4/36 Bosch Rexroth Corp. <strong>A<strong>A2FM</strong></strong> RA 91 001/07.05Technical DataHydraulic fluidSelection diagramBefore starting project planning, please refer to our datasheets RE 90220 (mineral oil), RE 90221 (environmentallyacceptable hydraulic fluids) and RE 90223 (HF hydraulicfluids) for detailed information regarding the choice of hydraulicfluids and conditions of use.The <strong>A<strong>A2FM</strong></strong> fixed displacement motor is not suitable for usewith HFA. If HFB, HFC and HFD or environmentally acceptablehydraulic fluids are being used, the limitations regardingtechnical data and seals mentioned in RE 90221 andRE 90223 must be observed. When ordering please indicatehydraulic fluid used.viscosity ν SUS (mm2/s)7000500030002000100050030020015010080706050(1600)(1000)(600)(400)(200)(100)(60)(40)(20)(10)(-40°) (-20°)(0°) (20°) (40°) (60°) (80°) (100°)VG 22VG 32VG 68VG 46VG 1007400(1600)170 (36)νopt.80 (16)Viscosity rangeWe recommend that a viscosity (at operating temperature) foroptimum efficiency and service life purposes ofν opt = optimum viscosity 80...170 SUS (16...36 mm 2 /s)selected, taken into consideration the circulation temperature(closed circuit) and tank temperature (open circuits).Limits of viscosity rangeThe following values apply in extreme cases:Sizes 5...200:ν min = 42 SUS (5 mm 2 /s)short term (t < 3 min) at max. permitted temperature oft max = +240°F (+115°C).ν max = 7400 SUS (1600 mm 2 /s),short term (t < 3 min) with cold start (p ≤ 435 psi / 30 bar,n ≤ 1000 rpm, t min = -40°F / -40°C).Sizes 250...1000:ν min = 60 SUS (10 mm 2 /s),short term (t < 3 min) at max. permitted temperature oft max = +195°F (+90°C)ν max = 4600 SUS (1000 mm2/s),short term (t < 3 min) with cold start (p ≤ 435 psi / 30 bar,n ≤ 1000 rpm, t min = -13°F / -25°C).Note that the maximum hydraulic fluid temperature must not beexceeded locally either (e.g. bearing area). The temperature inthe bearing area is - depending on pressure and speed - up to22 °F (12 K) higher than the average case drain temperature.Special measures are necessary at temperatures between-40°F and -13°F (-40°C and -25°C). Please contact us.See RE 90300-03-B for detailed information about operationat low temperatures.40(5)42 (5)(-40°) (-25°) (-10°) (0°) (10°) (30°) (50°) (70°) (90°) (115°)-40° -13° 0° 20° 40° 60° 80° 120° 160° 195° 240°t min = -40°F(-40°C)fluid temperature range t in °F (°C)t max = +240°F(+115°C)Details regarding the choice of hydraulic fluidTo select the correct hydraulic fluid in open circuit applications,the temperature in the tank in relation to the ambient temperaturemust be considered.The hydraulic fluid should be selected so that within theoperating temperature range, the operating viscosity lies withinthe optimum range (ν opt ) (see shaded section of the selectiondiagram). We recommend that the highest possible viscosityrange should be selected in each case.Example: At an ambient temperature of X°F (X°C) an operatingtemperature of 140°F (60°C) is set in the circuit. In theoptimum operating viscosity range (ν opt ; shaded area) thiscorresponds to the viscosity classes VG 46 or VG 68; to beselected: VG 68.Please note: The leakage fluid temperature, which is affectedby pressure and rotational speed, is always higher than the circuittemperature or tank temperature. At no point in the systemmay the temperature be higher than 240°F (115°C) for sizes 5to 200 or 195°F (90°C) for sizes 250 to 1000.If this cannot be achieved due to unusual operating parametersor high ambient temperatures, we recommend to apply bearingflushing at port U (sizes 250 ... 1000) or the use of a flushingand boost pressure valve (see page 30).FiltrationThe finer the filtration, the cleaner the fluid, the longer the servicelife of the axial piston unit.To ensure proper function of the axial piston unit, the Hydraulicfluid must have a cleanliness level of at least20/18/15 according to ISO 4406.At very high hydraulic fluid temperatures (90°C to max. 115°C, notpermitted for sizes 250 to 1000), a cleanliness level of at least19/17/14 according to ISO 4406 is required.Please contact us if these cleanliness leveles cannot be achieved.
RA 91 001/07.05 <strong>A<strong>A2FM</strong></strong> Bosch Rexroth Corp. 5/36Technical DataOperational pressure rangeMaximum pressure on port A or B (pressure data according to DIN 24312)AA2F Sizes 10 12 16 23 28 32 45 56 63 80 90 107 125 160 180 250 Nominal pressure Peak pressureShaft end: S5800 psi (400 bar) 6500 psi (450 bar)S5100 psi (350 bar) 5800 psi (400 bar)Q4350 psi (300 bar) 5100 psi (350 bar)Q4000 psi (280 bar) 4600 psi (315 bar)T5800 psi (400 bar) 6500 psi (450 bar)U5800 psi (400 bar) 6500 psi (450 bar)B5100 psi (350 bar) 5800 psi (400 bar)P5100 psi (350 bar) 5800 psi (400 bar)K5100 psi (350 bar) 5800 psi (400 bar)A2F Sizes 5 200 355 500 710 1000 Nominal pressure Peak pressureShaft end: Z5100 psi (350 bar) 5800 psi (400 bar)A5800 psi (400 bar) 6500 psi (450 bar)P5100 psi (350 bar) 5800 psi (400 bar)B5100 psi (350 bar) 5800 psi (400 bar)B3000 psi (210 bar) 3600 psi (250 bar)C4600 psi (315 bar) 5100 psi (350 bar)With pulsating loads over p N = 4600 psi / 315 bar (p max = 5100 psi / 350 bar);we recommend the use of a splined shaft (<strong>A<strong>A2FM</strong></strong> 10...250: S, T or U / <strong>A2FM</strong> 200: A / <strong>A2FM</strong> 355...1000: Z)The sum of the pressure at ports A and B may not exceed 10000 psi / 700 bar (A2F5: 9000 psi / 630 bar)Attention: shaft end with drives of radial force loads at the drive shaft (pinion, V-belt drives) necessitate reduction of the nominalpressure to p N = 4600 psi (315 bar)! Sizes 250...1000 please contact us.Minimum inlet pressure, see page 8Direction of flowDirection of rotation, viewed on shaft endclockwisecounter-clockwiseA to BB to ASpeed rangeNo limit to minimum speed n min . If uniform motion is required,nmin must not be less than 50 rpm. See table on page 7 formaximum speed.Long-life bearing (sizes 250...1000)For long service life and use with HF hydraulic fluids. Same externaldimensions as the motor with standard long-life bearingcan be supplied. Flushing of bearing and case via the U-port isrecommended.Flow (recommended)Size 250 355 500 710 1000q v flow gpm 2.6 4.2 4.2 4.2 4.2L/min 10 16 16 16 16