<strong>NGC</strong>-<strong>30</strong>Replacement ComponentsDescription Catalog number Part number<strong>NGC</strong>-<strong>30</strong> ModulesCard Rack Module (for EMRs) <strong>NGC</strong>-<strong>30</strong>-CRM 10720-001Card Rack Module (for SSRs) <strong>NGC</strong>-<strong>30</strong>-CRMS 10720-004Current Transformer Module <strong>NGC</strong>-<strong>30</strong>-CTM 10720-002Voltage Monitoring Module <strong>NGC</strong>-<strong>30</strong>-CVM 10720-005<strong>NGC</strong>-<strong>30</strong> AuxiliaryDB9F-DB9F Null Modem Cable 5 ft <strong>NGC</strong>-UIT2-RS232 20577020Remote Monitoring Module RMM2 051778Remote Monitoring Module with NEMA 4X Enclosure RMM2-4X 523420Power Line Carrier Interface: Smart End Seal Transmitter120 V temperature/continuity transmitter with pipe-mount power connection SPC-P-1P000001049enclosure208–277 V temperature/continuity transmitter with pipe-mount powerSPC-P-2P000001050connection enclosure120 V temperature/continuity transmitter with wall-mount power connection SPC-W-1P000001051enclosure208–277 V temperature/continuity transmitter with wall-mount powerSPC-W-2P000001052connection enclosure120 V temperature/continuity transmitter SES-RTD-1 265212-000208–277 V temperature/continuity transmitter SES-RTD-2 677596-000120 V continuity transmitter SES-CONT-1 293536-000208–277 V continuity transmitter SES-CONT-2 398720-000120 V Smart End Seal replacement transmitter board SES-TT-1 815918-000208–277 V Smart End Seal replacement transmitter board SES-TT-2 771274-000Smart End Seal Replacement RTD and stand assembly SES-RTD-Replace 693618-000Power Line Carrier Interface: 700-TT TransmittersTemperature transmitter 700-TT-R 271095-000Transmitter enclosure- non-haz & Div. 2 locations inclusive of RTD-<strong>30</strong>0-10 700-TT-R-D2 427253-000RTD-Used with MONI-700-TT-R-D2 & MONI-700-TT-R-OPK RTD-<strong>30</strong>0-10 129977-000Transmitter enclosure- Div. 1 locations MONI-700-TT-R-D1 367651-000Transmitter enclosure for off-the-pipe non-haz & Div. 2 locations inclusive 700-TT-OPK 885215-000of RTD-<strong>30</strong>0-10Power Line Carrier Interface: Auxiliary EquipmentFront End Filter – 480 V MONI-700-FEF-480 V 922847-000Front End Filter – 600 V MONI-700-FEF-600 V P000000312PLI Module PLI 488323-000RTD lead wire, per 1000 ft reel MONI-RTD-WIRE 962661-000RS-485 comm. wire, per 1000 ft reel MONI-RS485-WIRE 549097-00010 / 12EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/13THERMAL MANAGEMENT SOLUTIONS
<strong>NGC</strong>-<strong>30</strong>Self-RegulatingCablesOrdering Details<strong>NGC</strong>-<strong>30</strong> – Output – No. of Control Points – Enclosure – Voltage – Panelboard – Breaker or SSR or EMR – MCB – Options<strong>NGC</strong>-<strong>30</strong> – XXX – XX – XXX – XXX/XXX – XX – XX/XX (XX) – XXX – XOutputEMR = ElectromechanicalrelaySSR = Solid-staterelayNo. of control points5, 10, 15, 20, 25, <strong>30</strong>, 35, 40Enclosure12 = NEMA 12(indoors; painted steel)4 = NEMA 4/3R(outdoors; painted steel)4X = NEMA 4X/3RX(outdoors; stainless steel)Voltage120 / 208 Vac120 / 240 Vac 1277 / 480 Vac347 / 600 VacPanelboard0 = none requiredPanelboard size# of control 120/208 120/240 277/480 347/600points Vac Vac Vac Vac5 12 12 18 1810 24 20/<strong>30</strong> 18/<strong>30</strong> 18/2415, 20 <strong>30</strong>/42 <strong>30</strong>/42 <strong>30</strong>/42 <strong>30</strong>/4225, <strong>30</strong> <strong>30</strong>/42 <strong>30</strong>/42 <strong>30</strong>/42 <strong>30</strong>/4235, 40 42 42 42 421 Single phase2 Require remote <strong>NGC</strong>-UIT-ORD-123 Special - Describe special requirement in detail.4 Applies to Canada onlyOptionsCountry InstalledUS = U.S. and Americas (except Canada) [default]CA = CanadaE = Environmental purgeH = Electric heaterN = No UIT installed 2 (a remote <strong>NGC</strong>-UIT2-ORD-R can be ordered separately)PL = PLI Module with 3-pole standard breaker (EMR option panel only)U = If EMR, or SSR with panelboard, then <strong>NGC</strong>-UIT2-ORD installed (ordinary area)If SSR without panel, or Z purged, then <strong>NGC</strong>-UIT2-HAZ installed (hazardous area)V = Voltage monitoring (subtracts one control point)X = Spare partsZ = Z purge (EMR only; Class 1, Division 2 Hazardous Area)SP = Special 3Main circuit breaker0 = none required (choose if no panelboard required)Panelboardsize 120/208 Vac 120/240 Vac 277/480 Vac 347/600 Vac12 50, 100 50, 80, 100 – –18 – – <strong>30</strong>, 50 , 70, 125 20, 40, 60, 9020 – 50, 80, 100 – –24 50, 100 – – 20, 40, 60, 90<strong>30</strong> 50, 100, 150, 225 50, 80, 175, 225 50, 70, 125, 175, 225 40, 60, 90, 150, 20042 50, 100, 150, 225 50, 80, 175, 225 50, 70, 125, 175, 225 40, 60, 90, 150, 200Breaker or SSR or EMRBreakerNo. of C.B./No. of poles (ampere rating)No. of Panelboard 120 208 240 277 480 347 600control Vac Vac Vac Vac Vac Vac Vacpoints size (1P) (2P) (2P) (1P) (2P) (1P) (2P)5 12 5 5 55 18 5 4 5 4 5 4 5 5 5 510 18 – – – 10 6 10 610 20 10 – 9 – – – –10 24 10 10 – – – 10 1010 <strong>30</strong> – – 10 – – – –15 <strong>30</strong> 15 14 14 15 13 15 1315 42 – 15 15 – 15 – 1520 <strong>30</strong> 20 9 9 20 8 20 820 42 – 20 20 – 20 – 2025 <strong>30</strong> 25 4 4 25 4 25 425 42 25 16 16 25 15 25 15<strong>30</strong> <strong>30</strong> <strong>30</strong> – – <strong>30</strong> – <strong>30</strong> –<strong>30</strong> 42 – 10 10 – 10 – 1035 42 35 6 6 35 5 35 540 42 40 – – 40 – 40 –Note: The quantity of breakers must be equal to the number of control points.SSR without panelboardSelect no. of output devices (SSRs)/ no. of poles/amperageOutput devices: 5 – 40Poles:1P or 2PAmperage: <strong>30</strong>, 60EMR without panelboardSelect no. of output devices (EMRs)/ amperageOutput devices: 5 – 40Amperage: <strong>30</strong>, 60Power-LimitingCablesMineral InsulatedCablesLonglineHeatingRTB TubingBundlesTank Heating Snow and Ice Control andMonitoringHeat-TracePanelsEngineeredProductsSteam-TracingSystemsTechnical DataSheetsTHERMAL MANAGEMENT SOLUTIONS EN-DigiTrace<strong>NGC</strong><strong>30</strong>-DS-H58670 09/1311 / 12Appendixes