Configuring CoreSight systems6.2 Reading <strong>the</strong> CoreSight ROM tableIf <strong>the</strong> target system contains a valid CoreSight ROM table, you can use this to configure <strong>the</strong>AHB-AP and APB-AP devices behind <strong>the</strong> <strong>Debug</strong> Access Port (DAP).To configure CoreSight devices using a CoreSight ROM table:• If you are manually adding devices to <strong>the</strong> scan chain:1. Add <strong>the</strong> <strong>ARM</strong>CS-DP device.2. Right-click on <strong>the</strong> <strong>ARM</strong>CS-DP device, <strong>the</strong>n select <strong>the</strong> Read CoreSight ROMTable option.• If you are autoconfiguring scan chain, ensure that <strong>the</strong> Read CoreSight ROM Tablescheckbox is selected before you auto configure. The checkbox is selected by default.6.2.1 See alsoTasks• Setting up a CoreSight trace association file on page 6-11• Loading a trace association file on page 6-13Concepts• About CoreSight system configuration on page 6-2• CoreSight autodetection on page 6-4• How <strong>the</strong> debug hardware unit autodetects Serial Wire <strong>Debug</strong> on page 6-5.<strong>ARM</strong> DUI 0498F Copyright © 2010-2012 <strong>ARM</strong>. All rights reserved. 6-3ID021112Non-Confidential