GR-961 - Simulator windowsWLF Files tabThe WLF Files tab includes these options:• WLF File Size LimitLimits the WLF file by size (as closely as possible) to the specified number of megabytes.If both size and time limits are specified, the most restrictive is used. Setting it to 0 resultsin no limit. Corresponding modelsim.ini variable is WLFSizeLimit (UM-514).• WLF File Time LimitLimits the WLF file by size (as closely as possible) to the specified amount of time. Ifboth time and size limits are specified, the most restrictive is used. Setting it to 0 resultsin no limit. Corresponding modelsim.ini variable is WLFTimeLimit (UM-514).• WLF AttributesSpecifies whether to compress WLF files and whether to delete the WLF file when thesimulation ends. You would typically only disable compression for troubleshootingpurposes. Corresponding modelsim.ini variables are WLFCompress (UM-514) forcompression and WLFDeleteOnQuit (UM-514) for WLF file deletion.• Design HierarchySpecifies whether to save all design hierarchy in the WLF file or only regions containinglogged signals. Corresponding modelsim.ini variable is WLFSaveAllRegions (UM-514).<strong>ModelSim</strong> <strong>SE</strong> <strong>GUI</strong> <strong>Reference</strong>