12.07.2015 Views

NGC-30 - Pentair Thermal Management

NGC-30 - Pentair Thermal Management

NGC-30 - Pentair Thermal Management

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

H N CH N C B AH N CH N C B AH N CH N C B A<strong>NGC</strong>-<strong>30</strong>Self-RegulatingCablesTypical Configurations for the DigiTrace <strong>NGC</strong>-<strong>30</strong>Multi-panel Configuration with RMM2 Module• Multiple panels can be gangedtogether for control using a singleUser Interface Terminal.• Communications is accomplishedusing RS-485 wiring.• Up to 260 heat trace circuits can besupported using this architecture.• DigiTrace Supervisor Softwareinterfaces with the User InterfaceTerminal via RS-485 or 10/100BaseTEthernet.Multi-panel Configuration with PLI and RMM2 Modules• Multiple panels can be gangedtogether for control using a singleUser Interface Terminal.• Communications is accomplishedusing RS-485 wiring.• Up to 260 heat trace circuits can besupported using this architecture.• Up to 1040 temperature inputs canbe monitored with one <strong>NGC</strong>-UIT2.• Up to 127 SES/SPC transmitters or255 700-TT transmitters per PLI andup to 4 PLI modules per <strong>NGC</strong>-<strong>30</strong>controllers for control ormonitoring.• 700-TT and SES/SPC Transmitterscan be used in any combination inthe same multi-panel configurationsystem using one <strong>NGC</strong>-UIT2.• The 700-TT and SES/SPC Transmitterscannot be used on the samePLI module. At least two PLI modulesare required if a combination of700-TT and SES/SPC transmittersare used.<strong>NGC</strong>-UIT2<strong>NGC</strong>-UIT2SES/SPCPanelPanelRS-485RS-485PanelPLI PLI PLIPanelPanelPanelRMM2RemotemonitoringmoduleRMM2RemotemonitoringmoduleReplacement ComponentsDescription Catalog number Part numberUser Interface TerminalUser Interface Terminal<strong>NGC</strong>-UIT2-ORD 10332-013Nonhazardous (Unclassified) Locations; indoors or outdoors,panel mountingUser Interface Terminal<strong>NGC</strong>-UIT2-HAZ 10332-022Nonhazardous (Unclassified) and Hazardous Locations; indoorsor outdoors, panel mountingUser Interface Terminal with NEMA 4 EnclosureNonhazardous (Unclassified) Locations; indoors or outdoor,remote stand-alone mounting<strong>NGC</strong>-UIT2-ORD-R 10332-016SES/SPCSES/SPCPower-LimitingCablesMineral InsulatedCablesLonglineHeatingRTB TubingBundlesTank Heating Snow and Ice Control andMonitoringHeat-TracePanelsEngineeredProductsSteam-TracingSystemsTechnical DataSheetsTHERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/139 / 12Appendixes

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!