Creating debug hardware target configurations5.6 Autoconfiguring a scan chainTo autoconfigure a scan chain:1. Select <strong>the</strong> Devices node in <strong>the</strong> tree diagram.If a scan chain configuration is already set up and has a platform assigned to it,autoconfiguration is disabled in <strong>Debug</strong> <strong>Hardware</strong> Config. If you want to reconfigure <strong>the</strong>scan chain automatically, click Clear Platform before continuing.NoteBefore you autoconfigure a target that supports both JTAG and SWD, you must firstenable Use SWJ Switching in <strong>the</strong> Advanced configuration settings.2. Click on Auto Configure. Each detected device is added to <strong>the</strong> scan chain configurationlist in <strong>the</strong> control pane, and is also added to <strong>the</strong> tree diagram. In many cases, this is all thatyou have to do to configure <strong>the</strong> scan chain. You must <strong>the</strong>n configure <strong>the</strong> devices<strong>the</strong>mselves.3. If a scan chain configuration is already set up, <strong>the</strong> following Auto Configure Scan Chainprompt might be displayed:Figure 5-5 Auto Configure Scan Chain dialog boxCautionIf you click OK, your current scan chain configuration is lost.5.6.1 See alsoTasks• Adding devices to <strong>the</strong> scan chain on page 5-12• Removing devices from <strong>the</strong> scan chain on page 5-16• Changing <strong>the</strong> order of devices on <strong>the</strong> scan chain on page 5-17• Setting <strong>the</strong> clock speed on page 5-24• Troubleshooting autoconfigation of a scan chain on page 10-11.Setting up <strong>the</strong> <strong>ARM</strong> <strong>DS</strong>TREAM <strong>Hardware</strong>:• Connecting <strong>the</strong> <strong>DS</strong>TREAM unit on page 3-3.Setting up <strong>the</strong> <strong>ARM</strong> RVI and RVT <strong>Hardware</strong>:• Connecting <strong>the</strong> RVI hardware on page 3-5.Reference• Device Properties dialog box on page 5-21• <strong>Debug</strong> hardware device configuration settings on page 5-26• <strong>Debug</strong> hardware Advanced configuration settings on page 5-33.<strong>ARM</strong> DUI 0498F Copyright © 2010-2012 <strong>ARM</strong>. All rights reserved. 5-11ID021112Non-Confidential

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!