12.07.2015 Views

100 mm

100 mm

100 mm

SHOW MORE
SHOW LESS
  • No tags were found...

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

ELECTRO-TECHNOLOGY FOR INDUSTRYDimensionsBEx(D)S 120D/EBEx(D)S 110D/E162145Ø 220Ø 1817 (3x)’d’ version: 263 ’e’ version: 275’d’ version: 313 ’e’ version: 326 3030Alarm tone tableBasic toneno.TonesStage 2 Stage 3 DIP switch settingsT2 T3 1 2 3 4 51 continuous tone <strong>100</strong>0 Hz, toxic gas alarm 31 11 0 0 0 0 02 alternating tone 800 Hz / <strong>100</strong>0 Hz, alternation every 0.25 s 17 5 1 0 0 0 03 slow whoop 500-1200 Hz, duration 3 s, gap 0.5 s 2 5 0 1 0 0 04 sweeping 800 Hz / <strong>100</strong>0 Hz, switching frequency 1 Hz 6 5 1 1 0 0 05 continuous tone 2400 Hz 3 27 0 0 1 0 06 sweeping 2400 Hz / 2900 Hz, switching frequency 7 Hz 7 5 1 0 1 0 07 sweeping 2400 Hz / 2900 Hz, switching frequency 1 Hz 10 5 0 1 1 0 08 siren 500 / 1200 / 500 Hz, duration 3 s 2 5 1 1 1 0 09 sawtooth 1200 Hz / 500 Hz within 1 Hz – DIN-TON, PFEER DIN 33909 15 2 0 0 0 1 010 alternating tone 2400 Hz / 2900 Hz, switching frequency 2 Hz 7 5 1 0 0 1 011 interrupted tone <strong>100</strong>0 Hz, switching frequency 1 Hz, general alarm 31 1 0 1 0 1 012 alternating tone 800 Hz / <strong>100</strong>0 Hz, switching frequency 0.875 Hz 4 5 1 1 0 1 013 interrupted tone 2400 Hz, switching frequency 1 Hz 15 5 0 0 1 1 014 interrupted tone 800 Hz, 0.25 s signal, 1 s gap 4 5 1 0 1 1 015 continuous tone 800 Hz 2 5 0 1 1 1 016 interrupted tone 660 Hz, 150 ms signal, 150 ms gap 18 5 1 1 1 1 017 alternating tone 544 Hz (<strong>100</strong> ms) / 440 Hz (400 ms) – NF S 32-001 2 27 0 0 0 0 118 interrupted tone 660 Hz, 1.8 s signal, 1.8 s gap 2 5 1 0 0 0 119 sweeping 1400 Hz –1600 Hz rising 1 s, falling 0.5 s – NF C 48-265 2 5 0 1 0 0 120 continuous tone 660 Hz 2 5 1 1 0 0 121 alternating tone 554 Hz / 440 Hz, switching frequency 1 Hz 2 5 0 0 1 0 122 interrupted tone 544 Hz, 0.875 s signal, 0.875 s gap 2 5 1 0 1 0 123 interrupted tone 800 Hz, switching frequency 2 Hz 6 5 0 1 1 0 124 sweeping 800 Hz / <strong>100</strong>0 Hz, switching frequency 50 Hz 29 5 1 1 1 0 125 sweeping 2400 Hz / 2900 Hz, switching frequency 50 Hz 29 5 0 0 0 1 126 simulated bell 2 1 1 0 0 1 127 continuous tone 554 Hz 26 5 0 1 0 1 128 continuous tone 440 Hz 2 5 1 1 0 1 129 sweeping 800 Hz / <strong>100</strong>0 Hz, switching frequency 7 Hz 7 5 0 0 1 1 130 interrupted tone 420 Hz, 0.625 s signal, 0.625 s gap, Australian alert 32 5 1 0 1 1 131 sweeping 1200 Hz / 500 Hz, switching frequency 1 Hz, ‘prepare to leave platform’ 11 1 0 1 1 1 1sweeping 500 Hz / 1200 Hz, 0.375 s signal, 0.375 s gap,32switching frequency 15 Hz, Australian evacuation alarmThe sounder can be set externally to the respective tones of stage 2 & 3. Tone 2 is preset.26 1 1 1 1 1 1AcousticEx signaling devicesOrdering detailsArticle numbers BExS 110D BExS 110E BExDS 110D BExDS 110ERated voltage 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 230 V AC320 80 10 0 000 320 80 80 0 000 320 82 10 0 000 320 82 80 0 000 320 75 10 0 000 320 85 10 0 000Article numbers BExS 120D BExS 120E BExDS 120D BExDS 120ERated voltage 230 V AC 24 V DC 230 V AC 24 V DC 230 V AC 230 V AC320 76 10 0 000 320 76 80 0 000 320 78 10 0 000 320 78 80 0 000 320 89 10 0 000 320 81 10 0 000Article numbers for other voltages on requestFurther technical information can be found on our website at www.pfannenberg.com223

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!