<strong>NGC</strong>-<strong>30</strong>Temperature Sensor InputsTemperature inputs per <strong>NGC</strong>-UIT2TypesHard-wired:Up to 260 hard-wired temperature inputs, one per circuitRMM2 (optional):Up to 128 RTD inputs via RMM2 Modules. Up to 8 RTDs per RMM2 Module andup to 16RMM2 Modules per <strong>NGC</strong>-<strong>30</strong> controllerPLI module (optional; <strong>NGC</strong>-<strong>30</strong> EMR Panel only):Up to 127 RTDs via SES Transmitter (per PLI Module)Up to 127 RTDs via SPC Transmitter (per PLI Module)Up to 255 RTDs via 700-TT Transmitter (per PLI Module)Four PLI Modules per circuit, maximums 1040 RTDs100 Ω platinum RTD, 3-wire, α = 0.00385 ohms/ohm/°CCan be extended with a 3-conductor shielded cable of 20 Ω maximum perconductor(Note: power wire and RTD wire should not be housed in the same conduit).Alarm OutputsRelay Outputs3 SPDT Form C. Rating: 3 A 100 – 277 VacEach relay may be assigned to alarm outputsProgramming and SettingMethodVia <strong>NGC</strong>-UIT2 (User Interface Terminal)Units °F or °CDigital display<strong>NGC</strong>-UIT2-ORD7 inch x 5 ¼ inch LCD color touch screen (17.5 cm X 13.3 cm)<strong>NGC</strong>-UIT2-HAZ10.4 inch LCD color touch screen with interval LED backlightMemoryNonvolatile, restored after power lossStored parameters (measured)Minimum and maximum temperatures, contactor cycle count, heater time in useAlarm conditionsLow/high temperature, low/high current, ground-fault alarm and trip, RTD failure,communications failure, relay failure, relay count, total time heater energized,contactor failureUser Interface Terminals (UITs)<strong>NGC</strong>-UIT2-ORD<strong>NGC</strong>-UIT2-HAZ<strong>NGC</strong>-UIT2-ORD-RArea Classification:Usage:Area Classification:Usage:Nonhazardous (Unclassified) LocationsNEMA 4 (indoors or outdoors)Nonhazardous (Unclassified) or Hazardous LocationsNEMA 4 (indoors or outdoors)Area Classification: Nonhazardous (Unclassified) Locations• The <strong>NGC</strong>-UIT2-ORD-R must be installed in a nonhazardous,indoor or outdoor location.• The <strong>NGC</strong>-UIT2-ORD-R connects to DigiTrace <strong>NGC</strong>-<strong>30</strong> panelsusing RS-485 communications wiring.Usage: NEMA 4 (indoors or outdoors)Language SupportEnglish, Spanish, French, German, Russian, Chinese, Italian, CzechConnection TerminalsHeating cable outputGroundRTD / alarm / communicationsScrew terminals, 20–6 AWG (<strong>30</strong> A versions), 14–2 AWG (60 A versions)14–4 AWG ground bar28–12 AWG spring clamp terminals4 / 12EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/13THERMAL MANAGEMENT SOLUTIONS

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!