NGC-30 - Pentair Thermal Management

NGC-30 - Pentair Thermal Management NGC-30 - Pentair Thermal Management

thermal.pentair.com
from thermal.pentair.com More from this publisher
12.07.2015 Views

NGC-30Temperature Sensor InputsTemperature inputs per NGC-UIT2TypesHard-wired:Up to 260 hard-wired temperature inputs, one per circuitRMM2 (optional):Up to 128 RTD inputs via RMM2 Modules. Up to 8 RTDs per RMM2 Module andup to 16RMM2 Modules per NGC-30 controllerPLI module (optional; NGC-30 EMR Panel only):Up to 127 RTDs via SES Transmitter (per PLI Module)Up to 127 RTDs via SPC Transmitter (per PLI Module)Up to 255 RTDs via 700-TT Transmitter (per PLI Module)Four PLI Modules per circuit, maximums 1040 RTDs100 Ω platinum RTD, 3-wire, α = 0.00385 ohms/ohm/°CCan be extended with a 3-conductor shielded cable of 20 Ω maximum perconductor(Note: power wire and RTD wire should not be housed in the same conduit).Alarm OutputsRelay Outputs3 SPDT Form C. Rating: 3 A 100 – 277 VacEach relay may be assigned to alarm outputsProgramming and SettingMethodVia NGC-UIT2 (User Interface Terminal)Units °F or °CDigital displayNGC-UIT2-ORD7 inch x 5 ¼ inch LCD color touch screen (17.5 cm X 13.3 cm)NGC-UIT2-HAZ10.4 inch LCD color touch screen with interval LED backlightMemoryNonvolatile, restored after power lossStored parameters (measured)Minimum and maximum temperatures, contactor cycle count, heater time in useAlarm conditionsLow/high temperature, low/high current, ground-fault alarm and trip, RTD failure,communications failure, relay failure, relay count, total time heater energized,contactor failureUser Interface Terminals (UITs)NGC-UIT2-ORDNGC-UIT2-HAZNGC-UIT2-ORD-RArea Classification:Usage:Area Classification:Usage:Nonhazardous (Unclassified) LocationsNEMA 4 (indoors or outdoors)Nonhazardous (Unclassified) or Hazardous LocationsNEMA 4 (indoors or outdoors)Area Classification: Nonhazardous (Unclassified) Locations• The NGC-UIT2-ORD-R must be installed in a nonhazardous,indoor or outdoor location.• The NGC-UIT2-ORD-R connects to DigiTrace NGC-30 panelsusing RS-485 communications wiring.Usage: NEMA 4 (indoors or outdoors)Language SupportEnglish, Spanish, French, German, Russian, Chinese, Italian, CzechConnection TerminalsHeating cable outputGroundRTD / alarm / communicationsScrew terminals, 20–6 AWG (30 A versions), 14–2 AWG (60 A versions)14–4 AWG ground bar28–12 AWG spring clamp terminals4 / 12EN-DigiTraceNGC30-DS-H58670 09/13THERMAL MANAGEMENT SOLUTIONS

NGC-30Self-RegulatingCablesDistribution (for DigiTrace NGC-30-EMR only)Load powerStandard circuit breakersCircuit breaker amperage rating120 / 208 / 240 / 277 / 347 / 480 / 600 VacUS (United States country code in ordering details):Square D type QOB 120 / 208 / 240Square D type NF 277 / 480CA (Canada country code in ordering details):Cutler Hammer (Canada) type BAB 120 / 208 / 240Cutler Hammer (Canada) type GBH 277 / 480 / 347 / 600120 Vac208, 240, 277, 347, 480, 600 Vac20 A, 30 A, 40 A, 50 A20 A, 30 A, 40 A, 50 A, 60 APower-LimitingCablesMineral InsulatedCablesTypical DigiTrace NGC-30 LayoutMultipoint temperature control withground-fault/current/temperaturemonitoring and optional distribution.LoadpowerterminalblockRTDterminalblocksContactorsThe DigiTrace NGC-30 is a multipoint electronic control, monitoring, and powerdistribution system for heat-tracing used in process temperature maintenanceand freeze protection applications. The system contains DigiTrace controllers,multiple individual Electromechanical Relays (EMRs), or Solid-State Relays (SSRs)and an optional assembled circuit breaker panelboard with a main breaker.The DigiTrace NGC-30 provides the following alarming features per control point.• High/low temperature• Ground fault• High/low current fault• RTD failureThe DigiTrace NGC-30 provides ground-fault monitoring and trip protection forevery heat-tracing circuit and fulfills the requirements of national electricalcodes.NGC-UIT2-ORD orNGC-UIT2-HAZDistributionpanelboardMaincircuitbreakerNGC-30-CTMNGC-30-CRNGC-30-CRM/-CRMSSwing out panel (back view)LonglineHeatingRTB TubingBundlesTank Heating Snow and Ice Control andMonitoringHeat-TracePanelsLeft side panelRight side panelBack panelFront panelEMR PanelsNumber of control points Panelboard size EMR panel size with or without panelboard (nominal)5 12 space 42"H X 36"W x 12"D (wall mount)5 18 space 48"H X 36"W x 12"D (wall mount)10 18, 20, 24 space 48"H X 36"W x 16"D (wall mount)10 30 space 72"H X 36"W x 16"D (includes 12" floor stands)15, 20, 25 30 space 72"H X 36"W x 25"D (includes 12" floor stands)15, 20, 25 42 space 84"H X 36"W x 25"D (includes 12" floor stands)25, 30 42 space 84"H X 36"W x 25"D (includes 6" floor stands)35, 40 42 space 90"H X 36"W x 25"D (includes 6" floor stands)EngineeredProductsSteam-TracingSystemsTechnical DataSheetsTHERMAL MANAGEMENT SOLUTIONS EN-DigiTraceNGC30-DS-H58670 09/135 / 12Appendixes

<strong>NGC</strong>-<strong>30</strong>Self-RegulatingCablesDistribution (for DigiTrace <strong>NGC</strong>-<strong>30</strong>-EMR only)Load powerStandard circuit breakersCircuit breaker amperage rating120 / 208 / 240 / 277 / 347 / 480 / 600 VacUS (United States country code in ordering details):Square D type QOB 120 / 208 / 240Square D type NF 277 / 480CA (Canada country code in ordering details):Cutler Hammer (Canada) type BAB 120 / 208 / 240Cutler Hammer (Canada) type GBH 277 / 480 / 347 / 600120 Vac208, 240, 277, 347, 480, 600 Vac20 A, <strong>30</strong> A, 40 A, 50 A20 A, <strong>30</strong> A, 40 A, 50 A, 60 APower-LimitingCablesMineral InsulatedCablesTypical DigiTrace <strong>NGC</strong>-<strong>30</strong> LayoutMultipoint temperature control withground-fault/current/temperaturemonitoring and optional distribution.LoadpowerterminalblockRTDterminalblocksContactorsThe DigiTrace <strong>NGC</strong>-<strong>30</strong> is a multipoint electronic control, monitoring, and powerdistribution system for heat-tracing used in process temperature maintenanceand freeze protection applications. The system contains DigiTrace controllers,multiple individual Electromechanical Relays (EMRs), or Solid-State Relays (SSRs)and an optional assembled circuit breaker panelboard with a main breaker.The DigiTrace <strong>NGC</strong>-<strong>30</strong> provides the following alarming features per control point.• High/low temperature• Ground fault• High/low current fault• RTD failureThe DigiTrace <strong>NGC</strong>-<strong>30</strong> provides ground-fault monitoring and trip protection forevery heat-tracing circuit and fulfills the requirements of national electricalcodes.<strong>NGC</strong>-UIT2-ORD or<strong>NGC</strong>-UIT2-HAZDistributionpanelboardMaincircuitbreaker<strong>NGC</strong>-<strong>30</strong>-CTM<strong>NGC</strong>-<strong>30</strong>-CR<strong>NGC</strong>-<strong>30</strong>-CRM/-CRMSSwing out panel (back view)LonglineHeatingRTB TubingBundlesTank Heating Snow and Ice Control andMonitoringHeat-TracePanelsLeft side panelRight side panelBack panelFront panelEMR PanelsNumber of control points Panelboard size EMR panel size with or without panelboard (nominal)5 12 space 42"H X 36"W x 12"D (wall mount)5 18 space 48"H X 36"W x 12"D (wall mount)10 18, 20, 24 space 48"H X 36"W x 16"D (wall mount)10 <strong>30</strong> space 72"H X 36"W x 16"D (includes 12" floor stands)15, 20, 25 <strong>30</strong> space 72"H X 36"W x 25"D (includes 12" floor stands)15, 20, 25 42 space 84"H X 36"W x 25"D (includes 12" floor stands)25, <strong>30</strong> 42 space 84"H X 36"W x 25"D (includes 6" floor stands)35, 40 42 space 90"H X 36"W x 25"D (includes 6" floor stands)EngineeredProductsSteam-TracingSystemsTechnical DataSheetsTHERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/135 / 12Appendixes

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!