ACE Excel Ultra Robust UHPLC Columns - Winlab.com.au

ACE Excel Ultra Robust UHPLC Columns - Winlab.com.au

ACE Excel Ultra Robust UHPLC Columns - Winlab.com.au

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

<strong>Excel</strong>TM<strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>• High efficiency 2µm particles• Unique phases for rapid method development• Compatible with <strong>UHPLC</strong> and HPLC systems• HSC TM High Stability <strong>Columns</strong> – ultra robust columns up to 1,000 bar (15,000psi)<strong>UHPLC</strong> <strong>Columns</strong><strong>Excel</strong>TM


<strong>ACE</strong> ® <strong>Excel</strong> TM<strong>UHPLC</strong> <strong>Columns</strong>Designed to take full advantage of low dispersion, ultra-highpressure UPLC ® and <strong>UHPLC</strong> instruments, the introduction of<strong>ACE</strong> ® <strong>Excel</strong> TM<strong>UHPLC</strong> columns gives chromatographers morechoices to achieve better results.<strong>Ultra</strong> robust columns – Unique phases – High efficiency 2µm particlesNEW High Efficiency 2µm <strong>ACE</strong> Particles<strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns are available in a new high efficiency 2µm particle size. Selectivity is unchanged fromexisting 3µm, 5µm and 10µm <strong>ACE</strong> HPLC phases. <strong>Excel</strong>lent peak shape, great column-to-column reproducibilityand exceptional column ruggedness is now available to UPLC and <strong>UHPLC</strong> users with <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns.HSC TM High Stability <strong>Columns</strong>All <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns are manufactured using a proprietary HSC (High Stability Column) manufacturingprocess that results in ultra robust <strong>UHPLC</strong> columns.Optimised <strong>UHPLC</strong> Hardware<strong>ACE</strong> <strong>Excel</strong> columns utilise specially developed low dispersion hardware which enables high efficiency <strong>UHPLC</strong>separations up to a maximum pressure limit of 1,000 bar (15,000psi).Unique Stationary Phases<strong>ACE</strong> <strong>Excel</strong> 2µm columns are available with C18-PFP and C18-AR “ExtraResolving Power” phases. These two unique phases offer multiple mechanisms ofseparation and have been specifically developed to provide alternative selectivityto C18 phases. <strong>ACE</strong> <strong>Excel</strong> 2µm columns are also available with C18, C8, C4, CN,AQ, Phenyl and Silica phases.<strong>ACE</strong> ® StationaryPhases VirtuallyEliminate theNegative Effectsof Silanols on <strong>UHPLC</strong>and HPLC SeparationsSi-OHBetter <strong>UHPLC</strong> ResultsThe introduction of <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns means chromatographers now have more choices within theirreach to achieve better results with their UPLC and <strong>UHPLC</strong> instruments.Performance Boost for HPLC Instrumentation<strong>ACE</strong> <strong>Excel</strong> 2µm <strong>UHPLC</strong> columns provide significantly lower back pressure than other UPLC and <strong>UHPLC</strong> columnspacked with


<strong>ACE</strong> ® <strong>Excel</strong> TM <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>High speed, high resolution, <strong>UHPLC</strong> separations<strong>ACE</strong> ® <strong>Excel</strong> TM 2µm <strong>UHPLC</strong> columns• Fully <strong>com</strong>patible with all <strong>com</strong>mercial UPLC and <strong>UHPLC</strong> instruments• Brings renowned <strong>ACE</strong> HPLC columns’ advantages to <strong>UHPLC</strong> columns• Delivers a high level of reliability and ruggedness• Offers easy scalability from <strong>UHPLC</strong> to HPLC to preparative HPLC• Provides users of UPLC/<strong>UHPLC</strong> with additional choices in stationary phases, includingthe powerful C18-AR and C18-PFP phasesFigure 1: <strong>ACE</strong> ® <strong>Excel</strong> TMunique stationary phase columns provide alternative selectivity with high speed, highresolution separationsApplication #1500 – HPLC to <strong>UHPLC</strong> OptimisationSample: 1) 1,2-dimethoxybenzene 2) 1,3-dimethoxybenzene 3) 1,3,5-trimethoxybenzene 4) tolueneMobile Phase: MeOH/H 2O (50:50 v/v) Temperature: 40°C Detection: UV, 210 nm3HPLC(~13 minutes)R s= 1.71 2Waters XBridge 5 C18150 x 4.6 mm, 1.00 ml/mint r4= 13.60 mins43UPLC(~4.5 minutes)R s= 1.1t r4= 4.69 mins4Waters ACQUITY 1.7 BEH C1850 x 2.1 mm, 0.21 ml/min1 234<strong>UHPLC</strong>(


<strong>ACE</strong> ® <strong>Excel</strong> TM <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>All the well known advantages of <strong>ACE</strong> ® HPLCcolumns are now available for <strong>UHPLC</strong><strong>ACE</strong> ® <strong>Excel</strong> TM Advantages• <strong>Excel</strong>lent peak shape for basic andacidic <strong>com</strong>pounds• Exceptional column-to-columnreproducibility• Rugged and reliable day-to-dayperformance and superb columnlifetimeFigure 2: <strong>ACE</strong> ® <strong>Excel</strong> TM delivers excellent resolution and peak shapeApplication #1501 – Pharmaceuticals and Related Compounds by <strong>UHPLC</strong>Mobile Phase: A = 5 mM formic acid in H 2Oand B = 5 mM formic acid in MeOHGradient: 3 to 100% B in 5 minutesFlow Rate: 0.6 ml/minTemperature: 40°CDetection: UV, 254 nmColumn Dimensions: 50 x 2.1mm1. paracetamol2. hydrochlorothiazide3. methylphenylsulphoxide4. methylphenylsulphone5. aspirin6. phenacetin7. 1,3-dinitrobenzene8. 1,2,4-trimethoxybenzene9. ethylbenzoate10. nimesulide11. ibuprofen12. indomethacin13. mefenamic acidLeverage the power of bonded phaseselectivity and <strong>com</strong>bine it with <strong>UHPLC</strong>efficiency and speed<strong>ACE</strong> <strong>Excel</strong> 2 C182 13, 45768109P max= 374 bar121311C18 bonded phases are the mostpopular phases for HPLC/<strong>UHPLC</strong>bec<strong>au</strong>se they offer good retention andselectivity for a wide variety of sampletypes. In addition, they are perceived tobe more rugged and reliable than otherbonded phases. C18 bonded phasesdepend mainly on hydrophobicinteractions (and occasionally shapeselectivity) to achieve satisfactoryseparations. Although versatile, C18phases offer a limited number ofseparation mechanisms and this maylead to less than optimum separationsin some cases and <strong>com</strong>plete lack ofresolution of important peak pairsin others.Zorbax Eclipse1.8 XDB C18Waters ACQUITY1.7 BEH C18PhenomenexKinetex 1.7 C182 13, 42 1341, 234 575576676888101091099P max= 540 bar121311P max= 581 bar121311P max= 540 bar121311<strong>ACE</strong> columns have led the way inoffering C18 bonded phases with theadvantage of ‘extra selectivity’.C18-AR and C18-PFP bonded phaseshave proved to be extremelypowerful tools to use in leveraging this‘extra selectivity’ to achieve separationsthat may not be possible with‘standard’ C18 bonded phases. These‘extra selectivity’ phases are not meantto replace ‘standard’ C18 bonded phases,but rather <strong>com</strong>plement them and soprovide chromatographers withpowerful, additional mechanisms ofseparation that can be used to achievebetter overall chromatographic results.The introduction of <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong>columns means that chromatographersnow have more choices within theirreach to achieve better results withtheir UPLC and <strong>UHPLC</strong> instruments.<strong>ACE</strong> <strong>Excel</strong> 2 C18-AR<strong>ACE</strong> <strong>Excel</strong> 2 C18-PFP121 234 50 1 2 3 45MinutesComparative data may not be representative of all applications.Please see p.10 for acknowledgement of trademarks.34 5The above example highlights that these leading C18 brands providesimilar selectivity and fail to fully resolve the <strong>com</strong>ponents under theseconditions, with 2 or more critical pairs non baseline resolved in each case.The unique selectivity of the <strong>ACE</strong> <strong>Excel</strong> C18-AR and the <strong>ACE</strong> <strong>Excel</strong> C18-PFPphases enable improved separations.6687789P max= 364 bar12101311P max= 365 bar1210139 112<strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>www.ace-hplc.<strong>com</strong>


<strong>ACE</strong> ® <strong>Excel</strong> TM <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>Fully <strong>com</strong>patible with all <strong>com</strong>mercial UPLC and<strong>UHPLC</strong> instrumentsCompatible with all UPLC and <strong>UHPLC</strong> Systems<strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns are designed to be fully<strong>com</strong>patible with all <strong>com</strong>mercial UPLC and <strong>UHPLC</strong>instruments and have been engineered to benefitfrom the high flow rate, ultra-high pressure and lowdispersion of these systems. <strong>ACE</strong> <strong>Excel</strong> columns providechromatographers with more column choices sothat even more value can be obtained from theirUPLC/<strong>UHPLC</strong> instruments.Performance Boost for HPLC SystemsOwing to the optimal 2µm particle size and a rigorousclassification protocol, column back pressure issignificantly lower than for traditional UPLC and <strong>UHPLC</strong>columns packed with


<strong>ACE</strong> ® <strong>Excel</strong> TM <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>Column-to-column reproducibility and ultrarobust, reliable performance<strong>Excel</strong>lent ReproducibilityColumn-to-column reproducibilityis affected by a number of factorsincluding the production of the silicastationary phase support, themanufacture of the silane stationaryphase, the bonding of the stationaryphase to the support and thepacking of the stationary phase intothe column. The more tightly eachstage of the column manufacturingprocess is controlled, the better thequality of the resultant column will be.<strong>ACE</strong> columns are subjected to extensivecontrols at each stage of themanufacturing process, to ensurethat <strong>ACE</strong> columns produce reliable,predictable high performanceseparations from column-to-columnand batch-to-batch.Figure 4: <strong>ACE</strong> ® <strong>Excel</strong> TM <strong>UHPLC</strong> columns are exceptionally durableApplication #1506% Initial Efficiency120100806040200Prototype 2µm C18 Column(column manufactured withoutHSC packing technology)Number of Injections<strong>ACE</strong> <strong>Excel</strong> 2 C18 <strong>UHPLC</strong> Column(column manufactured with HSCpacking technology)0 500 1000 1500 2000Fast Gradient Conditions:Column Dimensions: 100 x 2.1 mm Flow Rate: 0.73 ml/min P max= 1,000 bar (15,000psi)Mobile Phase: A = 0.1% formic acid in H 2O B = 0.1% formic acid in MeOHGradient: 20% to 90%B in 6 minutes, 1 minute hold90% to 20%B in 1 minute, 2 minutes re-equilibration holdHSC TM High Stability <strong>Columns</strong>All <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns aremanufactured using a proprietaryHSC (High Stability Column) packingtechnology, which results in ultra robustcolumns.<strong>ACE</strong> <strong>Excel</strong> 2 C18 – StartNot only are <strong>ACE</strong> <strong>Excel</strong> columns packedexceptionally well, they incorporate aninlet frit design that reduces the risk ofplugging.0 1 2 3 4 5 6 7MinutesIt is still re<strong>com</strong>mended that you filtersamples and mobile phases as youwould with any <strong>UHPLC</strong> column, but<strong>ACE</strong> <strong>Excel</strong> columns provide the samelevels of durability and lifetime that youwould expect from HPLC columns.<strong>ACE</strong> <strong>Excel</strong> 2 C18 – After 2,000 fast gradient cycles0 1 2 3 4 5 6 7MinutesEfficiency and peakshape unchangedFigure 4 illustrates the excellent columnlifetime provided by an <strong>ACE</strong> <strong>Excel</strong>column under searching fast gradient<strong>UHPLC</strong> conditions.A 100 x 2.1mm <strong>ACE</strong> <strong>Excel</strong> 2µm C18 <strong>UHPLC</strong> column manufacturedusing the proprietary HSC (High Stability Column) packingtechnology was subjected to a gradient cycle incorporating a P maxof1,000 bar (15,000psi). After over 2000 cycles, the column efficiency,peak shape and retention times were essentially unchanged.In contrast a Prototype 2µm C18 column manufactured from thesame silica but without the proprietary HSC column packingtechnology was seen to rapidly deteriorate.4<strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>www.ace-hplc.<strong>com</strong>


<strong>ACE</strong> ® <strong>Excel</strong> TM <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>Easy scalability from <strong>UHPLC</strong> to HPLC toPreparative HPLCFigure 5: Selectivity is preserved and assured when scaling <strong>ACE</strong> ®stationary phases from <strong>UHPLC</strong> (2µm) to HPLC (3µm and 5µm) topreparative HPLC (10µm)Application #1502 – Reproducible Scale-upMobile Phase: 35:65 MeCN/0.1%TFA in H 20Temperature: 22°CWavelength: 254 nm<strong>ACE</strong> <strong>Excel</strong> 2 C18150 x 2.1mm(0.21ml/min)1231) uracil2) 4-hydroxybenzoic acid3) acetylsalicylic acid4564) benzoic acid5) 2-hydroxybenzoic acid6) ethyl paraben<strong>UHPLC</strong>All <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns areavailable in larger particle sizeequivalents and larger non-analyticaldimensions.For <strong>ACE</strong> stationary phases, thesame controls that ensure highlyreproducible columns from batch-tobatchalso ensure that you can transfermethods more easily from <strong>UHPLC</strong>to HPLC, or vice-versa, or scale-upto preparative applications whenneeded to isolate or purify a target<strong>com</strong>pound. The column efficiencywill, of course, change, but theselectivity will be predictably the same.<strong>ACE</strong> 3 C18150 x 3.0mm(0.40ml/min)123456ScalableFullyHPLC<strong>ACE</strong> 5 C18150 x 4.6mm(1.00ml/min)123456ScalableFully<strong>ACE</strong> 10 C18150 x 21.2mm(21.2ml/min)1 230 1 2 3 4 5 6 7Minutes456PrepHPLCThese chromatograms of a test sample run under the same mobilephase conditions on an <strong>ACE</strong> <strong>Excel</strong> 2µm C18 <strong>UHPLC</strong> column, an <strong>ACE</strong>3µm C18 HPLC column, an <strong>ACE</strong> 5µm C18 HPLC column and an <strong>ACE</strong>10µm C18 preparative HPLC column illustrate the consistentselectivity inherent in all <strong>ACE</strong> stationary phases, regardless of particlesize. This permits easier transfer of methods from <strong>UHPLC</strong> to HPLCor HPLC to <strong>UHPLC</strong>. It also makes it easier to scale-up from analyticalto preparative applications.<strong>UHPLC</strong> <strong>Columns</strong><strong>Excel</strong>TMwww.ace-hplc.<strong>com</strong><strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>5


C18Figure 6: Comparison of selectivity and characteristics of<strong>ACE</strong> ® <strong>Excel</strong> TM 2µm C18 to other manufacturers’ columnsApplication #1503 – Rapid <strong>UHPLC</strong> Screening of 16 Pharmaceuticals and Related CompoundsMechanisms ofSeparationStrength ofInteractionMobile Phase: A = 20 mM KH 2PO 4, pH 2.7 andB = 20 mM KH 2PO 4, pH 2.7 in MeOH/H 2O (65:35 v/v)Gradient: 3 to 100% B in 5 minutesFlow Rate: 0.6 ml/minTemperature: 60°CDetection: UV, 214 nmColumn Dimensions: 50 x 2.1mm31. N-acetylprocainamide2. 3-hydroxybenzoic acid3. pindolol4. methylphenylsulphoxide5. benzylalcohol6. quinoxaline7. 1,4-dinitrobenzene8. phenacetin9. 1,2-dimethoxybenzene10. furosemide11. anisole12. methylbenzoate13. remacemide14. nimesulide15. ethylbenzoate16. diflunisalHydrophobic bindinginteractionsShape selectivityStrongWeak<strong>ACE</strong> <strong>Excel</strong> 2 C181245678910111612 14 1513P max= 309 barTarget AnalytesAnalytes differing in hydrophobicityPolar, moderately polar and nonpolar analytesUncharged acids and basesIonized acids or bases using ion-pairingZORBAX Eclipse1.8 XDB C18213456789101112 14 15 1613P max= 396 barRe<strong>com</strong>mended ApplicationsAnalytes differing in hydrophobicityHomologous <strong>com</strong>pounds differing by –CH2Ideal starting point for method development310, 11Waters ACQUITY1.7 BEH C1812456789121314 15 16P max= 478 bar3,4PhenomenexKinetex 1.7 C181,2567891110121314 1516P max= 446 bar012Minutes345Comparative data may not be representative of all applications.Please see p.10 for acknowledgement of trademarksFurther Information;An HPLC product brochure discussing <strong>ACE</strong> C18 and all<strong>ACE</strong> phases is available.Contact your distributor to request your copy or visitwww.ace-hplc.<strong>com</strong> for further details.In this example the <strong>ACE</strong> <strong>Excel</strong> C18 <strong>UHPLC</strong> column provides retentionand selectivity similar to the other C18 <strong>UHPLC</strong> columns (althoughthere may be slight selectivity differences between different C18phases). Under these conditions, these slight differences allow the <strong>ACE</strong><strong>Excel</strong> C18 to fully separate all 16 <strong>com</strong>ponents of interest.As with all <strong>ACE</strong> HPLC columns, <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns also deliverexcellent peak shape for your analytes. Additionally, owing to theoptimal 2µm particle size and a rigorous classification protocol, backpressure for all <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns is significantly lower thanfor these leading <strong>UHPLC</strong> columns packed with


C18-AR(C18 with integral Phenyl functionality)Figure 7: Leveraging the unique <strong>ACE</strong> ® <strong>Excel</strong> TM C18-AR selectivityApplication #1504 – Water Soluble Vitamins by <strong>UHPLC</strong>Mobile Phase: A = 20 mM KH 2PO 4, pH 2.7 andB = 20 mM KH 2PO 4, pH 2.7 in MeOH/H 2O (50:50 v/v)Gradient: 20 to 70% B in 5 minutesFlow Rate: 0.31 ml/minTemperature: 40°CDetection: UV, 205 nmColumn Dimensions: 50 x 2.1mm1. pyridoxine2. p-aminobenzoic acid3. pantothenic acid4. folic acid5. d-biotin6. cyanocobalamin7. riboflavinMechanisms ofSeparationπ-π interactionsDipole-dipole interactionsHydrophobic bindinginteractionsShape selectivityTarget AnalytesStrength ofInteractionStrongModerateStrongModerate<strong>ACE</strong> <strong>Excel</strong> 2 C18-AR<strong>ACE</strong> <strong>Excel</strong> 2 C181143 245,62 3567P max= 209 barP max= 216 barAnalytes with π bonding and conjugated systems7Analytes with electron delocalization and electronwithdrawinggroups, such as halogens, nitro groups,ketones, esters and acids4Analytes with different dipole momentsAnalytes differing in hydrophobicityPolar, moderately polar and nonpolar analytesZORBAX Eclipse1.8 XDB C18123567P max= 299 barUncharged acids and basesRe<strong>com</strong>mended Applications4Analytes differing in hydrophobicity, homologous<strong>com</strong>pounds differing by –CH 2StereoisomersWaters ACQUITY1.7 BEH C1812 3 576P max= 336 barSteroidsSubstituted aromatics4Sulphur containing <strong>com</strong>poundsSuitable for use in up to 100% aqueous mobilephase conditionsParticularly re<strong>com</strong>mended for applications where aC18 does not provide an adequate separationPhenomenexKinetex 1.7 C1812, 3567P max= 315 bar03MinutesComparative data may not be representative of all applications.Please see p.10 for acknowledgement of trademarks124 56This test illustrates that the leading C18 <strong>UHPLC</strong> column brands shownabove do not readily separate these water soluble vitamins under theconditions stated.Further Information;A product bulletin discussing the unique <strong>ACE</strong> C18-ARphase is now available.Contact your distributor to request your copy or visitwww.ace-hplc.<strong>com</strong> for further details.The additional mechanisms of separation provided by the <strong>ACE</strong><strong>Excel</strong> 2µm C18-AR generate a better separation for both peakpairs, with resolution significantly improved under these conditions.Optimisation of both column dimensions and evaluation conditions,to further reduce analysis time, is now possible.www.ace-hplc.<strong>com</strong><strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>7


C18-PFP(C18 with integral PFP functionality)Figure 8: Leveraging the unique <strong>ACE</strong> ® <strong>Excel</strong> TM C18-PFP selectivityApplication #1505 – Structural Isomers by <strong>UHPLC</strong>Mobile Phase: MeOH/H 2O (50:50 v/v)Flow Rate: 0.21 ml/minTemperature: 40 °CColumn Dimensions: 50 x 2.1mm1. 1,2,3-trimethoxybenzene2. 1,2-dimethoxybenzene3. 1,2,4-trimethoxybenzene4. methoxybenzene5. 1,3-dimethoxybenzene6. 1,3,5-trimethoxybenzene7. toluene136Mechanisms ofSeparationStrength ofInteraction<strong>ACE</strong> <strong>Excel</strong> 2 C18-PFP(fully porous ultra inert silica) 2457π-π interactionsStrongDipole-dipole interactionsStrongHydrophobic bindinginteractionsShape selectivityStrongStrong<strong>ACE</strong> <strong>Excel</strong> 2 C18(fully porous ultra inert silica)1, 2, 364, 57Target AnalytesAnalytes with π bondingAnalytes with electron donating groups, such asphenols, aromatic ethers and aminesAnalytes with proton donor groupsAnalytes with different dipole momentsWaters ACQUITY 1.7BEH C18(hybrid particle)1, 2, 34, 567Analytes differing in hydrophobicityPolar, moderately polar and nonpolar analytes1, 2, 3Uncharged acids and basesRe<strong>com</strong>mended ApplicationsAgilent Poroshell 2.7120 EC C18(superficially porous particle)4, 567Structural isomersSteroidsTaxanes1, 2, 3Substituted aromaticsAnalytes differing in hydrophobicity, homologous<strong>com</strong>pounds differing by –CH2Phenomenex Kinetex2.6 C18(core-shell particle)4, 567Suitable for use in up to 100% aqueous mobilephase conditionsParticularly re<strong>com</strong>mended for applications where aC18 does not provide an adequate separationFurther Information;A product bulletin discussing the unique <strong>ACE</strong> C18-PFPphase is now available.Contact your distributor to request your copy or visitwww.ace-hplc.<strong>com</strong> for further details.0Comparative data may not be representative of all applications.Please see p.10 for acknowledgement of trademarks2MinutesThis test illustrates that under these conditions, the leading C18 <strong>UHPLC</strong>column brands shown do not readily separate these structural isomersand that, irrespective of the nature of their particle construction, it isthe surface bonded phase effects that dominate. In particular, thehydrophobic binding interaction appears to offer no selectivity forseparating peaks 1, 2 and 3 and offers only poor resolution of peaks 4, 5and 6.The <strong>ACE</strong> <strong>Excel</strong> C18-PFP provides the additional selectivity needed toseparate the co-eluting analytes under these conditions. It is believedthat this additional selectivity is provided by a powerful <strong>com</strong>binationof the strong π-π and dipole-dipole interactions, coupled with thestrong shape selectivity and hydrophobic character offered by theunique C18-PFP phase.468<strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>www.ace-hplc.<strong>com</strong>


Phase Availability and SpecificationsPhase Functional Group Endcapped ParticleSize (µm)PoreSize (Å)SurfaceArea (m 2 /g)CarbonLoad (%)MaximumpH RangeUSPListing100% AqueousCompatibilityC18 Octadecyl (C18) Yes 2 a 100 300 15.5 1.5-10.0 b L1 -C18-AR C18 with integral Phenyl Yes 2 a 100 300 15.5 1.5-10.0 b L1 Yes CC18-PFP C18 with integral PFP Yes 2 a 100 300 14.3 1.5-10.0 b L1 Yes CC8 Octyl Yes 2 a 100 300 9.0 1.5-10.0 b L7 -C4 Butyl Yes 2 a 100 300 5.5 1.5-10.0 b L26 -CN Cyano Yes 2 a 100 300 5.5 2.0-8.0 b L10 -Phenyl Phenyl Yes 2 a 100 300 9.5 1.5-10.0 b L11 -AQ Proprietary Yes 2 a 100 300 14.0 1.5-10.0 b L1 Yes CSIL - - 2 a 100 300 - 1.5-8.0 b L3 -a <strong>ACE</strong> <strong>Excel</strong> <strong>UHPLC</strong> columns are also available with 3µm and 5µm particle sizes. <strong>ACE</strong> HPLC columns are also available with 3µm, 5µm and 10µm particle sizes.b For optimum column lifetime, a pH range of 2-8 is re<strong>com</strong>mended. To increase column lifetime at higher pH, organic buffers, low buffer concentrations, high % organic solvent and low temperaturesmust be considered. Further information is contained within “A Guide to HPLC and LC/MS Buffer Selection” by John Dolan – contact your distributor to request your FREE copy.c These <strong>ACE</strong> phases may be used with up to 100% aqueous mobile phase without retention loss c<strong>au</strong>sed by pore dewetting/phase collapse effects.<strong>ACE</strong> ® <strong>UHPLC</strong> Reusable Column Connector• Pressure rating >1700bar (>25000psi)• Compatible with all <strong>UHPLC</strong> systems• Compatible with all <strong>UHPLC</strong> column brands• Eliminates Poor Connections• Unique Reusable DesignWrenchFlat 1/4”(0.64cm)Reusable columnconnector with10-32 threads for1/16” OD TubingProprietary PEEKfilled cone<strong>ACE</strong> TorqueWrench EXL-TWFor further information and to receive a FREE productbulletin, please contact your local distributorAll <strong>UHPLC</strong> column brands require correct installation inorder to realise maximum column efficiency. To avoidproblems, the use of permanently swaged fittings is notre<strong>com</strong>mended, as these do not allow free movementbetween the tubing, fitting and column inlet on installation.This can result in a poorly connected column that showsunexpected peak tailing due to the introduction of extracolumn volume (dead volume) to the system. Alternatively,a leak at the inlet fitting connection may be observed.<strong>ACE</strong> <strong>UHPLC</strong> Column Connectors are reuseable and enable<strong>UHPLC</strong> columns to be correctly installed every time. Theirunique design ensures that they maintain pressure ratingwith repeated use, yet do not permanently swage onto theinlet tubing. To maximise the lifetime of the fitting, the useof an <strong>ACE</strong> Torque Wrench (p/n EXL-TW) is required.Standard <strong>ACE</strong> HPLC PEEK finger-tight connectors (p/n <strong>ACE</strong>-FT, pressure rated to 350bar/5000psi) may be used at theoutlet end of the <strong>UHPLC</strong> column, where pressure demandsare lower but a correct connection remains important.<strong>ACE</strong> <strong>Excel</strong> 2µm C18 <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm C18-AR <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm C18-PFP <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mmColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-101-0202UEXL-101-0203UEXL-101-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-109-0202UEXL-109-0203UEXL-109-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-1010-0202UEXL-1010-0203UEXL-1010-0246UEXL-101-0302UEXL-101-0303UEXL-101-0346UEXL-109-0302UEXL-109-0303UEXL-109-0346UEXL-1010-0302UEXL-1010-0303UEXL-1010-0346UEXL-101-3502UEXL-101-3503UEXL-101-3546UEXL-109-3502UEXL-109-3503UEXL-109-3546UEXL-1010-3502UEXL-1010-3503UEXL-1010-3546UEXL-101-0502UEXL-101-0503UEXL-101-0546UEXL-109-0502UEXL-109-0503UEXL-109-0546UEXL-1010-0502UEXL-1010-0503UEXL-1010-0546UEXL-101-7502UEXL-101-7503UEXL-101-7546UEXL-109-7502UEXL-109-7503UEXL-109-7546UEXL-1010-7502UEXL-1010-7503UEXL-1010-7546UEXL-101-1002UEXL-101-1003UEXL-101-1046UEXL-109-1002UEXL-109-1003UEXL-109-1046UEXL-1010-1002UEXL-1010-1003UEXL-1010-1046UEXL-101-1202UEXL-101-1203UEXL-101-1246UEXL-109-1202UEXL-109-1203UEXL-109-1246UEXL-1010-1202UEXL-1010-1203UEXL-1010-1246UEXL-101-1502UEXL-101-1503UEXL-101-1546UEXL-109-1502UEXL-109-1503UEXL-109-1546UEXL-1010-1502UEXL-1010-1503UEXL-1010-1546U<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC1 Also available as a 10pk p/n EXL-CC102 Torque wrench (p/n EXL-TW) is required3Starter kit available (p/n EXL-CCSK) containing 4x EXL-CC plus 1x EXL-TWwww.ace-hplc.<strong>com</strong><strong>ACE</strong> <strong>Excel</strong> <strong>Ultra</strong> <strong>Robust</strong> <strong>UHPLC</strong> <strong>Columns</strong>9


<strong>ACE</strong> <strong>Excel</strong> 2µm C8 <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm C4 <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm CN <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm Phenyl <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mm<strong>ACE</strong> <strong>Excel</strong> 2µm AQ <strong>Columns</strong>ColumnDiameter2.1mm3.0mm4.6mmColumnDiameter2.1mm3.0mm4.6mmColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-102-0202UEXL-102-0203UEXL-102-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-103-0202UEXL-103-0203UEXL-103-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-104-0202UEXL-104-0203UEXL-104-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-105-0202UEXL-105-0203UEXL-105-0246UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-106-0202UEXL-106-0203UEXL-106-0246UEXL-103-0302UEXL-103-0303UEXL-103-0346UEXL-104-0302UEXL-104-0303UEXL-104-0346UEXL-105-0302UEXL-105-0303UEXL-105-0346UEXL-106-0302UEXL-106-0303UEXL-106-0346UEXL-103-3502UEXL-103-3503UEXL-103-3546UEXL-104-3502UEXL-104-3503UEXL-104-3546UEXL-105-3502UEXL-105-3503UEXL-105-3546UEXL-106-3502UEXL-106-3503UEXL-106-3546UEXL-103-0502UEXL-103-0503UEXL-103-0546UEXL-104-0502UEXL-104-0503UEXL-104-0546UEXL-105-0502UEXL-105-0503UEXL-105-0546UEXL-106-0502UEXL-106-0503UEXL-106-0546UEXL-103-7502UEXL-103-7503UEXL-103-7546UEXL-104-7502UEXL-104-7503UEXL-104-7546UEXL-105-7502UEXL-105-7503UEXL-105-7546UEXL-106-7502UEXL-106-7503UEXL-106-7546UEXL-103-1002UEXL-103-1003UEXL-103-1046UEXL-104-1002UEXL-104-1003UEXL-104-1046UEXL-105-1002UEXL-105-1003UEXL-105-1046UEXL-106-1002UEXL-106-1003UEXL-106-1046UEXL-103-1202UEXL-103-1203UEXL-103-1246UEXL-104-1202UEXL-104-1203UEXL-104-1246UEXL-105-1202UEXL-105-1203UEXL-105-1246UEXL-106-1202UEXL-106-1203UEXL-106-1246UEXL-103-1502UEXL-103-1503UEXL-103-1546UEXL-104-1502UEXL-104-1503UEXL-104-1546UEXL-105-1502UEXL-105-1503UEXL-105-1546UEXL-106-1502UEXL-106-1503UEXL-106-1546UColumn Length20mm 30mm 35mm 50mm 75mm 100mm 125mm 150mmEXL-107-0202UEXL-107-0203UEXL-107-0246UEXL-102-0302UEXL-102-0303UEXL-102-0346U<strong>ACE</strong> <strong>Excel</strong> 2µm SIL <strong>Columns</strong>EXL-107-0302UEXL-107-0303UEXL-107-0346UEXL-102-3502UEXL-102-3503UEXL-102-3546UEXL-107-3502UEXL-107-3503UEXL-107-3546UEXL-102-0502UEXL-102-0503UEXL-102-0546UEXL-107-0502UEXL-107-0503UEXL-107-0546UEXL-102-7502UEXL-102-7503UEXL-102-7546UEXL-107-7502UEXL-107-7503UEXL-107-7546UEXL-102-1002UEXL-102-1003UEXL-102-1046UEXL-107-1002UEXL-107-1003UEXL-107-1046UEXL-102-1202UEXL-102-1203UEXL-102-1246UEXL-107-1202UEXL-107-1203UEXL-107-1246UEXL-102-1502UEXL-102-1503UEXL-102-1546UEXL-107-1502UEXL-107-1503UEXL-107-1546U<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC<strong>UHPLC</strong>Connector1, 2, 3EXL-CC1, 2, 3EXL-CC1, 2, 3EXL-CC1 Also available as a 10pk p/n EXL-CC102 Torque wrench (p/n EXL-TW) is required3Starter kit available (p/n EXL-CCSK) containing 4x EXL-CC plus 1x EXL-TW<strong>ACE</strong> ® is a registered trademark of Advanced Chromatography Technologies Limited. <strong>ACE</strong> <strong>Excel</strong> TM and HSC TM are trademarks of Advanced Chromatography Technologies Limited.UPLC, XBridge and ACQUITY are trademarks of Waters Corporation; ZORBAX, Eclipse, Poroshell and Infinity are trademarks of Agilent Technologies Inc.; Kinetex is atrademark of Phenomenex Inc.; UltiMate and Accela are trademarks of Thermo Fisher Scientific; Nexera and Prominence are trademarks of Shimadzu Corporation.Advanced Chromatography Technologies Limited has no affiliation with Waters Corporation, Agilent Technologies Inc., Phenomenex Inc., Thermo Fisher Scientific orShimadzu Corporation.<strong>ACE</strong> products are available through our international distributor networkAvailable from:<strong>Excel</strong>TM<strong>UHPLC</strong> <strong>Columns</strong>www.ace-hplc.<strong>com</strong>10Advanced Chromatography Technologies Limited, 1 Berry Street, Aberdeen, AB25 1HF, ScotlandTel: +44 (0) 1224 704 554 Fax: +44 (0) 1224 841 301 email: info@ace-hplc.<strong>com</strong> web: www.ace-hplc.<strong>com</strong>P1155-12-11-003-14000