12.07.2015 Views

Actassi catalogue - Schneider Electric

Actassi catalogue - Schneider Electric

Actassi catalogue - Schneider Electric

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Actassi</strong> EnclosuresVDS19" serverRobust and ventilatedIntroductionTechnical characteristics■■Folded and welded sheet-steel enclosure, textured, RAL 9011 blackepoxy-polyester powder paint.■■Earth continuity guaranteed, according to the standard.■■Allowed air flow above 80%■■Acceptable static load: 750 kg.■■Color:– Black (RAL9011)■■Ingress Protection : IP20– Object size protected against > 12,5mm– No liquid protected■■Impact Potection : IK10– Impact energy = 20 joules■■Certifications: In compliance with the directive RoHs, with the 19" standardIEC60297-3-100 and EIA-310DRack composition■ ■ Top and bottom frames, mechanically assembled by Torx screws to the verticalstructure uprights, thus forming a rigid framework.■■Base without blanking plate (page XX).■■Cut-out roof, closed with a blanking plate with dismountable brush gasket.■■Reversible microperforated front and rear door, opening to 180°, closure at 2 pointswith a handle and a key nº 333. Hinges on the right as standard.■■Side panels with no louvres, with quick installation and removal, closing by latches.■■Top and bottom side cable entries flush with the structure.■■Top and bottom side knock-out areas for cable entry, with a width of 800 mm.■■Large opening on the bottom and large knock-out area on the rear for cable entry.■■Levelling feet installed.■■Four 19" uprights made from treated steel, installed 100 mm back from the frontplate and depth-adjustable in steps of 25 mm.■■Earthing kit installed.■■Delivered on a pallet covered with film.Composition of the rack without side panels■■Exactly the same composition as the above rack, but without the side panels.■■Coupling kit not supplied.■ ■ In the event of coupling, use coupling kit ref. NSYCUNVDA and brush gasket (ref.NSYCUNPL600, NSYCUNPL800 or NSYCUNPL1000) to close the cable entry leftby the 2 side panels.Selection guideNumber of UExt. dimensions (mm)Height Width DepthRack24U 1200 600 1000 NSYVDS24U610N42U 2000 600 1000 NSYVDS42U610N42U 2000 800 800 NSYVDS42U88N42U 2000 800 1000 NSYVDS42U810NNetwork Connectivity Jan 2013<strong>Actassi</strong> | 105

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!