750 Watt C, X and Ku-BandAntenna Mount AmplifiersWith Block UpconverterFEATURES• Rugged 75 lb. antennamount package• Extended frequency bandavailable• Complete RS-232/422/485 M&C interface• L-band inputThe <strong>XTD</strong>-750-B1 is a series compact, self-contained, antenna mountablepower amplifiers designed for low cost installation and long life. The <strong>XTD</strong>-750-B1 design eliminates the need for an amplifier shelter as well as a longwaveguide run between the amplifier and antenna feed horn. RF filters, cooling,and monitoring & control (M&C) systems are all self-contained within the HighPower Amplifier (HPA). These features provide high reliability, low maintenancecosts, and low replacement costs.The <strong>XTD</strong>-750-B1 uses high efficiency, dual-stage collector Traveling WaveTubes (TWT). Some benefits of this type of tube are: reduced prime power consumption.,lower internal operating temperatures., and reliability enhancement.These benefits are obtained for both the linear and saturated modes of operation.The <strong>XTD</strong>-750-B1 incorporates power factor correction circuitry, whichminimizes line current distortion and reduces the required Volt-Amps. The combinationof power factor correction and high efficiency TWTs reduces inputVolt-Amps by 45% when compared to equivalent amplifiers. A high frequencyresonant conversion power supply is used that accepts a wide range of primepower (180 to 260 VAC). The automatic features of the power supply includequick recovery from prime power outages and multiple helix arc fault resets(three fault cycles). A complete serial M&C system is built into the unit.The <strong>XTD</strong>-750-B1 may be configured for single thread, redundant, phasecombined,or linearized operation. A remote external controller is available tooperate the HPA from a user selected location. Mounting brackets can be suppliedto mount the HPA to most popular antennas.TECHNOLOGY3550 Bassett Street • Santa Clara • CA 95054 • Tel: (408) 213-3000 • Fax: (408) 213-3001www.xicomtech.com • email sales@xicomtech.com


PERFORMANCE SPECIFICATIONParametersFREQUENCY RANGE(extended frequency coverage available)<strong>XTD</strong>-750C-B1C-Band<strong>XTD</strong>-750X-B1X-Band<strong>XTD</strong>-<strong>750K</strong>-B1Ku-BandOutput 5.850 to 6.425 GHz 7.9 to 8.4 GHz 13.75 to 14.5 GHzInput 950 to 1525 MHz 950 to 1400 MHz 950 to 1700 MHzLO Frequency 4900 MHz 6950 MHz 12800 MHzInput Level, w/o damage (maximum)Reference Signal Frequency10 dBmexternal 10 MHz10 MHz Power Level 2 dBm ± 5 dBReferenced Input ImpedanceOUTPUT POWERGAINTraveling Wave TubeRated Power @ Amplifier Flange (minimum)Large Signal (minimum)Small Signal (minimum)Attenuator Range (continuous)Maximum SSG Variation Over50 Ohms750 Watts650 WattsAny Narrow Band 1.0 dB per 40 MHz 1.0 dB per 80 MHz 1.0 dB per 80 MHzFull BandSlope (maximum)Stability, 24 hr. (maximum)Stability, Temperature (maximum)INTERMODULATION (maximum)with two equal carriersHARMONIC OUTPUT (maximum)AM/PM CONVERSION (maximum)NOISE POWER (maximum)Transmit BandReceive BandGROUP DELAY (maximum)-150 dBw/4 kHz3.7 to 4.2 GHz67 dB72 dB25 dB± 2 dB± 0.04 dB/MHz± 0.25 dB± 1.0 dB over temperature range at any frequency-18 dBc@ 4 dB total output power backoff from rated power-60 dBc2.5 deg/dB at 6 dB below rated output power70 dBW/4 kHz-150 dBw/4 kHz10.95 to 12.75 GHz-150 dBW/4 kHz10.95 to 12.75 GHzBandwidth Any 40 MHz Any 80 MHz Any 80 MHzLinear0.01 nS/MHzParabolic 0.005 nS/MHz 2RippleRESIDUAL AM NOISE (maximum)PHASE NOISE (maximumVSWR0.5 nS/Pk-Pk-60 dB > 100 kHz from carrierAC fundamental -50 dBcSum of all spurs -47 dBcPer IESS phase noise profileAC fundamental -50 dBcSum of all spurs -47 dBcInput (maximum) 1.8:1Output (maximum) 1.3:1TECHNOLOGY<strong>XTD</strong>-750-B1


BLOCK DIAGRAMOUTLINE DRAWING<strong>XTD</strong>-750-B1TECHNOLOGY


PRIME POWER180 to 260 VAC47 to 63 Hz, Single Phase2450 VA (maximum)0.95 Minimum Prime Power FactorENVIRONMENTNONOPERATING TEMPERATURE RANGEOPERATING TEMPERATURE RANGEHUMIDITYALTITUDESHOCK AND VIBRATIONCOOLINGINTERFACETypeOPTIONS-50°C to +70°C-40°C to +60°C(2°C/1000 Feet Derating)Up to 100% Condensing10,000 Feet MSL (maximum)Normal TransportationForced AirFunctionLOCAL CONTROL Prime Power ON/OFF Local/RemoteLOCAL STATUSPower Supply ON/OFFTri-Color LED:Fault: RedHV ON: GreenHV ON/OFFStandby: Continuous AmberFTD: Flashing AmberREMOTE CONTROL HV ON/OFF Constant PowerMin/Max Power Alarm/FaultRF Attenuation (w/preamp)Heater Standby ON/OFFRF Inibit (HV OFF)Fault ResetREMOTE STATUS RF Output Power Reflected PowerFORM C DRY CONTACTCLOSURERF MONITOR PORTHelix CurrentHeater/Beam HoursAttenuator SettingTWT TemperatureSummary Fault-43 dB Coupling Value (approx.)• Remote External Controller• 1:1, 1:2, 1:N Redundancy• Integrated Linearizer• Input Diplexer (combining IF & 10 MHz reference)• Reverse RF Inhibit• Extended Frequency CoverageHelix VoltageFilament Time DelayHV ONFault IdentificationHeadquarters<strong>Comtech</strong> <strong>Xicom</strong> <strong>Technology</strong>, Inc.3550 Bassett StreetSanta Clara, CA 95054USAPhone: +1-408-213-3000Fax: +1-408-213-3001email: sales@xicomtech.comWeb: www.xicomtech.com. . . . . . . . . .Europe Sales Office<strong>Comtech</strong> <strong>Xicom</strong> <strong>Technology</strong> Europe, LTD4 Portland Business CenterManor House LaneDatchetBerkshire SL3 9EGUnited KingdomPhone: +011 44 (0) 1753 549 999Fax: +011 44 (0) 1753 549 997email: sales@xicomeurope.comWeb: www.xicomtech.com. . . . . . . . . .Asia Sales Office<strong>Comtech</strong> <strong>Xicom</strong> <strong>Technology</strong>150 Cecil Street#08-02Singapore 069543Phone: +011 65 6325 1953Fax: +011 65 6325 1950email: asiasales@xicomtech.comWeb: www.xicomtech.comTECHNOLOGYDocument <strong>XTD</strong>-750-B1 Rev 8, 05/16/2012© 2012Note: Technical specifications are subject to change without notice. Pleasecontact <strong>Xicom</strong> <strong>Technology</strong> before using this information for system design.