12.07.2015 Views

NGC-30 - Pentair Thermal Management

NGC-30 - Pentair Thermal Management

NGC-30 - Pentair Thermal Management

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

<strong>NGC</strong>-<strong>30</strong>Typical Configurations for the DigiTrace <strong>NGC</strong>-<strong>30</strong>Individual Controls with Ground-fault Trip/Current/Temperature Monitoring• Monitors ground-fault current andalarms/trip control contactor uponfault• Monitors heater current and alarmsupon low or high current conditions• Monitors pipe temperature (via RTDinputs wired back to the DigiTrace<strong>NGC</strong>-<strong>30</strong>) and alarms upon low orhigh currentcondition<strong>NGC</strong>-UIT2<strong>NGC</strong>-<strong>30</strong>-CRM/CRMS1 7 2 8 3 9 4 10 5 11 6 12C<strong>NGC</strong>-<strong>30</strong>-CTMPanelboardRTDPipeHeatingcableIndividual Controls with RMM2 for Ground-fault Trip/Current/Temperature Monitoring with Networked RTDs• Monitors ground-fault current andalarms/trip control contactor uponfault• Monitors heater current and alarmsupon low or high current conditions• Monitors pipe temperature (via RTDinputs wired back to the DigiTrace<strong>NGC</strong>-<strong>30</strong>) and alarms upon low orhigh current conditions• Using optional RMM2 (remotemonitoring modules) mounted in thefield, up to 128 RTD inputs can beadded to the <strong>NGC</strong>-<strong>30</strong> system.• The RMMs allow the RTD cables tobe terminated locally and only a singleRS-485 twisted wire pair broughtback to the panel. This results in asignificant reduction in field wiring.<strong>NGC</strong>-UIT2<strong>NGC</strong>-<strong>30</strong>-CRM/CRMS1 7 2 8 3 9 4 10 5 11 6 12CRTD<strong>NGC</strong>-<strong>30</strong>-CTMPanelboardIndividual Ambient or PASC Control with Ground-fault Trip/Current/Temperature Monitoring• Monitors ground-fault current andalarms/trip control contactor uponfault• Monitors heater current and alarmsupon low or high current conditions<strong>NGC</strong>-<strong>30</strong>-CRM/CRMSAmbientRTDRS-485PipeHeatingcablePipeHeatingcableRMM2Remotemonitoringmodule<strong>NGC</strong>-UIT21 7 C2 83 9 4 10 5 11 6 12<strong>NGC</strong>-<strong>30</strong>-CTMPanelboard8 / 12EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/13THERMAL MANAGEMENT SOLUTIONS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!