a network for convenientreview or printing.


STRESS exercise testing systemMortara Instrument, Inc.7865 North 86th StreetMilwaukee, WI 53224Tel: 414.354.1600Tel: 800.231.7437Service: 888.MORTARAFax: 414.354.4760Mortara Rangoni Europe, Srl(European Headquarters, Italy)Via Oradour 740016 S. Giorgio di Piano, BOTel: +39.051.6654311Fax: +39.051.6651012Mortara Instrument GmbH(Germany)Kaninenberghöhe 5045136 EssenTel: +49.201.268311Fax: +49.201.268313Mortara Instrument B.V.(The Netherlands)H. Dunantplein 63731 CL De BiltPostbus 1313720 AC BilthovenTel: +31.30.2205050Fax: +31.30.2201531X - S c r i b e ® I I s y s t e mFeatureSpecificationsOperating SystemWindows Input ChannelsSimultaneous acquisition of all 12 leadsStandard Leads Acquired I, <strong>II</strong>, <strong>II</strong>I, aVR, aVL, aVF, V1, V2, V3, V4, V5, V6Display Multiple user definable format options on a 19"flat panel color monitor 1280 x 1024 resolution.Exercise Equipment Digital serial interface to treadmill or ergometerInterfaceAutomatic Blood Pressure Optional interface to external automaticMeasurement Option BP deviceInput Dynamic Range Meet or exceed the requirements ofElectrode Tolerance ANSI/AAMI EC11Common Mode RejectionFrequency ResponseDigital Sampling Rate 10,000 s/sec/channel used for pacemaker spikedetection, 500 s/sec/channel used for recordingand analysis.Network OptionOptional Network interface for data transfer andprinting across your local network.Device Classification Class I, Type CF defibrillator proof applied parts.Printer Options High speed laser printer or thermal array 200dots per inch.Data AcquisitionDirect connect or wireless connection using 608 or2500 MHz X12+ transmitter.Final Report Export Thermal array, laser, or network print capabilitywith user selectable print options.External OutputTTL and analog output.Power Requirements 100-240 VAC at 50/60 Hz*Specifications subject to change without notice.s t a n d a r d a c c e s s o r i e sRef: 9513-008-01-<strong>ENG</strong> <strong>Rev</strong> 5• System Transport Cart• Patient Cable Belt• User Manual• Short Form Instruction Card• Monitoring Hookup KitWarranty and ServiceMortara Instrument is committedto the highest level of customersupport. Please contact us for theprogram which will be best suitedfor your needs.http://www.mortara.comISO 13485 Certified

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!